background image

2. Halt the controller, pressing 

y

 when you are prompted to confirm the halt: 

system node halt -node

node_name

The confirmation message looks like the following:

Warning: This operation will cause controller "node-name" to be marked
as unhealthy. Unhealthy nodes do not participate in quorum voting. If
the controller goes out of service and one more controller goes out of
service there will be a data serving failure for the entire cluster.
This will cause a client disruption. Use "cluster show" to verify
cluster state. If possible bring other nodes online to improve the
resiliency of this cluster.

Do you want to continue? {y|n}:

You must perform a clean system shutdown before replacing the chassis to avoid losing
unwritten data in the nonvolatile memory (NVMEM/NVRAM). Depending on your system, if
the NVMEM/NVRAM LED is flashing, there is content in the NVMEM/NVRAM that has not
been saved to disk. You need to reboot the controller and start from the beginning of this
procedure. If repeated attempts to cleanly shut down the controller fail, be aware that you
might lose any data that was not saved to disk.

3. Where applicable, halt the second controller to avoid a possible quorum error message in an HA pair

configuration: 

system node halt -node 

second_node_name

 -ignore-quorum-warnings true

-skip-lif-migration-before-shutdown true

Answer 

y

 when prompted.

Option 2: Controllers are in a two-node MetroCluster configuration

To shut down the impaired controller, you must determine the status of the controller and, if necessary, switch
over the controller so that the healthy controller continues to serve data from the impaired controller storage.

About this task

• If you are using NetApp Storage Encryption, you must have reset the MSID using the instructions in the

"Return a FIPS drive or SED to unprotected mode" section of 

NetApp Encryption overview with the CLI

.

• You must leave the power supplies turned on at the end of this procedure to provide power to the healthy

controller.

Steps

1. Check the MetroCluster status to determine whether the impaired controller has automatically switched

over to the healthy controller: 

metrocluster show

2. Depending on whether an automatic switchover has occurred, proceed according to the following table:

If the impaired controller…

Then…

Has automatically switched over

Proceed to the next step.

2

Summary of Contents for AFF A300

Page 1: ...assis ONTAP Systems NetApp May 13 2022 This PDF was generated from https docs netapp com us en ontap systems a300 chassis replace overview html on May 13 2022 Always check docs netapp com for the late...

Page 2: ...Table of Contents Chassis 1 Overview of chassis replacement AFF A300 1 Shut down the controllers AFF A300 1 Replace hardware AFF A300 4 Restore and verify the configuration AFF A300 10...

Page 3: ...s Option 1 Shut down the controller You must shut down the controller or controller in the chassis prior to moving them to the new chassis About this task If you have a cluster with more than two cont...

Page 4: ...e any data that was not saved to disk 3 Where applicable halt the second controller to avoid a possible quorum error message in an HA pair configuration system node halt node second_node_name ignore q...

Page 5: ...egates is successful If the healing is vetoed you have the option of reissuing the metrocluster heal command with the override vetoes parameter If you use this optional parameter the system overrides...

Page 6: ...pplies fans and controller modules from the impaired chassis to the new chassis and swap out the impaired chassis from the equipment rack or system cabinet with the new chassis of the same model as th...

Page 7: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 5...

Page 8: ...all the way into the chassis and then push the cam handle to the closed position making sure that the cam handle release latch clicks into its locked position 8 Reconnect the power cable and secure i...

Page 9: ...epeat the preceding steps for any remaining fan modules 6 Insert the fan module into the replacement chassis by aligning it with the opening and then sliding it into the chassis 7 Push firmly on the f...

Page 10: ...he cables were connected Leave the cables in the cable management device so that when you reinstall the cable management device the cables are organized 3 Remove and set aside the cable management dev...

Page 11: ...the equipment rack or system cabinet using the screws you removed from the old chassis 7 If you have not already done so install the bezel Step 5 Install the controller After you install the controll...

Page 12: ...o the locked position Tighten the thumbscrew on the cam handle on back of the controller module Do not use excessive force when sliding the controller module into the chassis to avoid damaging the con...

Page 13: ...c mcc 2n mccip non ha b Confirm that the setting has changed ha config show 3 If you have not already done so recable the rest of your system 4 The next step depends on your system configuration If yo...

Page 14: ...mpts until the Maintenance mode prompt appears 4 Enable the interconnect diagnostics tests from the Maintenance mode prompt sldiag device modify dev interconnect sel enable The interconnect tests are...

Page 15: ...both controllers at the LOADER prompt bye e Return the controller to normal operation If your system is running ONTAP Then With two nodes in the cluster Issue these commands node cluster ha modify co...

Page 16: ...you can perform the MetroCluster switchback operation This returns the configuration to its normal operating state with the sync source storage virtual machines SVMs on the formerly impaired site now...

Page 17: ...switchback operation is complete when the clusters are in the normal state cluster_B metrocluster show Cluster Configuration State Mode Local cluster_B configured normal Remote cluster_A configured no...

Page 18: ...WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE NetApp reserves the...

Reviews: