Spin Klin
–
System Maintenance
Monthly Maintenance
Check inlet /outlet pressures:
In case the pressure differential is above 5 m / 7 PSI.
Activate automatic back-flush of the Spin Klin filter battery.
If the pressure differential remains high check for possible failures.
Check for leakages from the drain manifold:
In case there is a leakage of water during the filtration stage, check for possible failure at the back-flush valve seals.
Back-flush controller performance:
Check that the controller timing parameters are correctly adjusted and activate automatic back-flush cycle. In the event
of possible failure at the back-flush controller, check for possible failures.
Cleaning of the Command Filter:
Close the command filter inlet valve, release the pressure trapped at the command filter and remove the cover.
Thoroughly clean the filtration element and then reinstall the command filter element and cover, then open the inlet
valve.
Winterization:
To prevent the filter battery becoming damaged during water freezing - drain all the water from the filter battery and the
command filter and leave the drain valve open.