To install the RPS4000v2:
1. Attach the supplied mounting brackets to the side of the RPS4000v2.
2. Use the provided Phillips head screws to fasten the brackets to the sides of
the RPS4000v2.
3. Tighten the screws with a No. 1 Phillips screwdriver to secure each bracket.
4. Align the bracket and rack holes. Use two pan-head screws with nylon
washers to fasten each bracket to the rack.
5. Tighten the screws with a No. 2 Phillips screwdriver to secure the switch in
the rack.
Check the installation
Before you apply power, perform the following checks:
1. Inspect the equipment thoroughly.
2. Verify that all cables are installed correctly.
3. Check cable routing to ensure that cables are not damaged and do not
create a safety hazard.
4. Be sure that all equipment is mounted properly and securely.
Connect a switch to the RPS4000v2
WARNING:
To prevent an electrical hazard, make sure that the RPS AC power
cord is not connected to the RPS before you install an APS1000W PSU or connect
the RPS to a switch.
1. Make sure an APS1000W PSU is installed into the power module bay on the
RPS4000v2.
2. Connect a switch to the corresponding RPS port.
3.
Based on the RPS specification for the switch, set the position for the Type
and CS selectors on the back panel of the RPS4000v2. See the
RPS4000v2
Hardware Installation Guide
for configuration instructions.
4. Connect the switch to the RPS port on the RPS4000v2 using a NETGEAR RPS
cable (60 cm, 16 pin).
5. Power on the APS1000W that is connected to the switch.
Specifications
Technical Specifications
RPS port interface
4 NTGR RPS ports, 16 pin
Power
100–240 VAC, 50–60 Hz
Dimensions (H x W x D)
1.7 x 17.32 x 16.92 in. (43 x 440 x 430 mm)
Weight
12.8 lbs (5.8 kg)
Operating temperature
0° to 50°C (32° to 104°F)
Operating humidity
90% maximum relative humidity, noncondensing
Safety agency
approvals
UL, LVD, CB
Support and Community
Visit
to get your questions answered and access the latest
downloads.
You can also check out our NETGEAR Community for helpful advice at
Regulatory and Legal
Si ce produit est vendu au Canada, vous pouvez accéder à ce document en
français canadien à
https://www.netgear.com/support/download/
.
(If this product is sold in Canada, you can access this document in Canadian
French at
https://www.netgear.com/support/download/
.)
For regulatory compliance information including the EU Declaration of
Conformity, visit
https://www.netgear.com/about/regulatory/
.
See the regulatory compliance document before connecting the power supply.
For NETGEAR’s Privacy Policy, visit
https://www.netgear.com/about/privacy-policy
.
By using this device, you are agreeing to NETGEAR’s Terms and Conditions at
https://www.netgear.com/about/terms-and-conditions
. If you do not agree, return
the device to your place of purchase within your return period.