Netgenium AUG3201-IP Configuration Manual Download Page 18

genium

Net

AUG3201-IP Config Guide

© Copyright Netgenium Systems 2017

Page         18

  

This chapter describes the utilities and features available with the AUG3201-IP. 

 

      

Audio Files
  

Navigate to: Utilities>Audio Files

  

Audio files can be stored on in the onboard flash file system. The stored files         

   can be triggered to play by a local event using Flex IO or by an IP event  

   received over the network.
   Before attempting to upload any files to the speaker, ensure that the flash file      

   system is installed. The flash file system is stored on a Micro SD flash card. 

    

 

  

Utilities

Summary of Contents for AUG3201-IP

Page 1: ...Netgenium AUG3201 IP Configuration Guide ver 5 x ...

Page 2: ...MANUAL WERE ACCURATE AT THE TIME OF WRITING BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS IN NO EVENT SHALL NETGENIUM SYSTEMS BE LIABLE FOR ANY INDIRECT SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES INCLUDING WITHOUT LIMITATION LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL Copyr...

Page 3: ... gateway in the address bar Each unit is pre configured with a default IP address of 10 100 1 173 when it leaves the factory The default username and password are as follows Username netgenium Password netgenium The home page provides basic information on the unit such as software version serial number etc Navigation around the menu structure is via the tabs shown at the top of the home page Each ...

Page 4: ...evice usually a description of the location Network P Address IP address of the device Network Mask Subnet Mask of the device Default Gateway Default Gateway for the device Netgenium Primary PolicyServer The IP Address of the primary PolicyServer Netgenium Secondary PolicyServer The IP Address of the secondary PolicyServer Registration Mode Autonomous or registered with PolicyServer Registration S...

Page 5: ...on is clicked Set Manually Enter the time and date in the textboxes provided and click the Apply button Use NTP With this option enabled the controller will synchronize its time and date with an NTP server every 5 minutes Enter the IP Address of the NTP server and click the Apply button If the controller is configured to register with PolicyServer the unit will automatically be synchronised with P...

Page 6: ...ault settings are Username netgenium Password netgenium To add a new user account enter the username and password and click the Update button To remove an account highlight the name to delete and click the Delete button System Navigate to Setup System The system password is used to authenticate requests between PolicyServer and the end devices The default setting is netgenium ...

Page 7: ...genium Net AUG3201 IP Config Guide Copyright Netgenium Systems 2017 Page 7 Gateway Audio Out Navigate to Gateway The Gateway tab gives access to General gateway settings and audio volume settings ...

Page 8: ...e a PoE power source TCP Audio Port Not used in Ver 5 Audio Priority The gateway supports 9 audio priorities 1 9 1 is the lowest and 9 is the highest The default priority is 5 Each priority level can be assigned its own volume setting If a gateway is making an announcement and it receives an announcement at the same or lower priority it will be ignored An announcement with a higher priority will t...

Page 9: ...y Audio In To configure an analogue audio input into the unit 1 Tick the Enable Audio Input and select the type of input used Line In or Microphone 2 Use the Input Gain options to set the optimal gain setting for the input you are using 3 Connect the input device to the gateway and adjust the input gain ...

Page 10: ...icrophone In Microphone In provides a low level analogue audio input to the gateway An input voltage of approximately 1 mV is required Signal Signal and Chassis GND terminals are provided for balanced and un balanced signals Line Out Line Out provides a low level analogue audio output from the gateway A signal output voltage of approximately 1 V is supplied This output is suitable for an input to ...

Page 11: ... using the Trigger Level slider Once this level has been exceeded by the amplitude of the audio the trigger remains active Resetting the trigger requires the amplitude of the audio input to remain below the Trigger Level for a predetermined number of seconds This can be configured by setting the Vox Dwell parameter To set up Vox 1 Tick the Enable Vox 2 Select what you want the gateway to do when t...

Page 12: ...ggered by a volts free contact relay contacts for example All Flex Inputs are disabled by default To configure a Flex Input 1 Enable the desired Flex Input 2 Select the normal state of the contacts N O or N C 3 Select the desired gateway operation when the inputs change state This selection is made using the Operation list box 4 Ensure the Flex Input is wired correctly 5 Click Apply ...

Page 13: ...y a relay The output is turned on as a result of a pre selected gateway condition The output can also be controlled by PolicyServer All Flex Outputs are disabled by default To configure a Flex Output 1 Enable the desired Flex Output by selecting the gateway condition that activates the output from the Operation list box 2 Set the duration the output is active Momentary or Whilst Trigger Active 3 E...

Page 14: ...switches Flex Outputs Flex I O Outputs provide a switched VE 12Vdc voltage when active Each output requires a 2 wire connection and is typically used to energise a relay unit to provide a zero volts input into another system The illustration above shows a switched negative supply provided by Flex Output 1 If you intend to power another unit using a Flex Output take care to ensure that the overall ...

Page 15: ...opriety call control protocols This allows the gateway to be dialed from a telephone handset and a live announcement made A priority level for telephony based announcements can be configured If Delayed Announcement is enabled the announcement will be stored in gateway memory and played when the call is terminated Before configuring SIP or Skinny parameters the call control protocol must be selecte...

Page 16: ...Address 1 2 Select how incoming calls will be handled dropped or auto answer 3 Select the phone type to emulate The 7902 is a single line extension The 7961 has multiple lines 4 Click Apply If auto registration is enabled on the Call manager server the gateway will attempt to register with the server This page does not auto refresh Click the Apply button to monitor the registration status ...

Page 17: ...ccount 2 Enter the Password for the account 3 Enter the Display Name 4 If you are registering with a SIP server Select Enable SIP Registration checkbox and set the Registration Interval 5 Select how you wish to handle incoming calls 6 Set the audio priority for telephony 7 Call Timeout is the maximum duration of a SIP call is seconds 8 Click Apply ...

Page 18: ...te to Utilities Audio Files Audio files can be stored on in the onboard flash file system The stored files can be triggered to play by a local event using Flex IO or by an IP event received over the network Before attempting to upload any files to the speaker ensure that the flash file system is installed The flash file system is stored on a Micro SD flash card 2 Utilities ...

Page 19: ...Ensure that the audio file is WAV format 2 Click the Choose File button and select the file 3 Click the Upload button To delete an audio file 1 Select the files to be deleted by clicking on the checkboxes as shown below 2 Click the Delete Selected button The Micro SD card has been detected with a valid flash file format The Micro SD card has NOT been detected The Micro SD card has been detected Th...

Page 20: ...nge the audio announcement played if the number of play requests exceeds pre defined limits To enable this feature Navigate to Utilities Escalations 1 Enable the Escalations feature 2 Set the play frequency and time parameters 3 Select the audio file to be played when the escalation parameters are exceeded 4 Click Apply ...

Page 21: ...specifying a time frame in seconds it is possible to prevent an announcement from being constantly broadcast due to multiple trigger conditions For an example a value of 30 seconds will result in the announcement being played a maximum of once in 30 seconds To enable this feature Navigate to Utilities Exceptions 1 Enable the feature 2 Set the time parameter 3 Click Apply ...

Page 22: ...ion with the Vox feature to send an audio broadcast to a pre defined group of speakers The work flow to create a Speaker Group is as follows 1 Create a new group by a Enter a name for the group b Assign a default audio priority for the group c Assign a Multicast IP address to be used by the group d Assign a UDP port to be used by the audio e Click Add New ...

Page 23: ...enium Systems 2017 Page 23 2 Edit the group and add the IP addresses of the speakers the group will contain To do this a Select the group from the drop down list and click Edit b Add the IP addresses of the speakers 1 per line c Click the Apply button ...

Page 24: ...ggered To setup a new Event Navigate to Utilities IP Events 1 Enter a name for the new event 2 Enter a target IP address and tcp udp port for the event 3 Click Apply The event must now be edited and the event data added 4 Select the newly added event from the dropdown listbox and click Edit 5 Add the event text to the textbox and click the Apply button ...

Page 25: ...genium Net AUG3201 IP Config Guide Copyright Netgenium Systems 2017 Page 25 Immix Not available in ver 5 ...

Page 26: ...found under the Maintenance tab in the web interface The feature displays the current status of the device and allows diagnostics to be performed from a web browser Status Navigate to Maintenance Status The Status page shows the current status of the unit The page does not auto refresh in a browser 3 Maintenance Diagnostics ...

Page 27: ...enance Diagnostics Audio files stored in flash memory can be used to test the audio function of the device To perform an audio test Select an audio file from the dropdown list and click the play button The devices Flex IO Outputs can be turned on and off manually using the diagnostic button for each output ...

Page 28: ...ne log used for fault diagnostics Each log entry is time and date stamped using the units system time This log is memory resident and will be lost when the unit is rebooted The log is intended as an aid to fault diagnosis and not as a event archive The Syslog feature if configured will send the log entries to a Syslog server on your network ...

Page 29: ...ght Netgenium Systems 2017 Page 29 Syslog Navigate to Maintenance Syslog To send log entries to a Syslog server on your network 1 Enable syslog 2 Enter the Syslog server IP address 3 Enter the udp port the Syslog server is using 4 Click Apply ...

Page 30: ...ick the Reboot button or power cycle the device Update Firmware The remote update feature is available on software version 5 7 1 onwards The update process is completed using the web browser interface Google Chrome is recommended Before you start you will need the new image with a ngx file extension on the hard disk of your computer Browse to the IP address of the device you want to upgrade Naviga...

Page 31: ... computer 3 Click Apply 4 Click the Upload To Store button The new file will be uploaded to the New Image Store of the device 5 Click the the Upgrade To New Image button The speaker will upgrade and reboot Ensure that the device stays powered on and connected to the network during this entire process If this device is reset during this process it may not recover ...

Page 32: ...Netgenium Systems Technology House 5 Walton Road Pattinson North Washington Tyne Wear NE38 8QE ...

Reviews: