background image

 

 

3

General Information  

 

Trademarks 

MicroSim is the trademark of Netech Corporation. Any other trademark 
names used in this manual are only for editorial purposes and the benefit 
of the respective trademark owner with no intention of improperly using 
that trademark.

 

 

Copyright 

 

Copyright © 2007 by Netech Corporation. All rights reserved. No part of 
this publication may be reproduced or transmitted in any form other than 
for the purchaser’s personal use without written permission from Netech 
Corporation.

 

 

Quality Assurance

 

 

Netech is ISO 9001-2000 Certified. This instrument was thoroughly tested 
and inspected according to Netech’s ISO 9001-2000 quality standards 
and test procedures and found to meet those specifications when it was 
shipped from the factory. 

 

Refunds and Credits 

 

Please note that only serialized products and their accessory items (i.e., 
products and items bearing a distinct serial number tag) are eligible for 
partial refund and/or credit. Non-serialized parts and accessory items 
(e.g., cables, carrying cases, auxiliary modules, etc.) are not eligible for 
return or refund. Only products returned within 90 days from the date of 
original purchase are eligible for refund/credit.

 

 

 

In order to receive a partial refund/credit of a product purchase price on a 
serialized product, the product must not have been damaged by the customer 
or by the carrier chosen by the customer to return the goods, and the product 
must be returned complete (meaning with all manuals, cables, accessories, 
etc.) and in “as new” and resalable condition.

  

 

Products not returned within 90 days of purchase, or products, which are not in 
“as new”, and resalable condition, are not eligible for credit return and will be 
returned to the customer. The Return Procedure (see below) must be followed 
to assure prompt refund / credit. 

 

Restocking Charges 

 

Products returned within 30 days of original purchase are subject to a 
minimum restocking fee of 15 %, in excess of 30 days, 20 %. Additional 
charges for damage and / or missing parts and accessories will be applied to 
all returns.

Summary of Contents for MicroSim COS

Page 1: ...COS Cardiac Output Simulator The one and only that simulates a true waveform Operating Manual Netech Corporation 110 Toledo Street Farmingdale NY 11735 Phone 631 531 0100 Fax 631 531 0101 http www Ne...

Page 2: ...ue the MICROSIM COS at any time and change its specifications price or design without notice and without incurring any obligation Netech guarantees violability of service parts for 5 years after the m...

Page 3: ...ble for partial refund and or credit Non serialized parts and accessory items e g cables carrying cases auxiliary modules etc are not eligible for return or refund Only products returned within 90 day...

Page 4: ...er service dept before a product is returned for refund or credit The RMA number should be clearly marked on the package along with the a statement indicating the reason for return Repair and Calibrat...

Page 5: ...d Line Conducted Emissions Verification of compliance was conducted to the limits and methods of the following CISPR 16 1 1993 and CISPR 16 2 1996 Immunity The system has been type tested and found to...

Page 6: ...EEC Low Voltage The system has been type tested and found to meet the requirements of EC Directive 73 23 EEC for Low Voltage Verification of compliance was conducted to the limits and methods of the...

Page 7: ...Interface 5 EC Directive 6 Table of Contents 7 1 General Overview 1 1 Introduction 8 1 2 Specifications 8 1 3 Accessories 2 Operating Instructions 2 1 Getting Started 9 2 2 Instrument Familiarity 9 2...

Page 8: ...out put monitors It is compact lightweight and rugged The MICROSIM COS is operated via easy to use menus displayed on its LCD display It is battery operated 1 2 Specifications Catheter Size 7F Inject...

Page 9: ...e Netech warranty statement is listed in the warranty section of this manual When shipping an instrument to Netech for repair or calibration make sure that the instrument is properly packed A complete...

Page 10: ...elections The display consists of a 16x2 character LCD display The menu structure is as follows Initialization Menu On power up the initialization screen will appear N E T E C H C O S 2 0 0 0 Internal...

Page 11: ...e c t i o n C O I T B T C f g F1 F2 F3 F4 Active keys in the Selection Menu CO F1 Enters the CO rate selection menu IT F2 Enters the Injectate Temperature selection menu BT F3 Enters the Blood Temper...

Page 12: ...resistance of an ideal Catheter thermistor The two selections available are 37 C 98 6 F and 38 C 100 4 F The current setting is displayed Selecting a new value returns you to the Main Screen Press Es...

Page 13: ...essage will display This function is also performed on power up Notes on proper operation When a change in temperature selection is made either Blood Temp or Inj Temp the simulated resistance outputs...

Page 14: ...ired blood temperature injectate temperature and CO rate settings as outlined in section 2 3 5 Allow 10 seconds for the baseline to stabilize 6 Press the Start button on the monitor under test 7 Press...

Page 15: ...umper short This is a calibration procedure error It is meant as a reminder to disable calibration before leaving a calibration lab If this error should appear during normal operation an internal faul...

Page 16: ...16 Appendix Section 4...