8. FUNCTIONS OF THE BUTTONS
MENU:
Function switching button; then have the
numerical valuechanged by using UP and DOWN
buttons.
•
A.xxx: Setting of DMX address.Range of address
value: address=001~512. Press ”UP” or “Down”
1.5 seconds can change value continuously and
fast, pressed UP/DOWN at the same time, value
back to 1.
•
P.xxx: Setting output of timing fogging and con
-
tinuous Fogging (Puff Volume=5~100%).
•
F.xxx: Setting fan speed of timing fogging and
Continuous Fogging(Fan=5~100%).
•
t.oFF/t.on: Setting Timer ON/OF, switching by
UP and DOWN buttons.
•
d.xxx: Setting duration of timing fogging (Dura
-
tion=3~250s).
•
i.xxx: Setting interval of timing fogging (Inter
-
val=5~250s).
UP:
Button for increasing numerical value
DOWN:
Button for decreasing numerical value
ENTER:
Starting button of fogging, release to stop.
Self-cleaningfunction: The machine design of ma-
chine stops working after a delay of 30 seconds, auto
-
matically clear the tubing of the remaining liquid.
Set values are automatically saved.
REMARK:
To reduce the possibility of that the wind
mouth gets humid, the software will detect the
wind value and the fog value, and do proper adjust
-
ment. Under display control mode (timing fogging,
continuous fogging) or DMX control mode: when
fog value is adjusted to 100%, the software will
adjust wind value (even it is set at 5%) to 30% auto
-
matically; when wind value is adjusted to 5%, the
software will reduce fog value to 50% automatical
-
ly. This will prevent the smoke vent from getting
humid because of too small wind but too much fog.
*Fog value = Puff Volume, wind value = Fan