Technical Specifications

A-3

v1.0, March 2006

Environment

• Operating temperature: 32° to 122°F (0° to 50°C) 
• Storage temperature: – 4° to 158°F (–20° to 70°C)
• Operating humidity: 90% maximum relative humidity, noncondensing 
• Storage humidity: 95% maximum relative humidity, noncondensing 
• Operating altitude: 10,000 ft (3,000 m) maximum 
• Storage altitude: 10,000 ft (3,000 m) maximum 

Electromagnetic 
emissions and immunity

• CE mark, commercial 
• FCC Part 15 Class A VCCI 
• Class A EN 55022 (CISPR 22)
• Class A C-Tick 
• EN 50082-1 

 

EN 55024 

Safety 

• CE mark, commercial 
• CSA certified (CSA 22.2 #950)
• UL listed (UL 1950)/cUL IEC950/EN60950 

Table A-1. Technical Specifications

Feature

GSM7328S

GSM7352S

Summary of Contents for GSM7328FS - ProSafe Switch - Stackable

Page 1: ...201 10813 01 March 2006 NETGEAR Inc 4500 Great America Parkway Santa Clara CA 95054 USA Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide...

Page 2: ...with the conditions set out in the BMPT AmtsblVfg 243 1991 and Vfg 46 1992 The operation of some equipment for example test transmitters in accordance with the regulations may however be subject to ce...

Page 3: ...e du minist re des Communications du Canada Cet appareil num rique NETGEAR ProSafe 48 Port 10 100 1000 L3 managed Stackable Switch with 4 High speed Module Bays GSM7352S respecte les limites de bruits...

Page 4: ...wser such as Internet Explorer or Netscape are required Product and Publication Details Warning This is a Class A product In a domestic environment this product may cause radio interference in which c...

Page 5: ...ructions 2 7 Chapter 3 Hardware Installation Package Contents 3 1 Protecting Against Electrostatic Discharge 3 2 Unpacking the Hardware 3 2 Installation 3 3 Select a Location 3 4 Install the Switch 3...

Page 6: ...ion Version 1 0 March 2006 ii Chapter 4 Troubleshooting Troubleshooting Chart 4 1 Additional Troubleshooting Suggestions 4 2 Appendix A Technical Specifications A1 Appendix B Default Configuration Set...

Page 7: ...concepts and terminology This guide uses the following typographical conventions This guide uses the following formats to highlight special messages Table 1 1 Typographical Conventions Italics Emphas...

Page 8: ...Danger This is a safety warning Failure to take heed of this notice may result in personal injury or death Table 1 2 Manual Scope Product Version ProSafe 24 Port 10 100 L3 managed Stackable Switch wit...

Page 9: ...TGEAR switches ProSafe 48 Port 10 100 1000 L3 managed Stackable Switch with 4 High speed Module Bays GSM7352S ProSafe 48 Port 10 100 1000 L3 managed Stackable Switch with 4 High speed Module Bays GSM7...

Page 10: ...witches Off Switch acts as a slave unit in a stack of GSM7300S switches RPS redundant power supply Solid green The redundant power supply is connected and using internal power Solid yellow The switch...

Page 11: ...orts 2 LEDs per port Link ACT LED Off No link is established on the port Solid green A valid link is established on the port Blinking green The port is sending or receiving packets SPD LED Off No link...

Page 12: ...module bays support any combination of either the ProSafe 10 Gigabit Ethernet XFP Adapter AX741 or the ProSafe 24 Gigabit Stackable Module AX742 GSM7352S Front Panel and LEDs The figure below shows t...

Page 13: ...roviding power to the switch Blinking yellow The redundant power supply unit is present but the power has failed Off The redundant power supply is disconnected or not present Fan Red Fan has failed Of...

Page 14: ...LED XFP Module present LED ACT Off The 10GbE Adapter is not present Solid green The 10GbE Adapter is present Blinking green Packets transmission or reception is occurring on the port Stacking Adapter...

Page 15: ...provider The power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not ope...

Page 16: ...arked on the product To help prevent electric shock plug the system and peripheral power cables into properly grounded electrical outlets The peripheral power cables are equipped with three prong plug...

