SYMPTOM
POSSIBLE CAUSE
REMEDY
Zone light on or long
Zone detection device (eg.
Close door or window.
beeps on arming
reed switch, movement
Find cause of movement
detector) unsecured.
10 beeps upon Arming.
Mains power off. Battery low.
Check plugpack is
Mains light flashing-
plugged in and
Battery light flashing.
power point on or
Call
installation
company.
10 beeps at any time
(as above)
(as above)
(mains/battery light
flashing)
1 long beep during
Invalid keypad entry
Press enter button &
keypad
entry.
re-enter
2 second siren at end
Zone unsecured on
Re-enter premises, disarm
of exit time.
expiry of exit time
system, check zone isolate
memory to determine zone
at fault.
External strobe light
Alarm occurrence since
Check alarm memory to
flashing.
last arming of panel.
determine zone alarmed.
Siren sounding when
Tamper, panic or 24 hour Reset alarm by entering system
disarmed.
zone, or day zone activated.
code. Check panic buttons
(if Installed)-or call
installation
company.
Armed/ monitor light
Monitor mode entered
Exit monitor mode.
flashing
by mistake.
Zone excluded light
A zone has been excluded. Check zone excluded
flashing
memory. Arm panel with all
zones secured.
Tamper light flashing
Tamper unsecured
Call installation company
Alarm memory light
Alarm in memory.
Check alarm memory to see
flashing.
cause of alarm.
Cannot access program
-Panel armed
-Disarm panel first before
mode. -Not using master code.
entering code.
-To enter program
mode
press
Prog-Master code-Enter
(see page 17)
22