NetPing 886A02 Manual Download Page 4

[Docs] NetPing Converter 0-20mA, 886A02 -[ENG] [886A02] Introduction

[ENG] [886A02] Introduction

                             – 



[ENG] [886A02] Introduction

This manual will help you get acquainted with the specialities and features of the

 NetPing Converter 0-20mA, 

886A02 model

, get an idea of its functionality and technical characteristics and prepare the sensor for operation.

A User Guide is designed for network administrators and users, who set up or operate a device. To work with a 
device properly, a user must have an idea about the principles of building and functioning of local networks as well 
as possess the next knowledge and skills:

Basic knowledge in the area of local and global networks;

Basic knowledge in the area of architecture and principles of work of TCP/IP networks;
Basic knowledge in the area of architecture and principles of work of Ethernet networks. 

Summary of Contents for 886A02

Page 1: ... Docs NetPing Converter 0 20mA 886A02 ...

Page 2: ... and Indications Elements 8 Front Panel 8 Back Panel 9 ENG 886A02 Installation and Connection 10 ENG 886A02 Loop Sensor Connection to the Converter 12 Functions of the converter s connectors 12 General information 12 The example of connection 13 Equivalent circuit scheme of a meter input 14 ENG 886A01 Delivery Package 15 ENG 886A02 Warranty 16 ENG 886A02 Operating and storage conditions 17 ENG 886...

Page 3: ... Docs NetPing Converter 0 20mA 886A02 ...

Page 4: ...nsor for operation A User Guide is designed for network administrators and users who set up or operate a device To work with a device properly a user must have an idea about the principles of building and functioning of local networks as well as possess the next knowledge and skills Basic knowledge in the area of local and global networks Basic knowledge in the area of architecture and principles ...

Page 5: ...respond to expectations of a user and his her opinion about where and how to use all the above All copyrights on supplied devices described in this User Guide as well as firmware and software of devices and this User Guide belong to NetPing global Ltd Сopying replication and translation of this user guide to other languages are not allowed without a prior written permission of a rightholder Copyin...

Page 6: ...easurement range 0 29 999 Ohm 3 Current sensor connection type High side positive polarity Low side negative polarity drop on the intrumental shunt up to 1V Loop power supply Built in 12V with short circuit current 100mA 24V with output current up to 30 mA Power supply From the host device Hot connection to the host is not provided it is allowed to reboot the host during the hot connection Operati...

Page 7: ... Docs NetPing Converter 0 20mA 886A02 ENG 886A02 Overview and Main Features ENG 886A02 Overview and Main Features Sensor Specifications Values Sensor weight 70 g ...

Page 8: ...nectors and Indications Elements ENG 886A02 Connectors and Indications Elements ENG 886A02 Connectors and Indications Elements Front Panel Element Function GND Common connector RS RS Current loop connectors 12V Power connector 12V 24V Power connector 24V ...

Page 9: ... Converter 0 20mA 886A02 ENG 886A02 Connectors and Indications Elements ENG 886A02 Connectors and Indications Elements Back Panel Element Function LP Loop power indicator PWR Sensor power indicator 1W Host connector ...

Page 10: ...er to direct sunlight Do not install the converter near heat sources Do not open the converter case Avoid getting liquid on the converter particularly on the connectors The sequence of connection Step 1 Remove the converter 886A02 from its packaging Put it onto the place you need Step 2 Connect the converter to the 1 wire port of the device or through an extension splitter to which you are connect...

Page 11: ...er 0 20mA 886A02 ENG 886A02 Installation and Connection ENG 886A02 Installation and Connection The configuration of the sensor and notifications you can see in a description of a built in firmware on a connected host device ...

Page 12: ...voltage on RS and calculate the resistance based on the obtained values There are two possible schemes of connection Low side measuring only the flowing current Voltage is not measured resistance is not calculated The loop is closer to the power connector the shunt is on the GND side High side measuring the flowing current and voltage calculation of resistance Voltage measurement error is up to 60...

Page 13: ...e scheme Thus with the middle position of the resistor handle 23 900 mV 4 86 mA 4918 Ohm At the ultimate right position 24 000 mV 2 4 mA 10 000 Ohm It is possible to measure voltage 0 30V by connecting the of the power supply to the RS connector and connecting the GND of the power supply and the converter Attention In case of a short circuit at the output of the current loop power of the converter...

Page 14: ...rter 0 20mA 886A02 ENG 886A02 Loop Sensor Connection to the Converter ENG 886A02 Loop Sensor Connection to the Converter If you connect it this way only voltage will be measured Equivalent circuit scheme of a meter input ...

Page 15: ...e ENG 886A01 Delivery Package The delivery package consists of a NetPing Converter with the analogue interface 0 20mA 886A02 model 1 pc a Quick Start Guide brochure 1 pc a flat connecting cable 6 wire AWG24 with RJ12 connectors at the ends 2 meters 1 pc a terminal block STK 15EDG K 3 5 5P 1 pc ...

Page 16: ...for the customer Only the errors that block normal use of the device at conditions and for performing functions described in this User Guide are a subject to mandatory fix This warranty does not apply to cases when defects appear because of a misuse of a device any modifications of a device without a written permission of the manufacturer opening up a device a warranty sticker on the case of a dev...

Page 17: ... up to 50 С without moisture condensation at normal humidity The converter should be protected from direct sunlight and moisture The converter design provides reliable trouble free operation during a long time without the necessity of special maintenance The storage of converters is carried out at temperatures from 40 С up to 70 С The content of dust vapors of acids and alkalis corrosive gases and...

Page 18: ...ocuments and Weblinks ENG 886A02 Additional Documents and Weblinks The page of the converter 886А02 http www netpingdevice com products 886a02 Manufacturer s website http www netpingdevice com Technical support contacts http www netpingdevice com support Phone 886 2 23121582 E mail support netpingdevice com ...

Reviews: