Secure the UIM faceplate to the MUM200-2 faceplate using the (2) provided beige flathead 
screws.  

 

1.3   Install the MUM200-2 in an IP DSLAM Chassis 

The IPD12000 is a fourteen slot chassis; slots 1-12 are reserved for interface modules (such as the 
SIM2000-24) and slots 13-14 are reserved for MUMs. Although not required for operational 
purposes, if redundancy is desired two MUMs may be installed in the IPD12000, one each in slot 13 
and slot 14. The IPD4000 is a five slot chassis; slots 1-4 are reserved for interface modules and slot 

5 is reserved for a MUM. 
 

z

Align the MUM200-2 with the slot module guides of the chosen slot for installation (either slot 
13 or 14 on the IPD12000 or slot 5 on the IPD4000).  

 

z

Slide the MUM200-2 firmly into the chassis. DO NOT USE EXCESS FORCE.  
 

z

Tighten the fastening screws on the MUM200-2 faceplate.  

 

z

Verify that the PWR (Power) LED on the MUM200-2 faceplate is illuminated.  

 

 

1.4   Connect the UIM(s) to the Network 

Connect the network line(s) according to the UIM model type(s) installed in the MUM200-2: 

 
 

1.4.1   UIM-10/100

 

Plug your Ethernet cable into the RJ45 Ethernet port on the UIM-10/100 faceplate. The UIM-
10/100 connects to a router or a PC with a straight-through cable and to a hub or a switch 
with a crossover cable. 
 

Verify the connection: solid illumination of the Lnk (link) LED on the UIM-10/100 faceplate 
indicates an Ethernet uplink connection has been established. The UIM-10/100 Ethernet port 
is 10/100 auto-negotiating. 
 

 

 

1.4.2   UIM-T1 and UIM-E1

 

Plug your T1/E1 cable into the RJ45 T1/E1 port on the UIM-T1 or UIM-E1 faceplate. The UIM-
T1 and UIM-E1 connect to a T1/E1 network extender provider unit (TNE1500-P, TNE1500-P-

12, ENE2000-P or ENE2000-P-12) via T1/E1 line. 
 
Verify the connection: the Lnk (link) LED on the UIM-T1 or UIM-E1 faceplate will flash green to 
indicate a network connection has been established. 

 

 

1.4.3   UIM-DS3 and UIM-E3

 

Plug your DS3/E3 cables into the corresponding Rx and Tx BNC ports on the UIM-DS3 or UIM-
E3 faceplate. The UIM-DS3 and UIM-E3 connect to a DS3/E3 network extender provider unit 
(DNE4500-P, DNE4500-P-12, ENE3400-P or ENE3400-P-12) via DS3/E3 line. 

N

OTE

Net to Net Technologies recommends that the remote device 

with

 which you are connecting be 

configured to auto-negotiate (if applicable) prior to establishing your Ethernet connection. 

220-0000069 rev 04