background image

Installation Guide

3.  Connect devices to the switch. 

We recommend using the following cables and SFP modules: 
•  Use a Category 5e (Cat 5e), Category 6 (Cat 6), or Category 6a (Cat 6a) 

cable a for copper port at 1/2.5/5 Gbps.

• 

Use a NETGEAR AGM731F or AGM732F for a fiber port at 1 Gbps.

• 

Use a NETGEAR AXM761, AXM762, or AXM764 for a fiber port at 10 Gpbs.

• 

Use a NETGEAR AXC761 (1 m) or AXC763 (3 m) cable for a fiber port.

Note: 

If purchased, SFP modules and cables are shipped separately. For more 

information about installing an SFP module, see the hardware installation guide.

2. Configure the IP address of the switch

You can access the switch through the out-of-band (OOB) port (which is also 
referred to as the service port) through a console port, or through any Ethernet 
network port. By default, the switch functions as a DHCP client.

To configure the IP address of the switch, use 

one

 of the following methods:

• 

Local browser–based management interface

. Use the local browser interface 

through the OOB port or any Ethernet network port (see 

Use the local browser 

interface to configure the IP address

).

• 

CLI

. Use the command-line interface (CLI) through the mini USB console port 

or RJ-45 RS232 console port. You can configure the IP address manually or use 
the ezconfig utility (see 

Use the CLI to configure the IP address

).

• 

DHCP server

. Connect a DHCP server through the OOB port or through 

any Ethernet network port and find the assigned IP address (see 

Find the IP 

address assigned by the DHCP server

).

After you configure or find the IP address of the switch, you can configure the 

features of the switch through either the local browser interface or the CLI.

Use the local browser interface to configure the IP address

Y

ou can use a computer on the same subnet as the switch to access the local 

browser interface over the switch’s default IP address and assign a different static 
IP address to the switch.

1. 

Configure your computer with a static IP address:

•  For access over an Ethernet network port, use an IP address in the 

NETGEAR ProSAFE Managed Switches

M4200 Series

1. Set up the switch

Prepare the installation site so that mounting, access, power source, and 
environmental requirements are met. For more information about these 
requirements, visit 

www.netgear.com/support

.

To set up the switch:

1.  Install the switch using one of the following methods:

• 

Placed on a flat surface

•  Attached to a wall
•  Attached to a rectangular or round pole or table leg
•  Installed in a rack
Follow the installation instructions in the hardware installation guide.

2.  Apply AC power.

The Power LED lights solid yellow while the switch conducts a power-on self-
test (POST). After the switch passes the POST, the Power LED lights solid green, 
and the switch is functional. If the Power LED does not light green, see the 
following troubleshooting tips:
•  If the POST fails, the Power LED remains solid yellow. See the 

troubleshooting section of the hardware installation guide for more 
information.

•  If the Power LED does not light at all, check to see that the power cable is 

plugged in correctly and that the power source is functioning. If this action 
does not resolve the problem, see the troubleshooting section of the 
hardware installation guide for more information.

169.254.0.0/16 subnet. For example, use 169.254.100.201.

• 

For access over the OOB port, use an IP address in the 192.168.0.0/16 
subnet. For example, use 192.168.0.100.

2.  Connect an Ethernet cable from an Ethernet port on your computer to an 

Ethernet network port on the switch or to the OOB port on the switch.

3.  Launch a web browser and enter the default IP address of the switch in the 

address field of the browser:

•  For access over an Ethernet network port, enter 

169.254.100.100

.

•  For access over the OOB port, enter 

192.168.0.239

.

A login window displays.

4.  Enter 

admin

 for the user name, leave the password field blank, and click the 

LOGIN

 button. 

The System Information page displays.

5.  Select 

System > Management > Initial Setup

.

6. 

Configure the IP address settings of the management interface and OOB port.

7.  Click the 

Apply

 button.

Your setting are saved.

For information about using the local browser interface, see the user manual, 
which you can download by visiting 

netgear.com/support/download/

.

Use the CLI to configure the IP address

To use the CLI for initial configuration and assign a static or dynamic IP address 
to the switch, connect a computer or VT100/ANSI terminal to one of the console 

ports on the switch.

1.  Depending on the connector type at your computer or terminal, and the port 

that you are using on the switch, use one of the following cables, both of which 
are included in the product package:
•  USB console cable for use with the mini USB console port.

Note: 

To use the mini USB port, you must install the USB driver on the 

computer. You can download the driver by visiting 

netgear.com/support/download/

.

•  Console cable for use with the RJ-45 RS232 console port.