4.
MAINTENANCE
Always allow the stove to coo before performing any maintenece operation.
Weekly
The de-cocking rod must be operated at least once per week to keep the fuel line free of sediments and dirt. De-
cocking can be done when the stove is turned off or running at minimum setting. Use the tool provided to
unscrew the cap. Then insert the tool into the tube and pull it back and forth in a brisk motion so that any solid
materials lining the inside of the tube will be pushed out. Once you have finished, be sure to screw the cap back
on securely.
Every Two or Three months (depending on use)
Remove the catalyser and clean out any carbon deposits in the base of the burner. Also scrape carbon deposits
from where the oil enters the burner. If necessary, use a glass cleaning solution to wash the glass. Replace
catalyser on its support in the burner.