Page 25
Indoor Unit
Installation
Move to left or right
30-50mm
(1.2-1.95in)
30-50mm
(1.2-1.95in)
UNIT IS ADJUSTABLE
Keep in mind that the hooks on the mounting
plate are smaller than the holes on the back of
the unit. If you find that you don’t have ample
room to connect embedded pipes to the indoor
unit, the unit can be adjusted left or right by
about 30-50mm (1.25-1.95in), depending on
the model.
Step 8: Mount indoor unit
If you installed new connective piping to the
outdoor unit,
do the following:
1.
If you have already passed the refrigerant
piping through the hole in the wall, proceed
to Step 4.
2.
Otherwise, double-check that the ends of the
refrigerant pipes are sealed to prevent dirt or
foreign materials from entering the pipes.
3.
Slowly pass the wrapped bundle of refrigerant
pipes, drain hose, and signal wire through the
hole in the wall.
4.
Hook the top of the indoor unit on the upper
hook of the mounting plate.
5.
Check that unit is hooked firmly on mounting
by applying slight pressure to the left and
right-hand sides of the unit. The unit should
not jiggle or shift.
6.
Using even pressure, push down on the
bottom half of the unit. Keep pushing down
until the unit snaps onto the hooks along the
bottom of the mounting plate.
7.
Again, check that the unit is firmly mounted
by applying slight pressure to the left and the
right-hand sides of the unit.
If refrigerant piping is already embedded in
the wall,
do the following:
1.
Hook the top of the indoor unit on the upper
hook of the mounting plate.
2.
Use a bracket or wedge to prop up the unit,
giving you enough room to connect the
refrigerant piping, signal cable, and drain
hose.
3.
Connect drain hose and refrigerant piping
(refer to
Refrigerant Piping Connection
section of this manual for instructions).
4.
Keep pipe connection point exposed to
perform the leak test (refer to
Electrical
Checks and Leak Checks
section of this
manual).
5.
After the leak test, wrap the connection point
with insulation tape.
6.
Remove the bracket or wedge that is propping
up the unit.
7.
Using even pressure, push down on the
bottom half of the unit. Keep pushing down
until the unit snaps onto the hooks along the
bottom of the mounting plate.
Summary of Contents for NS/NU-09EHBI
Page 1: ...NS NU 09EHBI NS NU 12EHBI NS NU 18EHBI NS NU 24EHBI...
Page 2: ...2 5 7 12 13 15 17 3...
Page 3: ...R32 1 3...
Page 4: ...2 18000 24000 35 2 12000 18000 26 2 9000 12000 17 2 9000 13 R32 2 4 2 4 R32 1 4...
Page 5: ...5 8...
Page 6: ...6...
Page 7: ...7...
Page 9: ...9 Wi Fi Wi Fi Wi Fi COOL AUTO COOL DRY EC LED TURBO...
Page 10: ...10 2 2 SWING DIRECT 1 SWING DIRECT 6 2 SWING DIRECT 3 2 3 2 3 COOL DRY 2 2 COOL HEAT...
Page 11: ...11 SLEEP SLEEP COOL 1 C 2 F 1 1 C 2 F HEAT 1 C 2 F 1 1 C 2 F 7 SLEEP FAN DRY 1 1 7...
Page 13: ...13 5 1 Plasma 10 40 C 104 F 1 2 3 4 5 6 7...
Page 14: ...14 240 CL 15 4 LED 3 CL 2 880 nF 15 4 LED 3 nF FAN...
Page 15: ...15 3 HEAT HEAT ON OFF COOL HEAT FAN...
Page 16: ...16 ON OFF SILENCE SILENCE SILENCE...
Page 17: ...17 3 3 7 C 44 5 F 10 E0 E1 E2 P1 P2 P3 F1 F2 F3...
Page 18: ...NS NU 24EHBI NS NU 18EHBI NS NU 12EHBI NS NU 09EHBI...
Page 20: ...20 ST2 9 10 AAA LR0...
Page 21: ...21 11 12 12 12...
Page 22: ...22 18 18 25 17 14...
Page 23: ...23 3 1...
Page 24: ...1 24...
Page 25: ...25 2 3 1 1 65 2 5 2 2 65 2 5 5 7 0 2 0 275 4 2 3 3 5 0 2 2 3 90 55 4 1 12 4 75 15 5 9 12 4 75...
Page 26: ...4 2 4 3 26...
Page 27: ...27 4 30 50 1 25 1 95 4 5 4 4 3 4 5 6 7 1 2 3 3 1 30 50 1 2 1 95 4 4 4 5...
Page 28: ...28 4 5 6 7 3 15 6 5 1 2 3 4 5 3 3...
Page 29: ...29 3 5 7 1 8 9 2 3 10 11 1 40 4 90 100 5 1 5 6 1 8 3...
Page 31: ...7 U 2 3 3 12 8 9 8 1 4 2 3 4 5 6 7 7 1 3 12 3 12 31...
Page 32: ...32 1 4 1 4 1 4 1...
Page 33: ...33 4 4 1 2 3 90 4 4 4 B 1 2 90 4 2 4 3 2 4 2 4 3 4 4...
Page 35: ...35 1 2 3 4 90 100 5 1 5 6 1 8 3 7 8 9 10 11 1 40 1 2 3 4 5 6 7 4...
Page 40: ...40 1 5 9 2 3 4 5 10 5 6 7 3 6 5 9 5 10...
Page 41: ...41 1 2 6 1...
Page 43: ...43 4...
Page 44: ...44 COOL HEAT 30 1 2 ON OFF 3 MODE COOL HEAT 4 5...