NEP PVG-4 Installation And Operation Manual Download Page 6

8  

9  

7. SPECIFICATION 

 

MODEL 

PVG-n 

INPUT(DC) 

Max Recommended PV Power 

 

450(*n) 

Max DC Open Circuit Voltage 

 

80 per input 

Max DC Input Current (Adc) 

14 

OUTPUT(DC) 

Maximum Output Power (Wp) 

0 ~ 450(*n) 

Maximum Output Current 

 

14 

Maximum Output Voltage 

 

0 ~ Voc(*n) 

SYSTEM   

Maximum System Voltage 

 

600/1000/1500 

Maximum Series Fuse Rating 

 

15 

PROTECTION 

Protection Degree 

NEMA-6 

Ambient Temperature 

-40

C

——+85

C

 

Display 

LED LIGHT 

Communications 

DC Power Line 

Product Safety Compliance 

NEC 2014/2017 690.12 

 
8. Mark 

The following label shall be permanently placed close to the PVG-C remote controller.

 

 

 

Summary of Contents for PVG-4

Page 1: ...F TEL 81 092 433 3252 FAX 81 092 433 3171 China Address No 1 Anhe Rd Tsingtao Export Processing Zone Tsingtao China 266113 TEL 86 532 87963900 FAX 86 532 81100917 Email info northernep com Web http www northernep com http www nep japan com http www micro inverter jp Installation and Operation Manual PVG 4 Rapid Shutdown Device ...

Page 2: ...unity and powered by electricity from solar wind and micro turbines Outside China the company has operation offices in Chicago U S and Vancouver Canada The technology founders of the company are well known experts in the fields of power electronics automatic control signal processing and communications Each of the founders has multiple U S and world patents in their specialty areas They received P...

Page 3: ...damage to the environment CE mark The product complies with essential requirements of relevant directives of EU 2 SAFETY INSTRUCTION WARNING PLEASE READ THIS MANUAL BEFORE INSTALLATION ANY DAMAGE TO THE PRODUCT DUE TO NOT FOLLOWING THIS MANUAL IS NOT COVERED BY THE WARRANTEE ALL THE INSTALLATION SHOULD BE DONE BY CERTIFIED ELECTRICIAN BESIDES THE CABLE CONNECTORS NOTHING INSIDE THE PRODUCT SHOULD ...

Page 4: ...4 5 PVG 4 System Diagram ...

Page 5: ...N 10 SECONDS PVG is powered by the PV panel Thus the rapid shutdown is operable during daytime when the PV panel is energized Rapid shutdown can be activated by one of the following two operations Option 1 Press the E STOP button on the PVG controller PVG C Option 2 Disconnect AC adapter to the PVG C remote controller Flashing LED on the PVG 1 2 3 4 indicates the status of the switch inside the PV...

Page 6: ...n Maximum Output Current 14 Maximum Output Voltage 0 Voc n SYSTEM Maximum System Voltage 600 1000 1500 Maximum Series Fuse Rating 15 PROTECTION Protection Degree NEMA 6 Ambient Temperature 40C 85C Display LED LIGHT Communications DC Power Line Product Safety Compliance NEC 2014 2017 690 12 8 Mark The following label shall be permanently placed close to the PVG C remote controller ...

Reviews: