16
Installation Manual
Saturn Bm
Placing the telefax (option)
TEL2 is configured for telefax as default.
However, any of the telephone ports can be
configured for telefax.
Max. cable length 150 m, 0.5 mm
2
min.
For connection directly to the MCU, use
telephone cable with grounding tail,
and employ fax adapter.
Placing the PC telex & serial printer (if equipped)
The PC Telex and Printer must be installed
close to the Main Control Unit.
Max. cable length 15 m, 0.5 mm
2
min.
Placing the DTE equipment connected to the DTE port
The equipment must be installed as close as
possible to the Main Control Unit.
Max. cable length 15 m, 0.5 mm
2
min. for ASD
1.5 m, 0.5 mm
2
min. for HSD
Requirements relating to GMDSS power supply
The ship earth station shall normally be powered
from the ship`s main source of electrical energy.
In addition, it shall be possible to operate the
ship earth station and all equipment necessary
for its normal functioning, including the antenna
tracking system, from an alternative source of
energy.
Changing from one source of supply to another
or any interruption up 60 secs of the supply of
electrical energy shall not render the equipment
inoperative or require the equipment to be manu-
ally re-initialized.
If provision is made for operating the equipment
from more than one source of electrical energy,
arrangements for rapidly changing from one
source to the other shall be provided but not
necessarily incorporated in the equipment.