N
V
-
2
0
D
S
L
B
r
i
d
g
e
w
t
h
I
P
c
U
E
R
’
M
A
Page 1: ...V V V 2 2 20 0 02 2 2 V V VD D DS S SL L L2 2 2 B B Br r ri i id d dg g ge e e w w wi i it t th h h D D DI I IP P P S S Sw w wi i it t tc c ch h h U U US S SE E ER R R S S S M M MA A AN N NU U UA A AL...
Page 2: ...hts of any third party Statement of Conditions In the interest of improving internal design operational function and or reliability NETSYS reserves the right to make changes to the products described...
Page 3: ...etric in VDSL2 Profile 30a solution The NV 202 also supports both central office CO and customer premises equipment CPE modes selectable through DIP Switch Since VDSL2 has the characteristic of higher...
Page 4: ...e power cord DO NOT install nor use your device during a thunderstorm There may be a remote risk of electric shock from lightning DO NOT expose your device to dampness dust or corrosive liquids DO NOT...
Page 5: ...L2 SOLUTION 2 SAFETY WARNINGS 3 CHAPTER 1 UNPACKING INFORMATION 6 1 1 Check List 6 CHAPTER 2 INSTALLING THE BRIDGE 7 2 1 Hardware Installation 7 2 2 Pre installation Requirements 7 2 3 General Rules 8...
Page 6: ...t Panel 14 3 2 Front Indicators 15 3 3 Rear Panel 16 APPENDIX A CABLE REQUIREMENTS 22 APPENDIX B PRODUCT SPECIFICATION 24 APPENDIX C DIN RAIL MOUNT INSTALLATION 26 APPENDIX D TROUBLESHOOTING 27 APPEND...
Page 7: ...e is a need to return for repair 2 If the product has any issue please contact your local vendor 3 Do not use sub standard power supply Before connecting the power supply to the device be sure to chec...
Page 8: ...uding power requirements sufficient physical space and proximity to other network devices that are to be connected Verify the following installation requirements Power requirements DC 12V power The br...
Page 9: ...end node VDSL2 Port RJ 11 All network connections to the RJ 11port must use 24 26 gauge with twisted pair phone wiring We do not recommend the use of the telephone line 28 gauge or above The RJ 11 con...
Page 10: ...ust support auto negotiation or 10Base T or 100Base TX unless they will always operate at half duplex Use any of the Ethernet ports to connect to devices such as Monitor system Server Switch bridge or...
Page 11: ...me time Either RJ 11 port is connected or terminal block is connected using straight connection Figure 2 4 or cross over connection Figure 2 5 Figure 2 4 NV 202 line ports straight connection Figure 2...
Page 12: ...333 feet 2 We advise using Category 5 7 UTP STP cables for Cable bridge or Bridge connections to avoid any confusion or inconvenience in the future when you attached to high bandwidth devices 3 Use 2...
Page 13: ...oss existing phone wiring It is easy to use which do not requires installation of additional wiring Every modular phone jack in the home can become a port on the LAN Networking devices can be installe...
Page 14: ...202 VDSL2 Bridge with DIP Switch USER S MANUAL Ver A4 13 Chapter 3 Hardware Description This section describes the important parts of the bridge It features the front panel and rear panel NV 202 Outwa...
Page 15: ...el it is easy to determine if it has Ethernet signal from its RJ 45 port and if there is vdsl line signal on RJ 11 port And the table shows the description Table 3 1 Table 3 1 Description of the bridg...
Page 16: ...een On Steady Indicate the VDSL2 bridge is running at CO Master mode CPE Remote Side CPE LED Green On Steady Indicate the VDSL2 bridge is running at CPE Slave mode On Steady The Internet or network co...
Page 17: ...ion Power DC Power Jack External Power Adapter Input AC 85 240Volts 50 60Hz Output DC 12V 1A DIP Switch 4 Pins DIP Switch Provide 4 selectable transmission modes Ground Earthing strip Please connect t...
Page 18: ...tch configuration Table 3 4 Table 3 4 DIP Switch Configuration Pin 1 Pin 2 Pin 3 Pin 4 On OFF CO CPE Mode Band SNRM Interleave INP On CO Mode High Band 9db 8ms INP 2 Off CPE Mode Low band 6db 1ms INP...
Page 19: ...Hz It can pass through ISDN spectrum 0 499KHz are empty OFF Low Band Mode 300KHz to 30MHz the NV 202 will auto detect the cable length and auto choice speed mode PIN3 When SNR margin is selected the s...
Page 20: ...hem up into smaller bits and then rearranging them so that once contiguous data is now spaced further apart into a non continuous stream Data packets are re assembled by your bridge The diagram below...
Page 21: ...NRM Signal to Noise Ratio Margin It s very similar to a conversation at a party and it s dealt with in the same way we naturally account for both distance from the other person and the amount of backg...
Page 22: ...vices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point Note Do not run signal or communications wiring and power wiring through the sa...
Page 23: ...t pins The Ethernet standard uses pins 1 2 3 and 6 for data transmission purposes Table A 1 Table A 1 RJ 45 Ethernet Connector Pin Assignments MDI MDI X PIN Signal Media Dependant interface Signal Med...
Page 24: ...NV 202 VDSL2 Bridge with DIP Switch USER S MANUAL Ver A4 23 Figure A 2 Pin Assignments and Wiring for an RJ 45 Straight Through Cable Figure A 3 Pin Assignments and Wiring for an RJ 45 Crossover Cable...
Page 25: ...and Interleave mode selectable through CO side DIP switch DIP switch with CO and CPE mode selectable Supports long packet size up to 1536 bytes Supports Surge protection Supports wall mounting Suppor...
Page 26: ...tor LED 1 x CPE Mode indicator LED VDSL2 Line Code Discrete multitone DMT modulation VDSL 2Transmission Mode Packet Transfer Mode PTM Typical Power Consumption 5 W Power Requirement Input Voltage 12VD...
Page 27: ...e refer to install the DIN RAIL as following step 1 Install the DIN Rail mounting plate to the NV 202 Figure C 1 2 Please use the suitable DIN Rail to install please refer to the dimensions of the DIN...
Page 28: ...If these measures fail to resolve the problem have the unit power supply replaced by a qualified distributor 2 Symptom Link indicator does not light up green after making a connection Cause Network i...
Page 29: ...k time over 3 minutes Note Phone wire must meet CAT 3 standard or above and without clustering otherwise will cause more cross talk issue to reduce DSL power driver 4 Question What is VDSL2 Answer Ver...
Page 30: ...stream on twisted pairs using a bandwidth up to 30 MHz VDSL2 deteriorates quickly from a theoretical maximum of 250 Mbit s at source to 100 Mbit s at 0 5 km 1 600 ft and 50 Mbit s at 1 km 3 300 ft but...
Page 31: ...ions the SNR will probably cause a reduction in data speed because of frequent errors that require the source transmitting computer or terminal to resend some packets of data SNR measures the quality...
Page 32: ...ent Packet generator if you don t have Smartbit we recommend test that by IPERF program and TCP window size must be setted max 64k the parameter as iperf c server IP address i 1 t 50 w 65535 for clien...
Page 33: ...ning properly Transmission Mode The default method of selecting the transmission mode for RJ 45 ports is 10 100 Mbps ETHERNET for RJ 11 port are auto negotiation VDSL Therefore if the Link signal is d...
Page 34: ...istances and other physical aspects of the installation do not exceed recommendations System Integrity As a last resort verify the switch integrity with a power on reset Turn the power to the switch o...
Page 35: ...nt off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equi...
Page 36: ...These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment can generate use and radiate radio fre...
Page 37: ...nt and human health as a result of the presence of hazardous substances in electrical and electronic equipment end users of electrical and electronic equipment should understand the meaning of the cro...
Page 38: ...V 202 CO Mode Pin1 ON VDSL2 Bridge CPE Mode x 1 NV 202 CPE Mode Pin1 OFF Operation System Windows XP Ethernet Cable Cat 5e UTP RJ 45 8P8C Ethernet Cable Phone Wire 24 AWG simulator card Room temperatu...
Page 39: ...0 28 58 26 87 2000 2 50 14 92 200 100 100 900 24 12 25 45 2200 2 05 13 36 300 100 100 1000 23 04 22 03 2400 1 94 11 52 400 72 91 73 3 1200 16 81 16 82 2600 1 80 9 01 500 57 09 55 79 1400 12 33 16 53 2...
Page 40: ...which contain defects which are in any way attributable to improper installation or to alteration or repairs made or performed by any person not under control of the original owner The above warranty...
Page 41: ...NV 202 VDSL2 Bridge with DIP Switch USER S MANUAL Ver A4 40 Chinese SJ T 11364 2006 Pb Hg Cd Cr VI PBB PBDE SJ T 11364 2006 SJ T 11364 2006...