background image

OPERATING   INSTRUCTIONS   conEnued      

6   

SWING:

      

The   louvre   automa6cally   turns   to   upright   posi6on   when   the   appliance   is   first   turned   ON.      

Press   once   and   the   air   louvre   will   move   from   90°   upright   posi6on   to   45°   to   aid   
clothes      drying;   the   SWING   LED   will   illuminate.      Press   again   and   the   air   louvre   will   

return   to   the   90°   angle   and   the   SWING   LED   turns   off   .   

   

TIMER:   

Press   the   TIMER   buAon   through   the   sequence   below.   

   
   

   

   
   

Press   the   TIMER   buAon   to   set   running   hours   (1,   2,   4   or   8   hours).      When   the   6mer   is   set   the   

corresponding   LED   will   illuminate   displaying   the   6me   sejng.      

   

   

ION:   

Ionizers   use   electricity   to   create   nega6ve   electrons.   These   electrons   stream   into   the   air   and   

aAract    oxygen    molecules.    At    this    point,    they    become    nega6ve    ions    and    are    aAracted    to   
airborne    par6cles.    These    molecules    build    up    around    the    par6cles    un6l    they    become    too   

heavy   to   remain   air   borne   and   float   to   the   ground.   
   

ALARM:

   

The   alarm   will   sound      and   the   ALARM   LED   will   illuminate   if   a   malfunc6on   is   detected.      The   
appliance   will   shut   down   automa6cally   if   the   internal   temperature   is   too   high.      Disconnect   

the   appliance   from   the   mains   socket   outlet   and   wait   for   15   minutes   before   re-­‐connec6ng   
the    appliance    to    the    mains    socket    outlet    and    con6nuing    with    normal    opera6on.        If    the   

alarm    fault    con6nues;    contact    your    authorised    service    agent    immediately    for    further   

advise.   

   

1   Hour   

2   Hours      

4   Hours      

8   Hours

      

In    CONTINUOUS    opera6on    the    desiccant    wheel    will    operate    to    remove    ALL    moisture   

present   in   the   air   &   fabric   of   the   building.   At   40%,   50%   &   60%   the   appliance   will   operate   

to   achieve   the   set   humidity.      Once   achieved,   the   desiccant   wheel   will   stop   opera6ng   un6l   
the   rela6ve   humidity   rises   above   the   set   humidity.      

Summary of Contents for M947015

Page 1: ...Rotary Desiccant Dehumidifier Item No M947015 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Page 2: ...tailer DO NOT leave children unaAended with any of the packaging since it is a poten6al source of danger Disposal of all packaging must be carried out responsibly safely and in accordance with your lo...

Page 3: ...The desiccant dehumidi er is designed to provide an op6mum opera6ng performance between 1 C and 37 C To achieve maximum e ciency keep doors and windows closed When rst used or periodically a erwards...

Page 4: ...e appliance or allow objects to obstruct the inlet or outlet openings or operate in close proximity to walls or curtains etc 8 The use of attachments or accessories not recommended or sold by the prod...

Page 5: ...DESCRIPTION Con6nuous drain 2m hose included Return air Dry Air intake Humid Auto air louvre 4 DO NOT OBSTRUCT THE AIR INLET OR OUTLET Power cable Control panel condensate tank Air Filter Filter Rele...

Page 6: ...ontrol the fan speed through the sequence below L Low M Medium H High The corresponding LED will illuminate on the control panel and side panel TROL PANEL OPERATING INSTRUCTIONS Low Medium High CONTIN...

Page 7: ...d to airborne par6cles These molecules build up around the par6cles un6l they become too heavy to remain air borne and oat to the ground ALARM The alarm will sound and the ALARM LED will illuminate if...

Page 8: ...pillage should be dried immediately to avoid a poten6al hazard Emptying the condensate Tank ConEnuous Drain OpEon 1 Ensure the appliance is unplugged from the power supply socket 2 Remove the condensa...

Page 9: ...liance is disconnected from the mains power outlet Remove the lter located at the back of the appliance by pulling the lter tab and slide out Clean the lter using clean water and allow to dry Alterna6...

Page 10: ...te The appliance will stop dehumidifying automa6cally The dehumidifying process will only restart once the condensate tank and been emp6ed and re installed Once re installed correctly the LED will tur...

Page 11: ...ying the terminals in your plug proceed as follows 1 The BLUE wire is the NEUTRAL and must be connected to the terminal that is marked with the leAer N or coloured BLACK 2 The BROWN wire is the LIVE a...

Page 12: ...y place V Repairs should only be carried out by a quali ed service agent VI DO NOT modify the appliance or use in a manor not originally intended Item No Model No M947015 YL 208B Power Supply 230 240V...

Page 13: ...ely event of a problem please visit our website www neostar electronics co uk and read our FAQs section and if needed contact our UK customer Support desk on 0344 482 1414 Imported by Scotts Co Ltd SN...

Page 14: ...FAQs 13...