NetApp AltaVault Cloud Integrated Storage Installation and Service Guide for Physical Appliances
9
Environmental site system requirements
NetApp AltaVault appliance setup preparation
Environmental site system requirements
The following table summarizes the environmental requirements for the normal operation of the AltaVault system:
Controller electrical requirements
The following table summarizes the electrical requirements for an AltaVault controller module in a single controller
per chassis configuration. It shows data for a single-controller configuration with one functioning power supply
(worst-case scenario) and the typical electrical requirements with two functioning power supplies:
Configuration worksheet
Use the configuration worksheet to note any information that you require for the AltaVault deployment, including:
“Appliance information” on page 39
“Cloud provider credentials and storage configuration” on page 39
“Network connectivity” on page 40
Environmental tolerances
Normal operating range
Operating temperature range
50 degrees F (10 degrees C) to 104degrees F (40degrees C)
Altitude
0 to 10,000 feet (0 to 3,048 m)
Relative humidity
20% to 80%, non-condensing
Specifications
Number of power supply
units (PSU)
100 to 120 VAC
200 to 240 VAC
Input current (Amps)
One PSU
Two PSU
4.55 A
3.86 A
2.49 A
2.33 A
Input Power (Watts)
One PSU
Two PSU
610.06 W
488.32
577.29 W
481.13 W
Thermal output (British
Thermal Unit per hour)
One PSU
Two PSU
2082 BTU/Hr
1666 BTU/Hr
1970 BTU/Hr
1642 BTU/Hr