background image

P. 2

Neo Steam 1500 RGBA -

English version

1. OVERVIEW

STEAM 1500 RGBA

Professional fog machine with RGBA effect

Steam 1500 RGBA 

is a professional 2-in-1 fog ma-

chine that has 28 RGBA 3W LEDs, adding an attrac-

tive visual effect to its original function. Thanks to 

the incorporation of amber LEDs to the classical 

RGB mix, the fixture achieves a very complete and 

attractive color mix, standing out naturally in any 

given situation. With an output of 40,000 cubic feet 

per minute and a 2L (67 Oz.) tank capacity, Steam 

1500 RGBA is itself a high performance fog machine, 

beyond its attractive visual effect. The fixture has 

6 DMX modes (9 DMX channels max) and includes 

a wireless remote control that allows four different 

programs to be run at a distance.

Source & Optics

• 

Light source: 28 RGBA (8R, 7G, 9B, 4A) 3W LEDs

• 

LEDs life: 50,000 hours

Output

• 

Smoke output: 40,000 cubic feet per minute

•  Warm up time: 9 minutes

• 

Tank: 2 lts./ 67 Oz.

• 

Liquid consumption: 150 ml/min / 5 oz/min

Control

•  Operational modes: DMX, Wireless remote con-

trol, LED patterns & manual

• 

DMX channels: 1/2/3/5/7/9

Physical

•  DMX connectors: 2 XLR connectors                

(XLR-3 In & Out)

• 

Remote control connector: 1 TRS/1/4”         

connector

• 

4-digit LED display

• 

Dimensions: 458x307x207 mm. / 18x12x8.1 in. 

• 

Weight: 10.7 Kg. / 23.5 Lbs.

Summary of Contents for STEAM 1500 RGBA

Page 1: ...Neo Steam 1500 RGBA USER MANUAL MANUAL DE USUARIO PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USE POR FAVOR LEA LAS INSTRUCCI NES ANTES DE USAR STEAM 1500 RGBA Professional fog machine with RGBA eff...

Page 2: ...BA is itself a high performance fog machine beyond its attractive visual effect The fixture has 6 DMX modes 9 DMX channels max and includes a wireless remote control that allows four different program...

Page 3: ...ult use Keep out of reach of children Never leave the unit running unattended Fogmachine nozzle gets hot over 200 degrees centigrade during use Don t touch Maintain a safe distance over 100CM Never ai...

Page 4: ...e user manual To avoid any accident it is not allowed to install the product with any way not instructed on the user manual If accident happens because users do not install the product according to th...

Page 5: ...uid Tank D Tank Fixed Cover E Safety Loop F Power Switch G LED display H Menu I Up J Down K Enter L Manual Fog M DMX 3 pin XLR Input N DMX 3 pin XLR Output O Control Socket Connection P Electric Power...

Page 6: ...makes Steam 1500 RGB easier for use 4 GETTING READY All products are thoroughly tested at the factory and shipped in perfect condition If damage has oc curred during shipping or if components are miss...

Page 7: ...P 7 Neo Steam 1500 RGBA Mounting reference English version...

Page 8: ...for color macro setting of each chan nel and DMX address setting ENTER Button for the first layer and the second layer of menu UP Button for increasing numerical value DOWN Button for decreasing numer...

Page 9: ...P 9 Neo Steam 1500 RGBA English version System Menu When shot down the present function status will be saved automatically and continue when powered on next time...

Page 10: ...to working status Heating up it shows HEAt Setting function value is allowed when heating up With no op eration after 4 seconds it goes back to HEAt status 5 Wait about 9 minutes for heating element t...

Page 11: ...vailable wireless control not available Your Steam 1500 RGB is now ready for opera tion with your DMX controller 8 If desired connect another fog machine Plug one end of another signal cable in to the...

Page 12: ...see figure 3 color macro list 160 255 Random Strobe Slow Fast 0 31 OFF 96 159 Pulse Effect in sequence 32 95 Strobe Effect Slow Fast 0 31 Strobe Off CH1 CH2 CH3 CH4 CH5 FOG RED GREEN BLUE AMBER 32 255...

Page 13: ...OFF 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF Value Color Value Color 0 7 OFF 128 135 Red_1 185 Red_2 100 Green_1 55 Green_2 70 Blue_1 233 Blue_2 167 Amber 0 8 15 Red_1 255 Red_2 0 Green_1 0 Gre...

Page 14: ...Blue_1 0 Blue_2 0 Amber 0 192 199 Red_1 0 Red_2 88 Green_1 142 Green_2 48 Blue_1 0 Blue_2 200 Amber 200 72 79 Red_1 0 Red_2 0 Green_1 0 Green_2 0 Blue_1 255 Blue_2 0 Amber 255 200 207 Red_1 255 Red_2...

Page 15: ...carry out following steps If the problem persists refer servic ing to a qualified technician Power Connected but No Fog Is Emitted 1 Check the power supply Plug the unit into grounded electric power...

