Step 9: Apply AC power and check the LEDs

The switch does not provide an on/off switch. The power cord connection controls the
power. Before connecting the power cord, select an AC outlet that is not controlled by
a wall switch, which can turn off power to the switch.

To apply AC power and check the LEDs:

1. Connect the end of the power cord to the power receptacle on the power supply

unit (PSU) on back of the switch.
If you installed two PSUs, do this for both PSUs.

2. Check to see that the system LEDs on the front panel function as expected.

For more information about the LEDs, see the following sections:

LEDs, M4300 series full 10G models on page 21

LEDs, M4300 series 1G models with 10G uplinks on page 29

LEDs, M4300X series full 10G models with RJ45/SFP+ combo ports on page 38

When you apply power, the Power LED on the switch front panel lights. If the Power
LED does not light, check that the power cord is plugged in correctly and that the
power source is good.

If you installed two PSUs, the Power 1 LED on the front panel is associated with the
PSU 1 bay and the Power 2 LED is associated with the PSU 2 bay. If a Power LED
does not light, check to see that the power cord is plugged in correctly and that the
power source is good.

Hardware Installation Guide

61

Installation

M4300 Intelligent Edge Series Fully Managed Stackable Switches

Summary of Contents for 8X8F

Page 1: ...Hardware Installation Guide M4300 Intelligent Edge Series Fully Managed Stackable Switches NETGEAR Inc 350 E Plumeria Drive January 2020 San Jose CA 95134 USA 202 12073 01...

Page 2: ...202 12073 01 For all models changed the Fan LED behavior for a faulty fan condition from blinking yellow to solid yellow Made minor corrections to existing sections November 2019 202 11995 02 Added s...

Page 3: ...te Publication Part Number Added information to the Safety Instructions and Warnings section December 2015 202 11606 02 First publication December 2015 202 11606 01 3 M4300 Intelligent Edge Series Ful...

Page 4: ...10G uplinks 27 LEDs M4300 series 1G models with 10G uplinks 29 Hardware descriptions M4300 series full 10G models with RJ45 SFP combo ports 31 Front panel M4300 series full 10G models with RJ45 SFP co...

Page 5: ...an SFP transceiver module in a full 10G model 56 Install an SFP transceiver module in an uplink or combo port 57 Optional Step 6 Install a power supply unit 58 Optional Step 7 Connect a redundant pow...

Page 6: ...GEAR provides a separate hardware installation guide for modular model M4300 96X This hardware installation guide complements the installation guide that came with your switch This chapter serves as a...

Page 7: ...Switch model with twenty four 1G copper ports two 10G copper ports and two 10G fiber ports in a full width chassis M4300 28G POE Switch model with twenty four 1G PoE copper ports two 10G copper ports...

Page 8: ...r 10 and 100 Mbps speeds the ports can operate in half duplex or full duplex mode For 1G and 10G speeds the ports always operate in full duplex mode For certain models some limitations exist for half...

Page 9: ...dundancy Support for stacking on any 10G port Half width or full width model Full compatibility with IEEE standards IEEE 802 3i 10BASE T IEEE 802 3u 100BASE TX IEEE 802 3ab 1000BASE T IEEE 802 3an 10G...

Page 10: ...in a stack are stack members Slaves can download firmware from the master and the master can push firmware to the slaves The master runs the fully operational software of a switch In addition the mas...

Page 11: ...up to eight switches All models support stacking The master supports Nonstop Forwarding Failover NSF For information about how to configure stacking through the software see the software administrati...

Page 12: ...s and never operate the product in a wet environment If the system gets wet see the appropriate section in your troubleshooting guide or contact your trained service provider Do not push any objects i...

Page 13: ...f applicable to your device the peripheral power cables are equipped with three prong plugs to help ensure proper grounding Do not use adapter plugs or remove the grounding prong from a cable If you m...

Page 14: ...cludes the following sections Hardware descriptions M4300 series full 10G models Hardware descriptions M4300 series 1G models with 10G uplinks Hardware descriptions M4300 series full 10G models with R...

Page 15: ...M4300 series full 10G models The full 10G models provide either a port configuration of sixteen independent 10GBASE T autosensing ports or a port configuration of eight twelve or twenty four independe...

Page 16: ...rates the front panel of half width model M4300 8X8F Figure 2 Front panel model M4300 8X8F Description Number Power and Fan LEDs 1 Stack ID LED 2 USB port 3 RJ 45 RS232 console port 4 Stack Master LED...

Page 17: ...port 3 Stack Master LED 4 Reset button 5 Mini USB console port 6 10GBASE X SFP ports each with a port LED 7 10GBASE T ports each with a port LED 8 Model M4300 24X24F The following figure illustrates t...

Page 18: ...port models M4300 16X M4300 8X8F and M4300 24X24F On model M4300 12X12F the RJ 45 RS232 console port is on the back panel One out of band OOB 1G Ethernet port models M4300 16X M4300 8X8F and M4300 24...

Page 19: ...M4300 16X provides the following components Fixed fans for front to back air flow Modular bay in which either an APS299W or APS600W power supply unit PSU is installed Model M4300 8X8F The following f...

Page 20: ...t 1 OOB port with port LEDs 2 PSU with AC connector 3 From left to right the back panel of model M4300 12X12F provides the following components One out of band 1G Ethernet port One RJ 45 RS232 115200...

Page 21: ...ower 2 LED Power LED Off Sufficient more than 7W of PoE power is available Solid yellow Less than 7W of PoE power is available Blinking yellow At least once during the previous two minutes less than 7...

Page 22: ...00 Mbps link Blinking yellow The copper port is transmitting or receiving packets at 1 Gbps or 100 Mbps Non PoE models 10GBASE T RJ45 port LED one LED per port PoE model M4300 16X right side PoE statu...

Page 23: ...copper PoE ports two 10G copper ports and two 10G fiber ports Front panel M4300 series 1G models with 10G uplinks The 1G models with 10G uplinks provide twenty four or forty eight 1000BASE T autosens...

Page 24: ...nt panel of full width model M4300 28G POE Figure 10 Front panel model M4300 28G POE Description Number Power 1 Power 2 and Fan LEDs 1 Stack ID LED 2 10GBASE T ports each with a port LED 3 OOB port wi...

Page 25: ...tack Master LED 5 Reset button 6 Mini USB console port 7 1000BASE T ports each with a port LED 8 10GBASE X SFP ports each with a port LED 9 USB port 10 Model M4300 52G POE Model M4300 52G POE supports...

Page 26: ...000BASE T RJ 45 ports each with a left LED and a right LED see LEDs M4300 series 1G models with 10G uplinks on page 29 The LED functionality depends on the model Non PoE models On model M4300 28G and...

Page 27: ...re illustrates the back panel of full width models M4300 28G M4300 28G POE and M4300 52G Figure 13 Back panel models M4300 28G M4300 28G POE and M4300 52G Description Number RJ 45 RS232 console port 1...

Page 28: ...he back panel of model M4300 52G POE provides the following components One RJ 45 RS232 115200 N 8 1 console port One redundant power supply RPS interface Fixed fans for front to back air flow Modular...

Page 29: ...unctioning normally Blinking yellow One or more fans failed Off Power is not supplied to the switch Power 1 LED for PSU 1 and Power 2 LED for PSU 2 Solid green The fans are functioning normally Solid...

Page 30: ...copper port Solid green The copper port established a 10 Gbps link Blinking green The copper port is transmitting or receiving packets at 10 Gbps Solid yellow The copper port established a 1 Gbps or 1...

Page 31: ...fiber SFP ports and two 10G RJ45 SFP combo ports in a full width chassis Front panel M4300 series full 10G models with RJ45 SFP combo ports The full 10G models with RJ45 SFP combo ports provide eithe...

