Netgenium ALK3701-IP Configuration Manual Download Page 22

 

 

Configuration 

21 

 

Features 

Navigate to: Lock>Features 

 

 

 

The ALK370x family of lock controllers support a number of audio, visual and report 
features that can be enabled upon certain events at the door. The features are 
described below: 

 

Door Left Open. 

Providing the state of the door is monitored two events can be used to alert the fact 
a door has been left open. The audio/visual alert will make the attached card 
readers flash and beep when the door is open for more than the number of seconds 
entered in the Open Timer textbox. To disable the audio alert, un-tick the Enable 
Audio Indication checkbox. 

A second option is to send an alert to PolicyServer, this can be configured instead of 
the audio/visual alert, or as a second stage in the procedure. To enable this alert, 
enter the number of seconds to elapse before the alert is sent (0 to disable). 

 

 

 

Summary of Contents for ALK3701-IP

Page 1: ...ALK3701 IP Configuration Guide...

Page 2: ...PRESENTED WITHOUT WARRANTY OF ANY KIND USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS IN NO EVENT SHALL NETGENIUM SYSTEMS BE LIABLE FOR ANY INDIRECT SPECIAL CONSEQUENTIAL OR...

Page 3: ...2 Contents Preface Chapter 1 Overview 3 Chapter 2 Installation 5 Chapter 3 Maintenance Diagnostics 16 Index 21...

Page 4: ...ventions page 2 Purpose The Netgenium ALK3701 IP Manual provides information about installing and configuring the Netgenium ALK3701 IP lock controller Audience The Netgenium ALK3701 IP Manual is writt...

Page 5: ...s document uses the following conventions BOLD ORANGE font is used to show Navigation steps to configure a feature BOLD RED font is used to indicate a button or hyperlink BLUE font is used to indicate...

Page 6: ...readers up to a max power budget of 800mA 12Vdc The controller has 1 RJ 45 style socket for connection to the LAN The LAN interface is a standard 10 100 network connection The screw terminals enable...

Page 7: ...via the software options Restore Factory Default Configuration ALK3701 IP configuration can be restored to factory defaults by pressing the Default button this will cause the System Status LED to fla...

Page 8: ...g kit containing 4 x wall plugs 2 x 25mm screws top fixing 2 x 50mm screws bottom fixing To fix the controller to the wall Use the template supplied to drill 4 holes Insert the wall plugs into the hol...

Page 9: ...Installation 8...

Page 10: ...on of the most common I O components the lock hardware card readers RTX switch and emergency break glass The unit has no support for card readers Application notes containing are available for each su...

Page 11: ...able as both fail secure and fail safe Both types require 12Vdc to operate however a fail secure door strike is locked when no power is present and requires 12Vdc to release the mechanism a fail safe...

Page 12: ...is feature senses whether the door is open or closed and toggles the relay contacts The controller can then be configured in software to react to the status of the door The door contacts are connected...

Page 13: ...s to close for the gates to open These contacts are provided across the N O1 and CM1 terminals of the controller Alternately if the gate mechanism requires a N C set of contacts to open for the gates...

Page 14: ...e RTX switch is connected to the controller via the 0V and any of the Flex I O connectors I9 Flex I O 1 I10 Flex I O 2 I11 Flex I O 3 or I12 Flex I O 4 The controller will support both N O press to ma...

Page 15: ...The connections of the EBG vary depending upon the type used The wiring from the ALK3701 IP is as follows 12V is connected to the common or equivalent of the EBG The N C or equivalent of the EBG is th...

Page 16: ...in the address bar Each unit is pre configured with a default IP address of 10 100 1 175 when it leaves the factory The default username and password are as follows Username Netgenium Password netgen...

Page 17: ...f the location Network IP Address IP address of the device Network Mask Subnet Mask of the device Default Gateway Default Gateway for the device Netgenium Primary PolicyServer The IP Address of the pr...

Page 18: ...Secondary DNS Network Port Link Configuration Set the speed and duplex settings of the network interface If you have changed the IP address of the controller you will lose the connection to it Open an...

Page 19: ...n is clicked Set Manually Enter the time and date in the textboxes provided and click the Apply button Use NTP With this option enabled the controller will synchronize its time and date with an NTP se...

Page 20: ...netgenium Password netgenium To add a new user account enter the username and password and click the Update button To remove an account highlight the name to delete and click the Delete button System...

Page 21: ...pdown list The options are Magnetic Lock Fail Safe Door Strike Fail Safe Door Strike Fail Secure Clean Relay Contacts If one or more Request To Exit RTX switches are fitted the behavior of the control...

Page 22: ...t the fact a door has been left open The audio visual alert will make the attached card readers flash and beep when the door is open for more than the number of seconds entered in the Open Timer textb...

Page 23: ...e lock controller has released the locking mechanism Therefore this alert is only available when the door state is being monitored Three alerts are available audio attached reader s beep visual attach...

Page 24: ...onfigured to unlock the door and notify devices on the network or the alert Auxiliary Report sends an Auxiliary Report to PolicyServer which can be configured to react upon receipt Door Monitor connec...

Page 25: ...heckbox and nominate either normally open n o or normally closed n c depending upon the contacts you are connecting to Finally select the function the input is to perform from the Operation dropdown l...

Page 26: ...e The database contains the IP addresses of the devices to be notified in the event of fire alarm activation The database must be populated manually To add an entry to the Fire Device Database enter t...

Page 27: ...the IP addresses of the instances of Callpoint to be notified in the event of Callpoint activation The database must be populated manually To add an entry to the database enter the IP Address a descri...

Page 28: ...d as an IP address and Layer 4 Port and can in either tcp or udp format The packet payload can contain any data although short cuts exist for commands to Netgenium devices Add An Event Navigate to Uti...

Page 29: ...t and click the EDIT button Enter the data the event packet is to contain The data can be typed into the textbox as shown The example illustrated shows an event in XML format Shortcuts to Netgenium co...

Page 30: ...atures the ability to test each function of the controller remotely and the ability to upgrade the firmware of the controller Status Provides the following data Lock Status Show the current status of...

Page 31: ...iary Status Shows the current status of any Auxiliary Inputs connected to Flex I O Fire Status Shows the current status of any fire alarm inputs connected to Flex I O CallPoint Status Shows the curren...

Page 32: ...able Lock Test Simulate the Timed and Toggle operation of the lock port Click the appropriate button to use this feature RTX Simulates the Request To Exit button being pressed if configured Callpoint...

Page 33: ...es This buffer is stored in volatile memory and is lost when the unit is powered off To clear the buffer manually click the Clear Logs button Default Navigate to Maintenance Default Clicking the DEFAU...

Page 34: ...be updated via a TFTP server To update the firmware 1 A TFTP server must be available on the network 3 The ALK370x image should be stored in the TFTP root directory 4 Tick the Enable TFTP Upload chec...

Page 35: ...iagnostics 34 The upload process will begin The current status of the upload process is displayed in the Live Status window The correct upload Uploading File Writing Main Image Writing Header Rebootin...

Page 36: ......

Reviews: