Mechanical Seals 

Pumps equipped with mechanical seals are of the standard pusher bellows type or wedge style. They can be expected to provide long and 
troublefree service provided:  

1) Seal materials are compatible with pumped fluid and properly applied to the service. 
2) Adequate cooling and lubrication is provided 
3) Dry running is avoided 
4) Abrasives are kept away from the seal area 
5) Pump and driver are properly aligned 

 
Detailed mechanical seal inspection and replacement instructions are included with Oberdorfer Repair Kits. 

 

Lip Seals 

Pumps equipped with lip seals are of the metal cased, spring energized, single lip style. These are intended to provide minimum friction drag 
with positive sealing and again should be maintenance free provided the same conditions for mechanical seals are met as well as: 

6) Avoid scouring of the shaft in the lip seal area due to contaminated abrasives 
7) Avoid excessive seal lip contact pressure on the pump shaft due to excessive pump pressure. 
    These are readily replaceable by pressing out the old seal and pressing in a new replacement. 

 

Packing 

Pumps equipped with teflon or graphoil packing require periodic adjustment as described above in the Startup section to avoid excessive 
leakage. Eventually all the packing in the pump will become deteriorated and will have to be replaced. 

 

Recommended Spares 

Repair kits are available for all Oberdorfer Bronze Gear Pumps. Each kit comes with detailed instructions. For the proper kit, contact your 
Oberdorfer Distributor or the factory. 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for G-100-1A

Page 1: ...NEPTUNE GLYCOL FEED SYSTEM Models G 50 1 G 50 1A G 50 2A G 100 1A G 100 2A Lansdale PA 19446 Tel 215 699 8700 Fax 215 699 0370 REV NO 6 01 08 04 ZL106838 OPERATING INSTRUCTION MANUAL...

Page 2: ...pm pump float switch and NEMA 4X control panel The control panel features a HAND OFF AUTO selector switch for the pump motor ON indication light for the pump LOW tank level indication light and power...

Page 3: ...stop the pump The minimum differential pressure between the cut in and cut out set points is 10 psi and the maximum is 30 psi The float switch in the bottom of the tank will stop the pump if the glyc...

Page 4: ...and the other in a clockwise rotation Looking at the front of the Model G XX 2A the control panel facing you the pump motor on the left should be wired counter clockwise and the pump motor on the rig...

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...may be readily inspected in the field usually without removal from the drive or system plumbing Simply remove the cover screws to pull the cover Before attempting an inspection follow safety precauti...

Page 9: ...positioned for easy cleaning access If start up screens are used be sure they are removed prior to placing the system into regular operation Orient lines so as to prevent formation of air pockets Be s...

Page 10: ...ions require no adjustment If the pump s bearing areas or seal area runs hot shut the pump down and determine the cause For units equipped with integral pressure relief valve the factory setting is us...

Page 11: ...inimum friction drag with positive sealing and again should be maintenance free provided the same conditions for mechanical seals are met as well as 6 Avoid scouring of the shaft in the lip seal area...

Page 12: ...ut out 50 psi Differential 20 psi 50 30 psi Range The range is the pressure limits within which the operating points settings can be adjusted The range of the Class 9013 pressure switch is referenced...

Page 13: ...st the operating points 1 Place a flat blade screwdriver in a range adjustment nut slot 2 Rotate the nut to the left to increase the operating points or to the right to decrease the operating set poin...

Page 14: ...Cracking will not occur if the bushing is FIRST tightened into the pipe or tank fitting and THEN the L 30 body is tightened into the bushing Thus 1 Teflon tape thread and tighten plastic bushing into...

Page 15: ...ation and thread gland nut firmly on to cover Fig 1 Wiring schematic for power applied to load when liquid level is less than set point power to load interrupted when level increases to above set poin...