Page 32: ...ustrates the front panel of half width model M4300 24XF Figure 16 Front panel model M4300 24XF Figure Number Power and Fan LEDs 1 Stack ID LED 2 USB port 3 Stack Master LED 4 Reset button 5 Mini USB c...

Page 33: ...5 Mini USB console port 6 10GBASE T ports each with a port LED 7 Combo ports each with a port LED 8 Ports 45T 46T 47T and 48T are 10GBASE T ports Ports 45F 46F 47F and 48F 10GBASE X SFP ports Model M...

Page 34: ...ge 38 Because models M4300 48X and M4300 48XF can support two PSUs the front panel provides both a Power 1 LED and Power 2 LED Recessed Reset button One mini USB console port One USB 2 0 port Dependin...

Page 35: ...panel 3 PSU with AC connector 4 From left to right the back panel of model M4300 24X provides the following components Fixed fan for front to back air flow One RJ 45 RS232 115200 N 8 1 console port On...

Page 36: ...to right the back panel of model M4300 24XF provides the following components Fixed fan for front to back air flow One RJ 45 RS232 115200 N 8 1 console port One out of band OOB 1G Ethernet port with...

Page 37: ...lowing components Modular bay for power supply unit 1 PSU 1 which is an APS250W Fixed fans for front to back air flow One RJ 45 RS232 115200 N 8 1 console port One out of band OOB 1G Ethernet port wit...

Page 38: ...G Ethernet port with a left LED that indicates the speed and a right LED that indicates the activity see LEDs M4300X series full 10G models with RJ45 SFP combo ports on page 38 Modular bay PSU 2 for a...

Page 39: ...ished on the port Solid green The port established a 1000 Mbps link Solid yellow The port established a 10 or 100 Mbps link OOB Ethernet port LEDs two LEDs per port Right side activity and link LED Of...

Page 40: ...cluding 10GBASE T RJ 45 ports All copper RJ 45 ports support autosensing When you insert a cable into an RJ 45 port the switch automatically ascertains the maximum speed 10 Mbps 100 Mbps 1 Gbps or 10...

Page 41: ...to 16 only Model M4300 52G supports half duplex mode on ports 1 to 16 and ports 25 to 40 only M4300 52G POE supports half duplex mode on ports 1 to 16 and ports 25 to 40 only 10GBASE X 1000BASE X and...

Page 42: ...sories If purchased transceiver modules and cables are shipped separately form the switch USB port The switch provides one USB 2 0 port that lets you upgrade firmware from a disk back up the configura...

Page 43: ...box and click the Downloads button on the product page RJ 45 RS232 console port The switch provides one RJ 45 RS232 console port for console access only This serial port is configured for 115200 baud...

Page 44: ...4300 16X 1x APS250W M4300 8X8F 1x APS250W M4300 12X12F 1x APS250W 2x APS250W M4300 24X24F 1x APS150W 2x APS150W M4300 28G 1x APS150W 2x APS150W M4300 52G N 1 redundancy is supported for this model 1x...

Page 45: ...POE differ and depend on the installed PSU or PSUs The following tables describe the PoE power budgets Table 6 PSU and PoE budgets for model M4300 16X M4300 16X PoE Power Budget PSU Configuration PSU...

Page 46: ...E Power Budget PSU Configuration PSU Single or dual PSU 591W 630W 1 1 RPS mode 110 VAC input Dual APS1000W 860W 720W 1 1 RPS mode 220 VAC input 1 010W 720W EPS mode 110 VAC input 1 440W 720W EPS mode...

Page 47: ...ep 2 Protect against electrostatic discharge Step 3 Unpack the switch Step 4 Install the switch Optional Step 5 Install SFP transceiver modules Optional Step 6 Install a power supply unit Optional Ste...

Page 48: ...erature Install the switch in a dry area with an ambient temperature between 0 C and 50 C 32 F and 122 F Keep the switch away from heat sources such as direct sunlight warm air exhausts hot air vents...

