Eject the module.
Slide out of chassis.
1. Locate the USB LED module on the front of the old chassis, directly under the power supply bays.
2. Press the black locking button on the right side of the module to release the module from the chassis, and
then slide it out of the old chassis.
3. Align the edges of the module with the USB LED bay at the bottom-front of the replacement chassis, and
gently push the module all the way into the chassis until it clicks into place.
Step 8: Install the de-stage controller power module when replacing the chassis
Once the replacement chassis is installed into the rack or system cabinet, you must reinstall the de-stage
controller power modules into it.
1. If you are not already grounded, properly ground yourself.
2. Align the end of the DCPM module with the chassis opening, and then gently slide it into the chassis until it
clicks into place.
The module and slot are keyed. Do not force the module into the opening. If the module
does not go in easily, realign the module and slide it into the chassis.
3. Repeat this step for the remaining DCPM module.
Step 9: Install fans into the chassis
To install the fan modules when replacing the chassis, you must perform a specific
sequence of tasks.
1. If you are not already grounded, properly ground yourself.
2. Align the edges of the replacement fan module with the opening in the chassis, and then slide it into the
chassis until it snaps into place.
When inserted into a live system, the amber Attention LED flashes four times when the fan module is
successfully inserted into the chassis.