your PAR falls below a certain value, you would add this to your email outlet, substituting a 
PAR value that makes sense for your tank: 
 
If PAR < 250 Then ON 
 
If you wanted to limit this to only daytime, then you could create a virtual outlet for the 
purpose and use this programming. 
 
[ PAR_Check ] 
Set OFF 
IF PAR < 250 Then ON 
If Time 18:00 to 08:59 Then OFF 
 
Then you would simply check if the virtual outlet is ON (if PAR is lower then expected) in 
your email outlet program by adding a program statement like this: 
 
If Outlet PAR_Check = ON Then ON 
 
Your PAR probe can alert you indirectly to several conditions in your tank that you might 
find helpful.  For example, a reduction of PAR over time could indicate: 

 

Algae growth 

 

Bulbs that need replacing 

 
The PAR sensor readings can also be used to alert you if: 
 

 

Your lights are off when they should be on 

 

Your lights are on when they should be off 

 
You can also use your PAR sensor as a real-time measurement of your lighting spectrum 
and intensity.  With the advanced graphing capabilities of APEX Fusion, you can 
superimpose your PAR readings during the day with your lighting schedule in Fusion using 
the ‘Compare’ option.  As you experiment with different color combinations (assuming you 
have LED lighting) and intensities you can see the impact on PAR and analyze the resulting 
effect on your livestock.   