DS103 Neox Display technical specifications
48
DATA CLEARANCE
10 seconds within display turned on, and speed is 0, long press
🄼
(2 seconds) enter the
data clearance interface, short press
🄼
to clearance trip mileage(TRIP), riding time(TRIP
TIME),average speed(AVG) and maximum speed(MAX). Then display pop up the confir-
mation window, short press
🄼
again to clearance all listed items. Display will return to
riding interface without data clearance if no operation in 10 seconds.
Shown the data clearance interface as below:
ERROR INFORMATION
Nr. Status
data
Description
Note
1
0x01 Normal status
LED of controller is on
2
0x03 Already brake
Display will not show
3 0x04
Torque sensor
4 0x05 Throttle error
5 0x06 Under voltage protection
Display will not show
6
0x07 Over voltage protection
7 0x08 Hall signal error of motor
8 0x09 Phase wire error of motor
9
0x10 Temperature of motor reaches the protect temperature
10
0x11 Temperature sensor of motor error
11
0x12 Current sensor error
12
0x13 Temperature error inside battery
13 0X14 Temperature of controller reaches the protect temperature
14 0X15 Temperature sensor of controller error
15
0x21 Speed sensor error
16 0x22 BMS communication error
Display can’t get the information, will not
show the code
17 0x23 Front light error
18 0x24 Light sensor error
19 0x25 Torque signal error from torque sensor
20 0x26 Speed error from torque sensor
21 0x30 Communication error
Display will check communication error
automatically, controller will not send this
message