background image

7

terMInaLs

+12v / 0v

10~15VDC power input terminals

aLarM

Two terminals for the alarm output. Normally 
closed alarm contacts are open circuit in alarm 
condition.

taMPer

Two terminals for the mechanical tamper 
switch operated by the front cover. Normally 
closed contacts are open circuit when the front 
cover is removed.

LIgHt In

Provides external control of the night-light.
Pull low to 0V (negative) to activate the 
night-light at any time.
This terminal can be driven by an output from 
a control panel such as Ness D8x/D16x, Smart-
Living or M1.

sens out

Indicates the status of the light sensor. The out-
put is on when the night-light’s programmed 
darkness threshold is reached.
The output will activate even if the night-light is 
disabled.
This is an open collector output and pulls low 
to 0V (negative) when active. An external pull-
up resistor is required to drive devices such as 
relays.
Dark threshold is controlled by the Light Level 
dipswitch.
This output may be connected in parallel with 
Sensor Out terminals on other LUX PIRs if 
required.

the output is oFF

 when the room is illumi-

nated. Eg Daytime, or light ON

the output is on

 (pulls to 0V) when the room 

is dark.

Fast out

This output indicates movement in the protect-
ed area, regardless of the pulse count setting.
This is useful for home automation and light 
control where a normal security PIR may react 
too slowly.
This is an open collector output and pulls low 
to 0V (negative) when active. An external pull-
up resistor is required to drive devices such as 
relays.
The output may be connected in parallel with 
the Fast Alarm terminals on other LUX PIRs if 
required.
Activation speed is independent of the Pulse 
dipswitch setting, ie, pulse count is always one 
for fast response.

the output is oFF

 when there is no move-

ment in the protected area.

the output is on

 (pulls to 0V) when move-

ment is detected in the protected area.

+12v

This terminal is directly connected to the +12V 
power input terminal and can be used to con-
nect pull-up resistors for the Sensor Out and 
Fast Alarm Out terminals if required.

Summary of Contents for LUX

Page 1: ...activated night light Adjustable Digital Pulse Count Adjustable Digital Range High R F and E S D immunity High white light immunity High quality patented Fresnel lens Capsule design with sealed electronics Front cover tamper protection Totally silent solid state relay with high immunity to magnetic fields Optional mounting bracket available REV1 LUX Hardwired Installation Notes Ness LUX wired PIR ...

Page 2: ...ht light only in the dark Ness LUX s capsule design protects sensitive electronic components and provides easy access to the terminals and dipswitches Detection Coverage At the recommended mounting height of 2 1m 2 3m LUX detector coverage is up to 15m HIGH range setting or 12m LOW range setting Pet Aware Mode In Pet Aware mode see Settings the lower detection zones are masked by the sensor mask w...

Page 3: ...sensor do not touch Dipswitches for custom settings Encapsulated design for easy removal and protection of the PCB Tamper switch 3 position sensor mask White night light LED Blue alarm LED also glows behind the lens PIR lens do not paint or cover Vertical creep zone Ambient light sensor PCB locking tabs each side squeeze both tabs to remove the capsule ...

Page 4: ... Remove the capsule to keep it safe while you install the back housing 3 Drill out a cable entry hole at the top of the LUX back housing The cable entry hole hole should be small enough for a tight cable fit to prevent insects entering the sensor The housing has cable channel to allow mounting on hard surfaces with cable entry top or bottom 4 Install the LUX back housing to the wall using four scr...

Page 5: ...on and flips up from the bottom as per the diagrams below Please ensure that the sensor mask is in the correct position for the required mode ie for Pet Aware mode select dipswitch 3 on and move the sensor mask to position 3 Position 1 Normal Detection Mode default Position 2 No Creep Zone Mode Position 3 Pet Aware Mode 3 position Sensor Mask Lift up to adjust ...

Page 6: ...e Alarm LED OFF The Alarm LED is disabled ON The Alarm LED is enabled Default Switch 5 Light Mode Sets the operation of the white night light LED Manual Manual control of the night light using the Light In terminal Auto Automatic operation of the night light Default means the night light will activate when movement is detected in darkness In this mode manual control is also allowed us ing the Ligh...

Page 7: ... Level dipswitch This output may be connected in parallel with Sensor Out terminals on other LUX PIRs if required The output is OFF when the room is illumi nated Eg Daytime or light ON The output is ON pulls to 0V when the room is dark FAST OUT This output indicates movement in the protect ed area regardless of the pulse count setting This is useful for home automation and light control where a no...

Page 8: ...max Sensor Quad element pyroelectric Alarm indication Blue alarm LED Relay output Solid state relay normally closed contacts 100mA max Tamper output Normally closed switch FAST output SENS output Open collector pulls to 0V Neg Light In input Pull low to 0V Neg to activate Night Light White LED with adjustable threshold Dark Dim Light Alarm period 2 seconds Warm up period 30 seconds Operating volta...

Reviews: