NV-202P Long Reach Ethernet Extender with PoE User’s Manual Ver. A4
31
3. Symptom:
VDSL Link cannot be established.
Cause:
VDSL setting failure or phone cable length is over the specification limit.
Solution:
3.1 Please make sure that the phone wire must be connected between NV-202P(CO) and
NV-202(CPE) when both are power on. NV-202P(CO) will do link speed function depending on
phone wire length, therefore if NV-202P(CO) can’t detect NV-202(CPE) over phone wire while
both power on, this will cause the link to fail.
3.2 Please check the phone wire, we recommend use 24 gauge with twisted pair and without rust,
and the length is not over 3 km.
3.3 Please check the correct Dip Switch setting. (CO: PIN1 ON, CPE: PIN1 OFF)
3.4 Please reinsert power adapter when changing cable length or link time over 3 minutes.
Note:
Phone wire must meet CAT 3 standard or above and
without clustering
, otherwise will cause more
cross talk issue to reduce DSL power driver.
4. Problem:
What is VDSL2?
Answer:
Very-high-speed digital subscriber line 2 (VDSL2) is an access technology that exploits the existing
infrastructure of copper wires that were originally deployed for traditional telephone service. It can
be deployed from central offices, from fiber-optic connected cabinets located near the customer
premises, or within buildings. It was defined in standard ITU-T G.993.2 finalized in 2005.
VDSL2 was the newest and most advanced standard of digital subscriber line (DSL) broadband
wireline communications. Designed to support the wide deployment of triple play services such as
voice, video, data, high definition television (HDTV) and interactive gaming, VDSL2 was intended to
enable operators and carriers to gradually, flexibly, and cost-efficiently upgrade existing xDSL