NetUP Streamer HDMI 8-24x v3. User manual
8
metal housing of device.
⚫
Grounding conductor must adopt copper conductor in order to reduce high frequency impedance,
and the grounding wire must be as thick and short as possible.
⚫
Users should make sure the 2 ends of grounding wire well electric conducted and be antirust.
⚫
It is prohibited to use any other device as part of grounding electric circuit
⚫
The area of the conduction between grounding wire and device’s frame should be no less than
25mm
2
.
2.2.4 Frame Grounding
All the machine frames should be connected with protective copper strip. The grounding wire should
be as short as possible and avoid circling. The area of the conduction between grounding wire and
grounding strip should be no less than 25mm
2
.
2.2.5 Device Grounding
Connecting the device’s grounding rod to frame’s grounding pole with copper wire.
2.3 Wire’s Connection
The grounding wire conductive screw is located at the right end of rear panel, and the power switch,
fuse, power supply socket is just beside, whose order goes like this, power switch is on the left, power
supply socket is on the right and the fuse is just between them.
⚫
Connecting Power Cord
User can insert one end into power supply socket, while insert the other end to AC power.
⚫
Connecting Grounding Wire
When the device solely connects to protective ground, it should adopt independent way, say,
share the same ground with other devices. When the device adopts united way, the grounding
resistance should be smaller than 1Ω.
Caution:
Before connecting power cord to Streamer HDMI 8-24 v3, user should set the power
switch to “OFF”
.