8
D-Net 8550
TM
USER MANUAL
TECHNICAL DATA
Max. lateral length - 10% flow variation
Inlet pressure: 3.0 bar
S
lo
pe
Distance between sprinklers (m)
9
10
11
12
13
Max. lateral length (m)
Uphill
2%
126
130
143
144
156
1%
135
140
154
156
169
Flat terrain 0
153
160
165
180
195
Downhill
-1%
162
170
187
192
208
-2%
171
180
198
204
221
Nozzle size
2.3 + 1.8,
510 l/h*
Lateral: PE 40 mm
ID: 36.8 mm
Lateral: PE 50 mm
ID: 45.4 mm
S
lo
pe
Distance between sprinklers (m)
9
10
11
12
13
Max. lateral length (m)
Uphill
2%
117
120
132
132
143
1%
126
130
143
156
156
Flat terrain 0
135
150
154
168
182
Downhill
-1%
144
160
165
180
195
-2% 153
170
176
192
208
Nozzle size
2.5 + 1.8,
580 l/h*
S
lo
pe
Distance between sprinklers (m)
9
10
11
12
13
Max. lateral length (m)
Uphill
2%
108
110
121
132
130
1%
117
120
132
144
143
Flat terrain 0
126
130
143
156
156
Downhill
-1%
135
140
154
168
169
-2% 144
150
165
168
182
Nozzle size
2.9 + 1.8,
680 l/h*
S
lo
pe
Distance between sprinklers (m)
9
10
11
12
13
Max. lateral length (m)
Uphill
2%
99
100
110
120
117
1%
108
110
121
132
130
Flat terrain 0
117
120
132
132
143
Downhill
-1%
117
130
143
144
156
-2% 126
140
143
156
169
Nozzle size
3.2 + 1.8,
810 l/h*
S
lo
pe
Distance between sprinklers (m)
9
10
11
12
13
Max. lateral length (m)
Uphill
2%
90
100
99
108
117
1%
99
100
110
120
117
Flat terrain 0
99
110
121
120
130
Downhill
-1% 108
120
121
132
143
-2%
117
120
132
144
143
Nozzle size
3.5 + 1.8,
940 l/h*
S
lo
pe
Distance between sprinklers (m)
9
10
11
12
13
Max. lateral length (m)
Uphill
2%
81
90
99
96
104
1%
90
90
99
108
117
Flat terrain 0
90
100
110
108
117
Downhill
-1%
99
100
110
120
130
-2%
99
110
121
120
130
Nozzle size
3.5 + 2.5,
1135 l/h*
S
lo
pe
Distance between sprinklers (m)
9
10
11
12
13
Max. lateral length (m)
Uphill
2%
81
80
88
96
104
1%
81
90
99
96
104
Flat terrain 0
90
90
99
108
117
Downhill
-1%
90
100
99
108
117
-2%
90
100
110
120
117
Nozzle size
4.0 + 2.5,
1275 l/h*
S
lo
pe
Distance between sprinklers (m)
9
10
11
12
13
Max. lateral length (m)
Uphill
2%
162
170
176
180
195
1%
180
190
209
216
221
Flat terrain 0
207
220
242
252
273
Downhill
-1%
234
250
264
288
299
-2%
252
270
286
312
325
Nozzle size
2.3 + 1.8,
510 l/h*
S
lo
pe
Distance between sprinklers (m)
9
10
11
12
13
Max. lateral length (m)
Uphill
2%
153
160
165
168
182
1%
171
180
187
204
208
Flat terrain 0
198
210
220
240
247
Downhill
-1%
216
230
242
264
273
-2% 225
250
264
288
299
Nozzle size
2.5 + 1.8,
580 l/h*
S
lo
pe
Distance between sprinklers (m)
9
10
11
12
13
Max. lateral length (m)
Uphill
2%
144
150
154
168
169
1%
162
170
176
192
195
Flat terrain 0
180
190
198
216
221
Downhill
-1% 189
210
220
240
247
-2%
207
220
242
252
273
Nozzle size
2.9 + 1.8,
680 l/h*
S
lo
pe
Distance between sprinklers (m)
9
10
11
12
13
Max. lateral length (m)
Uphill
2%
126
140
143
156
156
1%
144
150
165
168
182
Flat terrain 0
162
170
176
192
208
Downhill
-1%
171
180
198
204
221
-2% 180
200
209
228
234
Nozzle size
3.2 + 1.8,
810 l/h*
S
lo
pe
Distance between sprinklers (m)
9
10
11
12
13
Max. lateral length (m)
Uphill
2%
117
130
132
144
143
1%
135
140
154
156
169
Flat terrain 0
144
160
165
180
182
Downhill
-1%
153
170
176
192
208
-2% 162
180
187
204
221
Nozzle size
3.5 + 1.8,
940 l/h*
S
lo
pe
Distance between sprinklers (m)
9
10
11
12
13
Max. lateral length (m)
Uphill
2%
108
120
121
132
130
1%
117
130
132
144
156
Flat terrain 0
126
140
143
156
169
Downhill
-1%
135
150
154
168
182
-2% 144
160
165
180
195
Nozzle size
3.5 + 2.5,
1135 l/h*
S
lo
pe
Distance between sprinklers (m)
9
10
11
12
13
Max. lateral length (m)
Uphill
2%
108
110
121
120
130
1%
108
120
132
132
143
Flat terrain 0
117
130
143
144
156
Downhill
-1%
126
140
143
156
169
-2% 135
150
154
168
182
Nozzle size