8
D-Net 6550
TM
USER MANUAL
Sprinkler water trajectory
A
B
A. Distance
- Distance of max. trajectory height from sprinkler nozzle.
B. height
- Elevation of max. trajectory height above ground.
Trajectory height above sprinkler nozzle
The maximum trajectory height above the sprinkler nozzle is relevant in the following cases:
•
When sprinklers are used under the canopy to prevent wetting the foliage.
•
When sprinklers are used in a net-house or inside a roofed structure such as a glasshouse, to prevent
wetting the net or the ceiling.
TECHNICAL DATA
*Nominal flow rate at 2.5 bar working pressure.
Nozzle
Working
pressure
(bar)
Trajectory (m)
Size
(mm)
Color
code
Height Distance
2.3
Gray
2.0
0.8
5.0
2.5
0.9
5.6
3.0
1.1
6.2
2.5
Purple
2.0
0.8
5.2
2.5
1.0
5.8
3.0
1.1
6.3
2.9
Orange
2.0
0.9
5.3
2.5
1.0
6.0
3.0
1.2
6.5
Water trajectory angle: 14 degrees
Head loss in riser tube
Riser tube: OD 12.0 mm
, ID 9.0 mm
Riser
tube
length
(m)
Flow rate* (l/h)
355
400
510
Head loss (bar)
1.2
0.046
0.057
0.087
Riser tube: ½"
, ID 15.0 mm
Riser
tube
length
(m)
Flow rate* (l/h)
355
400
510
Head loss (bar)
0.4
0.001
0.002
0.003
0.8
0.003
0.003
0.005
1.2
0.004
0.005
0.008