Page 17: ...dapter cord Rubber footpads for tabletop installation Rubber caps for the SFP sockets Rack mounting kit Null modem serial cable RS 232 with 9 pin connectors NETGEAR CD The CD contains Configuration so...

Page 18: ...nts in a static safe area If possible use antistatic floor pads workbench pads and an antistatic grounding strap Unpacking the Hardware Check the contents of the boxes to make sure that all items are...

Page 19: ...age immediately Installation Install the equipment in the sequence presented in this chapter as shown below 1 Select a Location See Select a Location on page 3 4 2 Install the Switch See Install the S...

Page 20: ...r source within 6 feet 1 8 meters of the installation location Power specifications for the switch are shown in Appendix A Technical Specifications Be sure that the AC outlet is not controlled by a wa...

Page 21: ...r footpad on each of the four concave spaces on the bottom of the switch The rubber footpads cushion the switch against shock and vibrations Installing the Switch in a Rack To install the switch in a...

Page 22: ...switch The only way to apply or remove power is to connect or disconnect the power cord Before you connect the power cord select an AC outlet that is not controlled by a wall switch which can turn off...

Page 23: ...hernet XFP Adapters AX741 The modules and adapters are sold separately SPF Modules The module bay accommodates a standard SFP module with an LC connector that is compatible with the IEEE 802 3z 1000BA...

Page 24: ...tallation The High Speed I O Module Bays support ProSafe 10 Gigabit Ethernet XFP Adapter AX741 or ProSafe 24 Gigabit Stackable Modules AX742 When the ProSafe 10 Gigabit Ethernet XFP Adapter AX741 is i...

Page 25: ...or the rear of each switch 2 Connect the provided stacking cable between a pair of AX742 modules in each switch within a stack 3 Connect each switch to the next in a cascade to build the backplane of...

Page 26: ...e switch When the power is off you can remove the cover plate and connect the RPS unit to the switch After all connections are completed apply power to the switch Connecting Equipment to the Switch Yo...

Page 27: ...or UNIX workstation Null modem cable with 9 pin connectors on each end shipped with the product To connect a console to the switch 1 Connect the null modem cable to the console port on the rear of th...

Page 28: ...his purpose Quick Install Guide Explains basic setup and configuration provided as both a print document and in PDF format on the NETGEAR CD Command Line Interface Reference for the ProSafe 7300S Seri...

Page 29: ...connection is not working Check the crimp on the connectors and make sure that the plug is properly inserted and locked into the port at both the switch and the connecting device Make sure that all c...

Page 30: ...installation do not exceed the Ethernet limitations Switch Integrity You can verify the integrity of the switch by resetting the switch To reset the switch use the Tools Reset command or remove AC po...

Page 31: ...tiate the correct duplex mode and speed if the device at the other end of the link supports auto negotiation If the device does not support auto negotiation the switch only determines the speed correc...

Page 32: ...Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide 4 4 Troubleshooting v1 0 March 2006...

Page 33: ...ASE SR 802 3x flow control Switch management Port mirroring support SNMP v1 v2c v3 RFC1757 RMON 1 groups 1 2 3 and 9 RFC1213 MIB II RFC1643 Ethernet Interface MIB RFC1493 bridge MIB RFC2131 DHCP clien...

Page 34: ...tors for 10BASE T 100BASE TX and 1000BASE T Eight slots are gigabit interface converters SFP for SFP modules Four I O module bays for either 10 Gigabit Ethernet or 24 Gigabit stacking connectivity RS...

Page 35: ...humidity noncondensing Storage humidity 95 maximum relative humidity noncondensing Operating altitude 10 000 ft 3 000 m maximum Storage altitude 10 000 ft 3 000 m maximum Electromagnetic emissions an...

Page 36: ...Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide A 4 Technical Specifications v1 0 March 2006...

Page 37: ...ed Flow control full duplex Disabled Broadcast storm control Enabled Gigabit port type Auto detect Management IP configuration DHCP Password protection Disabled User name Admin Password none Web acces...

Page 38: ...arch 2006 IP routing Disabled RIP Disabled MAC address aging 300 seconds OSPF Disabled SNMP community public read only access private read write access DHCP Server Disabled VLAN Ingress filtering Enab...

Page 39: ......

Page 40: ...NETGEAR Inc 4500 Great America Parkway Santa Clara CA 95054 USA March 2006...

Reviews: