NET145LA/NET145CL User
’s Manual Rev1.0B
13
© 2004 NET GmbH. All rights reserved
5.2.2 Command List
Figure 9. Serial Command List
• After booting, the camera sets data of [0].
5.3 Command Description
(1) R_SHUT_SPEED
Controls Random shutter speed
Example : When sets Random shutter speed to 1/120 sec
NET145LA : \002050\003
NET145CL : Z050M
Control Item
Command
Description
CODE
TYPE
D
A
T
A
R_SHUT_SPEED
05
0
-
1/120sec
05
1
-
1/250sec
05
2
-
1/500sec
05
3
-
1/1000sec
05
4
1/2000sec
05
5
1/3000sec
05
6
1/4000sec
05
7
1/8000sec
N_SHUT_SPEED
04
0
-
1/15sec
04
1
-
1/30sec
04
2
-
1/60sec
04
3
-
1/120sec
04
4
-
1/500sec
04
5
-
1/1000sec
04
6
-
1/2000sec
04
7
-
1/3000sec
04
8
-
1/4000sec
04
9
-
1/8000sec
GAIN
06
0
XX
ADC gain control (00 : 0dB,
FF:+24dB)
(* default : 64) XX = 0x00 ~ 0xFF)
Fine/Draft mode
0E
0
-
Fine
mode
resolution
(normal
shutter mode only)
0E
1
-
Draft mode resolution
Shutter mode
0F
0
-
Normal shutter mode
0F
1
-
Random shutter mode
OFFSET
13
0
XX
ADC Offset control with value xx,
XX=0x00~0xFF
13
1
-
ADC PED control, back to factory
setting
ALL RESET
14
F
-
Factory setting
TX Clock
1C
0
-
Tx clock phase 0
1C
1
-
Tx clock shift by degree of 180
SAVE
F0
0
Y
- Saves the current setting value in
[Y] areas of flashrom.
- Load [Y] area value of flashrom
- Y = 0~ F
LOAD
F0
1
Y
RETUTN
01
F
-
Transfer the current camera setting
value to the serial port.