13
- GB -
Start-up
Attention! Dangerous electrical voltage.
Possible consequences:
Death or severe injury.
Protective measures:
•
Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the
water.
•
Isolate the unit before starting any work.
•
Secure the unit to prevent unintentional switching on.
Attention!
Never operate the unit with a water pressure of more than 0.2 bar!
C
Important:
•
Switch the pump on first, then the UVC clarifying unit.
•
Do not operate the unit without water flowing through.
•
The unit switches on automatically when power connection is established.
Switching on:
Connect power plug to the socket.
•
The control lamp is lit.
Note:
•
After a new installation, the unit only reaches its full biological cleaning effect after a few weeks.
•
The full effect on bacteria is only reached as from a water temperature of + 10 °C.
•
In the event of overheating, the installed temperature monitor switches the UVC lamp off automatically, the lamp
automatically switches on again once cooled down.
Check all connections for leaks.
Switching off:
Disconnect the power plug.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences:
Death or severe injury.
Protective measures:
•
Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the
water.
•
Isolate the unit before starting any work.
•
Secure the unit to prevent unintentional switching on.
Note:
•
Check and clean the water outlet into the pond at regular intervals.
•
Clean the filters at regular intervals (e.g. every four weeks), however, at the latest when cloudy or dirty water from
the water outlet returns to the garden pond.
•
Carry out quick cleaning first. Should this prove insufficient, clean the entire unit.
•
A blocked filter could lead to leakages.
•
Never use chemical cleaning agents.
Quick cleaning
D
•
Switch off the filter pump.
•
Remove hose from the filter outlet by turning off the union nut (1).
•
Remove hose from the filter inlet by turning off the union nut and screw on the filter outlet (2).
•
Screw a dirt drain hose with stepped hose adapter on the filter inlet.
•
Switch on the filter pump.
•
Vigorously pull on the cleaning handle and „pump“ several times (3). In this manner, the foam filters are mechani-
cally cleaned until the draining water is clear.
•
Switch off the filter pump.
•
Remove the dirt drain hose and correctly reconnect the hoses for normal operation (Figure A).
Full cleaning
E
•
Disconnect all hoses by turning off the union nuts (1).
23583-01-14_GA_Druckfilter_NCTF-13 13
30.01.2014 13:34:10
Summary of Contents for Classic NCTF-O 5000
Page 2: ...2 A PPS0011 B PPS0013 C PPS0014 23583 01 14_GA_Druckfilter_NCTF 2 2 30 01 2014 13 34 07 ...
Page 3: ...3 D PPS0012 E PPS0015 23583 01 14_GA_Druckfilter_NCTF 3 3 30 01 2014 13 34 07 ...
Page 4: ...4 F PPS0025 23583 01 14_GA_Druckfilter_NCTF 4 4 30 01 2014 13 34 09 ...
Page 117: ...23583 01 14_GA_Druckfilter_NCTF 117 117 30 01 2014 13 34 15 ...
Page 118: ...23583 01 14_GA_Druckfilter_NCTF 118 118 30 01 2014 13 34 15 ...
Page 119: ...23583 01 14_GA_Druckfilter_NCTF 119 119 30 01 2014 13 34 15 ...