MAN-REF-CASW Web
Browser
Interface
Page
15
CON Director, a port number of 1 should be specified if connection is
to an IBM or Hitachi IBM-compatible system; a port number of 2
should be specified if connection is to a Unisys system.
LPAR -
the partition number of the host driving this interface if the channel is
defined as SHARED. If the system is running in BASIC mode, or if
the system is running in LPAR mode but the channels are defined as ei-
ther RECONFIGURABLE or DEDICATED, then the value specified
for LPAR must be zero.
⇒
Caution: It is extremely important that the values specified for UADD, CU, Chlink, and
LPAR exactly match the values specified in the host system's device configuration. Failure to
do so will make the devices unusable.
The total number of devices supported on each ESCON interface board is 64. Use this selection button
multiple times until all required device interfaces are defined.
Channel Set Debug
This button sets the debug trace level for all interfaces, or for a specific channel interface. Prior to se-
lecting this button, provide the following data on the selection screen:
IFname
the name of the channel interface for which to enable debug.
VALUE:
0 : no console tracing
1 : console trace only H level messages
2 : console trace level H and M messages
3 : console trace level H, M, and L messages
4 : console trace level H, M, L, and D messages
5 : console trace the actual streams messages
6 : console trace the message data
7 : console trace all the data
global
set Channel debug level globally