Operating instructions for

 

vibration measuring systems 

 

Vibro

Scanner

 VSI 

July 2020 

No. 1901E 

Page 1/19 

 

  

 

These operating instructions apply to:

 

vibration measuring systems  

series 

Vibro

Scanner

 VSI 

 

  

 

 

 

  

 

  

 

  

 

Summary of Contents for VibroScanner VSI

Page 1: ...Operating instructions for vibration measuring systems VibroScanner VSI July 2020 No 1901E Page 1 19 These operating instructions apply to vibration measuring systems series VibroScanner VSI...

Page 2: ...19 Please refer to the delivery note for the scope of delivery Check the packaging for possible transport damage In the event of damage to the packaging check the contents for completeness and possib...

Page 3: ...available at the time of printing and take our past experience to the best of our knowledge into account No claims can be derived from the information illustrations and descrip tions in these operatin...

Page 4: ...nal injuries CAUTION indicates a potentially dangerous situation Disregard of this notice can result in minor or moderate per sonal injuries NOTICE indicates potential material damage Disregard of thi...

Page 5: ...ning maintenance and troubleshooting of the VSI may only be performed by authorised qualified personnel All handling of the VSI is the responsibility of the operator DANGER Risk of electric shock due...

Page 6: ...he VSI 5 Cover adjacent live parts or fence them off DANGER Danger of electric shock due to high voltage Live parts can cause severe injuries or even death Lay electrical cables carefully Make sure th...

Page 7: ...tion terminal Voltage output 8 pin connection terminal Connection for sensor 4 pin connection terminal Dimensions mm w 114 h 76 d 31 Mounting On mounting rail according to DIN EN 50022 DIN EN 60715 or...

Page 8: ...1 preferably with union screw and integrated screw lock Dimensions mm 14 5 mm SW13 height sensor with plug 75 mm X Fastening thread M6 Maximum screw in depth 10 mm PIN assignment sensor cable Connecto...

Page 9: ...terminal sensor Connect sensor with the controller 8 Sensor with sensor cable Acquires values for acceleration and frequency on vibration systems Is connected to the control ler via the sensor cable T...

Page 10: ...rators or because interfering factors like vibrating or hitting compo nents or natural vibrations of an excited product overlay the excited vibra tion To describe a harmonic vibration three parameters...

Page 11: ...ited to ascertain the actual effect a vibration is having on a machine part or product over a longer period of time Random vibration wave forms can be described mathematically as super position of sev...

Page 12: ...one frequency which dominates the system to be measured The relevant period is ascertained between two points of time in a row where the value of the oscillating quantity reaches its maxi mum or mini...

Page 13: ...safe and technically disposable point of view and is therefore recyclable The return of packaging to the material cycle conserves raw materials and reduces the amount of waste Store the VSI in a dry...

Page 14: ...age output PIN 1 GND Ground frequency PIN 2 Frequency frequency PIN 3 GND Ground acceleration PIN 4 Acceleration Acceleration PIN 5 GND Ground stroke vibration ampli tude PIN 6 Stroke Stroke vibration...

Page 15: ...on regulations into account The operator is responsible for the proper condition of the system Carry out the following measures before start up 1 Check the mains voltage and the grid feed in 2 Check t...

Page 16: ...8 g 11 12 g Switch 5 6 binary coded Measuring range frequency 00 35 Hz 01 75 Hz 10 150 Hz 11 300 Hz Indicated values symbols Description F Frequency Hz Harmonic sinusoidal vibration Non harmonic sinu...

Page 17: ...ety from page 5 on Maintenance of the VSI must be carried out as follows Interval Action Monthly Check cables Every 6 month Check proper condition of connecting cables and plugs At least every 4 years...

Page 18: ...s not firmly fixed to the system to be measured or detaches repeatedly from the measuring surface dur ing the measurement Fasten the sensor correctly The sensor must be firmly attached to the measurin...

Page 19: ...he electrical installation must be installed by an authorised electrician This specialist must be familiar with the protec tive measures Defective parts must be replaced by parts of the same type If y...