Page 49: ...safe area If possible use antistatic floor pads workbench pads and an antistatic grounding strap Step 3 Unpack the switch The following figure shows half width model M4300 12X12F The package contents...

Page 50: ...al 4 Verify that the package contains the following items Switch of the correct model Power cord Console cable with one DB9 connector and one RJ 45 connector USB console cable with one mini B connecto...

Page 51: ...full width switch in a rack To install the switch in a rack you need the 19 inch rack mount kit supplied with the switch To install a full width switch in a rack 1 Attach the supplied mounting bracke...

Page 52: ...k To install a single half width switch in single rack space you need the 19 inch rack mount kit supplied with the switch The figures in the following procedure shows model M4300 24X However you insta...

Page 53: ...e rack mount kit through each bracket and into the bracket mounting holes in the switch 3 Tighten the screws with a No 1 Phillips screwdriver to secure each bracket 4 Align the mounting holes in the b...

Page 54: ...in the rack mount kit through the mounts and into the mounting holes in the switch Position the male mounts on the same side of the switch and the female mounts of the switch on the other side b Tigh...

Page 55: ...ight switch 4 Insert the screws provided in the rack mount kit through the holes in each middle mount 5 Tighten the screws with a No 1 Phillips screwdriver to secure each middle mount Hardware Install...

Page 56: ...ainst shock and vibrations They also provide ventilation space between stacked switches To install the switch on a flat surface Stick one rubber footpad on each of the four concave spaces on the botto...

Page 57: ...ransceiver module in a 1G model with 10G uplinks or a 10G model with RJ45 SFP combo ports That is this procedure is for models M4300 24X M4300 24XF M4300 28G M4300 28G POE M4300 48X M4300 48FX M4300 5...

Page 58: ...ou can install an optional second PSU M4300 24X24F M4300 48X and M4300 48XF M4300 28G and M4300 28G POE M4300 52G and M4300 52G POE For these models the PSU that is shipped with the product is install...

Page 59: ...ug the AC power cord into a power source such as a wall socket or power strip When you install a second PSU and apply power the Power 2 LED on the switch front panel lights If the Power 2 LED does not...

Page 60: ...cord of the RPS into a power source such as a wall socket or power strip 6 Power on the switch Step 8 Check the installation Before you apply power to the switch perform the steps that are described...

Page 61: ...LEDs see the following sections LEDs M4300 series full 10G models on page 21 LEDs M4300 series 1G models with 10G uplinks on page 29 LEDs M4300X series full 10G models with RJ45 SFP combo ports on pa...

Page 62: ...ort is located on the front panel On the half width models M4300 16X M4300 8X8F M4300 12X12F M4300 24X and M4300 24XF the RJ 45 RS232 console port is located on the front panel On the full width model...

Page 63: ...l which you can download by visiting netgear com support download For information about configuring the switch through its local browser interface see the software administration guide and the user ma...

Page 64: ...r provides information about maintaining and troubleshooting the switch The chapter includes the following sections Replace a power supply unit Replace a half width switch in a rack Troubleshooting ch...

Page 65: ...If your switch functions with a single PSU only disconnect the power cord from the PSU and let the switch power down If your switch functions with two PSUs you do not need to power down the switch and...

Page 66: ...od Replace a half width switch in a rack This step describes how to replace a half width switch that is mounted next to a second half width switch on a rack You can skip this procedure if the middle m...

Page 67: ...mounts by inserting the screws provided in the rack mount kit with a No 1 Philips screwdriver 7 Gently push the new half width switch into the rack until the holes in each middle mount are aligned 8 A...

Page 68: ...at a broadcast storm occurred and that a network loop redundant path was created A file transfer is slow or the performance is degraded Verify that the cabling is correct Make sure that all connectors...

Page 69: ...ch integrity If necessary verify the integrity of the switch by resetting it To reset the switch disconnect the AC power from the switch and then reconnect the AC power If the problem continues contac...

Reviews: