Netafim AQUA PRO Manual Download Page 4

3

Programm

ing the

 

AQUA PRO

:

Press and hold 

<MODE>

 

2

 

Seconds

      Once - set clock and dait

Twice - 

P1

. 3 times - 

P2

. 4 times -

P3

     

Increase

      

Decrease

 blinking digit.

<SET>

 - Sets the entry and proceed.

To select an active program:

Press the 

<MODE> 

button

briefly: Once for P1.

 Twice for P2. 3 times for P3

Four times for 

OFF

.

        Manual Operation:

To start: press      & 

<SET>

To stop:  press      & 

<SET>

P1. -

Once daily at same time.

P2. -

Once daily on selected days.

P3. -

Up to 3 irrigations per day:

e.g. 1, 3, 5, 7,

 Active Days.

Low

battery

Irrigation

duration.

start time.

Programm

ing the

 

AQUA PRO

:

Press and hold 

<MODE>

 

2

 

Seconds

      Once - set clock and dait

Twice - 

P1

. 3 times - 

P2

. 4 times -

P3

     

Increase

      

Decrease

 blinking digit.

<SET>

 - Sets the entry and proceed.

To select an active program:

Press the 

<MODE> 

button

briefly: Once for P1.

 Twice for P2. 3 times for P3

Four times for 

OFF

.

        Manual Operation:

To start: press      & 

<SET>

To stop:  press      & 

<SET>

P1. -

Once daily at same time.

P2. -

Once daily on selected days.

P3. -

Up to 3 irrigations per day:

e.g. 1, 3, 5, 7,

 Active Days.

Low

battery

Irrigation

duration.

start time.

Stick your
language sticker
on the inside
cover.

Table of contents:

Installation
Controller Keyboard
Controller Icons & Display
Electric valve control button
Battery Insertion or replacement
Installation into the watering system
Programming steps
Set P1
Set p2
Set P3
Programming guide table
Controller display in operating mode
Technical information
Warranty

4

5
6
7
8
9

10
11
12
14

15

E

Summary of Contents for AQUA PRO

Page 1: ...www netafim com All right reserved to netafim Hendelmade 0901 ...

Page 2: ...o opcional en f ario programad READ KEEP The smart valve with 3 Independent programs 2 extra modes All right reserved to netafim Hendelmade 0901 ...

Page 3: ...ay Factory preset 15 minutes at 06 00 A M P2 Once a day at the same time on selected Active days P3 Up to three start times per day on selected days Extra Modes OFF stops all irrigation activities Manual to start stop a program manually Start press both SET and keys Stop press both SET and keys Automatic stop when the duration time of the active program P passes Waterproof I P 67 Contains a backup...

Page 4: ...times P2 4times P 3 Incre ase Decre aseblinkingdigit S E T Sets theentryandpro ceed Toselectanactivepro gra m Pre ssthe M O D E button briefly OnceforP1 TwiceforP2 3timesforP3 FourtimesforOFF M anualOpera tion To start pre ss S E T To stop pre ss S E T P1 O ncedaily atsa metime P2 O ncedaily onse lecteddays P3 U pto 3irrigationsperday e g 1 3 5 7 ActiveDays Low battery Irrigation dura tion start t...

Page 5: ...se program values Decrease program values Controller Icons Display Days represented by the digits 1 7 Chosen day is framed Current day is blinking Hours represented in 24 hours format P1 P2 or P3 operating modes Set current time and day 4 Manual irrigation Low battery Irrigation duration start time e g 1 3 5 7 Active Days P3 3 start times per day E ...

Page 6: ... arrow is in Close position the AQUA PRO will remain closed If the override button marked with a red arrow is in Open position the AQUA PRO will remain open Flow Control Flow Direction see page 7 5 Electric valve control buttons Auto Close Open E ...

Page 7: ... battery sign appears insert or replace the battery To insert or to replace the battery 1 Release the four screws of the battery compartment cover 2 Gently remove the cover seal and screws Take care to keep the screws and seal in a safe place 3 Insert replace a new battery 4 Replace the seal cover and screws 5 Tighten the screws E ...

Page 8: ...ng sure that the water flow is in the direction of the arrow on the base of the valve 3 Turn on the main water supply 4 You can control the flow using the Flow Control lever on the base marked from to Installation into the watering system When installing the AQUA PRO hold the valve only E ...

Page 9: ...time and day Press MODE for 2 seconds 1 Use or keys to adjust MINS 2 Press SET to continue 3 Use or keys to adjust HRS 4 Press SET to continue 5 Use or keys to select day of the week 6 Press SET Clock setting is completed Important If no key is pressed for more than 30 seconds during programming the controller resumes operating mode E ...

Page 10: ...ation duration 7 Use or keys to adjust MINS 8 Press SET to continue 9 Use or keys to adjust HRS 10 Press SET to continue Set irrigation starting time 11 Use or keys to adjust MINS 12 Press SET to continue 13 Use or keys to adjust HRS 14 Press SET to continue P1 programming is completed E ...

Page 11: ...hange irrigation duration and or start time go back to P1 7 14 Press MODE three times for 2 seconds 15 Press to activate day 1 16 Press to deactivate day 1 17 Press SET to continue to day 2 18 Press to activate day 2 19 Press to deactivate day 2 20 Set in a similar way days 3 4 5 6 7 P2 programming is completed day 1 ÒblinksÓ 10 E ...

Page 12: ...ration for follow the instruction of P1 7 14 22 Set in a similar way for and 23 To Select active days follow the instruction of P2 15 20 P3 programming is completed Note To select an active program press the MODE button briefly once for P1 twice for P2 three times for P3 and four times to turn the controller OFF E ...

Page 13: ... 4 5 6 7 Active day x x x x x x x Duration 0 15 Start time 08 00 Day 1 2 3 4 5 6 7 Active day x x x x Duration 0 15 Start time 08 00 Example P2 Hour 08 00 13 00 18 00 Day 1 2 3 4 5 6 7 Active day x x x x Duration 0 15 0 15 0 15 Start time 1 2 3 Example P3 E ...

Page 14: ...ay 1 2 3 4 5 6 7 Active day Duration Start time 13 Your program guide table P1 Day 1 2 3 4 5 6 7 Active day Duration Start time P2 Hour Day 1 2 3 4 5 6 7 Active day Duration Start time P3 x x x x x x x E ...

Page 15: ...H 0 1 to 26 GPM Minimum pressure 0 2 BAR 3 PSI Maximum pressure 10 BAR 150 PSI Valve cable 0 6 M connected to the Controller Maximum extension from the valve to the Controller 100 M 330 feet cable 1 0mm Ø AQUA PRO controller is compatible also with Aquanet 1 5 2 D C Operating Temperature 0 to 50 C 32 122 F Storage Temperature 10 to 60 C 14 140 F E ...

Page 16: ... mechanical causes e g lawn mowers Netafim is not liable for indirect incidental or consequential damage in connection with the use of equipment To receive warranty benefits customers should return defective parts to the nearest Netafim distributor Netafim reserves the right to alter modify or redesign its products pricing and warranty at all times without creating any liability for the obsolescen...

Reviews: