E2600 Controller-Drive Tray Installation Guide
11
Things to Know – Taking a Quick Glance at the Hardware in a E2612
Controller-Drive Tray or a E2624 Controller-Drive Tray Configuration
WARNING
(W14)
Risk of bodily injury
– A qualified service person is required to make the DC power
connection according to NEC and CEC guidelines.
CAUTION
(C05)
Electrical grounding hazard
– This equipment is designed to permit the connection of the DC
supply circuit to the earthing conductor at the equipment.
NOTE
Each tray in the storage array must have a minimum of two drives for proper operation.
NOTE
iSCSI host ports do not support the Data Assurance (DA) premium feature.
ATTENTION Possible data loss
– If you remove all Fibre Channel Host Interface Cards (HICs) from a storage
array and replace them with HICs of a different network protocol (such as iSCSI or SAS), you must first deactivate
the Remote Volume Mirroring (RVM) premium feature if it is activated. If you do not deactivate RVM before
removing the Fibre Channel HICs, your system loses data access and data loss might occur.
The top of the controller-drive tray is the side with labels.
The configuration of the host ports might appear different on your system depending on which host interface
card configuration is installed.
Figure 5 E2612 Controller-Drive Tray – Front View
1.
End Cap Standby Power LED
2.
End Cap Power LED
3.
End Cap Over-Temperature LED
4.
End Cap Service Action Required LED
5.
End Cap Locate LED
6.
Drive Canister
Summary of Contents for E2600
Page 4: ...iv ...
Page 32: ...24 E2600 Controller Drive Tray Installation Guide ...
Page 36: ...28 E2600 Controller Drive Tray Installation Guide ...
Page 100: ...E2600 Controller Drive Tray Installation Guide 92 ...
Page 138: ...130 E2600 Controller Drive Tray Installation Guide ...
Page 141: ......
Page 142: ...Copyright 2012 NetApp Inc All rights reserved ...