Page 16: ...ight the cover of the fog machine liquid tank immediately after filling Periodically check the connecions among the oil tube the pump and the heater to see if there s oil leaking If positive lock tigh...

Page 17: ...chine is plugged the red LED on this receiver of remote controller will light up Unplug the power the red LED off Green LED Status indication 1 Warm up the green LED goes out 2 Warm up is completed th...

Page 18: ...machine has completed heating up or not If the red dot is flashing heating is not completed yet and duration of fogging is only 1 3 seconds If the red dot is light ed and does not flash heating is co...

Page 19: ...ada para ser instalada El equipo trabaja en hasta 9 canales DMX e incluye por ltimo un control remoto inal mbrico que permite ejecutar a la distancia cuatro programas diferentes Fuente pticas Fuente...

Page 20: ...e 100 cm de otros objetos o personas No apunte la salida de humo directamente hacia las personas Mantenga la cubierta cerrada durante el fun cionamiento de la unidad Instale la unidad en un ambiente b...

Page 21: ...cisar asistencia p ngase en contacto con el servicio t cnico autorizado Advertencia de instalaci n Procure seguir las instrucciones del manual para instalar el equipo correctamente Evite accidentes No...

Page 22: ...eguridad F Interruptor de encendido apagado G Pantalla LED H Men I Tecla arriba J Tecla abajo K Tecla Enter L Emisi n manual M Entrada DMX XLR 3 N Salida DMX XLR 3 O Conector del control remoto P Cabl...

Page 23: ...entregado en perfectas condiciones Revise detenidamente que el producto no se haya da ado durante el env o En caso de que encuentre da os p nganse en contacto con el distribuidor Montaje Desajuste lo...

Page 24: ...pa ol Mounting reference ratura del calentador hasta cesar la emisi n En caso de que esto suceda no active la emisi n Aguarde unos instantes Una vez que la unidad vuelva a incrementar la temperatura s...

Page 25: ...DMX configuraci n de direcci n DMX y macros de color ENTER Confirmaci n de acceso a las diferentes opciones del men TECLA ARRIBA Incrementa el valor num rico TECLA ABAJO Disminuye el valor num rico Pr...

Page 26: ...se encienda Men Enter arriba abajo arriba abajo 001 512 001 512 arriba abajo arriba abajo 4s de inactivi dad Enter Enter Enter rc 1 rc 4 configuraci n DMX Mode 1 DMX Mode 1 Luego de 4 segundos de inac...

Page 27: ...lenta do En la pantalla ver HEAt Durante el precalentado el usuario podr configurar las funciones normalmente Luego de 4 segundos de inactividad la unidad volver al estado HEAt 5 Aguarde aproximadamen...

Page 28: ...A xxx Aseg rese de configurar el modo DMX y la direcci n DMX deseadas control inal mbrico no disponible A partir de este momento su CF 9 5 est lista para ser operada por un con trolador DMX 8 Si dese...

Page 29: ...N DE HUMO MACROS DE COLOR ESTROBO 32 255 Salida m xima Macro de color 1 29 ver figu ra 3 lista de macros de color 160 255 Estrobo aleatorio velocidad creciente 0 31 Apagado 96 159 Efecto pulse en sec...

Page 30: ...IMMER MAESTRO 32 255 Max Salida 1 255 MIN a MAX 1 255 MIN a MAX 1 255 MIN a MAX 1 255 MIN a MAX 1 255 MIN a MAX 1 255 MIN a MAX 1 255 MIN a MAX 1 255 MIN a MAX 0 31 Apagado 0 Apagado 0 A pagado 0 Apag...

Page 31: ...Azul_1 0 Azul_2 0 mbar 255 184 191 Rojo_1 130 Rojo_2 75 Verde_1 222 Verde_2 170 Azul_1 28 Azul_2 195 mbar 111 64 71 Rojo_1 255 Rojo_2 0 Verde_1 0 Verde_2 255 Azul_1 0 Azul_2 0 mbar 0 192 199 Rojo_1 0...

Page 32: ...hasta lograr resolverlo Una vez solucionado el inconveniente no es necesario continuar con los pasos restantes Si el equipo contin a con incon venientes p ngase en contacto con el servicio t cnico au...

Page 33: ...rlas de inmediato para evitar que ingresen part culas indeseadas Verifique que no haya p rdidas de aceite en los conectores del tubo la bomba y el calentador Si detecta una p rdida utilice una herrami...

Page 34: ...de encendido Una vez encendida la m quina de humo el LED rojo del receptor se encender Al desconectarla el LED rojo se apagar LED verde Indicador de estado 1 Durante el precalentamiento el LED verde e...

Page 35: ...lentado y la duraci n de la emisi n de humo es de 1 3 segundos Si el punto no titila el proceso de precalentado ha finalizado y la duraci n de la emisi n de humo puede alcanzar 8 9 segundos Especifica...

Page 36: ...P 36 Neo Steam 1500 RGBA neo amproweb com...