NEO Sion User Manual Download Page 6

1.5 SAFETY WARNING

IMPORTANT

ALWAYS READ THE USER MANUAL BEFORE OPERATION.

PLEASE CONFIRM THAT THE POWER SUPPLY STATED ON THE

PRODUCT IS THE SAME AS THE MAINS POWER SUPPLY IN YOUR

AREA.

 This product must be installed by a qualified professional.

 Always operate the equipment as described in the user manual.

A  minimum  distance  of  0.5m  must  be  maintained  between  the 

equipment and   combustible surface.

 The product must always be placed in a well ventilated area.

  Always make sure that the equipment is installed securely.

DO NOT stand close to the equipment and stare directly into the LED 

light  source.

Always  disconnect  the  power  supply  before  attempting  and 

maintenance.

  Always  make  sure  that  the  supporting  structure  is  solid  and  can

support the combined weight of the products.

 The earth wire must always be connected to the ground.

 Do not touch the power cables if your hands are wet.

ATTENTION

 This product left the place of manufacture in perfect condition.  In

order to maintain this condition and for safe operation, the user must

always follow the instructions and safety warnings described in this 

user manual.

 Avoid shaking or strong impacts to any part of the equipment.

 Make sure that all parts of the equipment are kept clean and free of 

dust.

 Always make sure that the power connections are connected correct 

and    secure.

 If there is any malfunction of the equipment, contact your distributor 

immediately.

 When transferring the product, it is advisable to use the original 

packaging in which the product left the factory.

 Shields, lenses or ultraviolet screens shall be changed if they have 

become damaged to such an extent that their effectiveness is 

impaired.

 The lamp (LED) shall be changed if it has become damaged or 

thermally deformed.

BLOCK1 RED

BLOCK1 GREEN

BLOCK1 BLUE

0

 255

0

0

 255

 255

0

 255

0

 255

0

 255

0

 255

0

0

 255

 255

1

2
3
4
5
6
7
8
9

BLOCK1

14
15

0

 255

0

0

 255

 255

0

 255

0

 255

0

 255

0

 255

0

0

 255

 255

0

 255

0

 255

1
2
3

6
7
8

11
12
13

BLOCK2

0

 255

0

 255

4
5

0

 255

0

 255

9
10

ARC 1

VALUE

FUNCTION

CHANNEL

BLOCK2 RED

BLOCK2 GREEN

BLOCK2 BLUE

BLOCK3 RED

BLOCK3 GREEN

BLOCK3 BLUE

BLOCK1 RED

BLOCK1 GREEN

BLOCK1 BLUE
BLOCK1 WHITE

BLOCK1 AMBER

BLOCK2 RED

BLOCK2 GREEN

BLOCK2 BLUE
BLOCK2 WHITE

BLOCK2 AMBER

BLOCK3 RED

BLOCK3 GREEN

BLOCK3 BLUE
BLOCK3 WHITE

BLOCK3 AMBER

1

3

4

0

 255

0

 255

0

 255

BLUE

RED

GREEN

VALUE

FUNCTION

CHANNEL

VALUE

FUNCTION

CHANNEL

Summary of Contents for Sion

Page 1: ...board Power supply Display PCB Fan Side cover LED driver PCB Fuse Supporting bracket No ITEM Power output socket white Power output socket blue 11 12 13 14 No ITEM 5 2 MAINTENANCE USER MANUAL Please...

Page 2: ...PRODUCT GENERAL 1 1 1 PRODUCT INTRODUCTION 1 1 2 PRODUCT FEATURES 1 1 3 TECHNICAL SPECIFICATIONS 2 1 4 PHOTOMETRIC DATA 3 1 5 SAFETY WARNING 4 PART 2 INSTALLATION 5 2 1 MOUNTING 5 2 2 POWER CONNECTIO...

Page 3: ...the slider is at the highest position 255 the intensity of the color is the maximum CH2 CH3 Ch4 Ch5 CH6can be combined together to create over 16 million colors COLOR MACROS AND WHITE BALANCE CH7 sele...

Page 4: ...9 x AMBER Weight LED Unit Cooling 990 x 156 x75mm 6Kg 100 240V 50 60Hz 87W Environment Temperature 20 40 Forced air convection 1 2 0 255 3 0 255 0 255 HSV HUE SATURATION VALUE CHANNEL VALUE FUNCTION...

Page 5: ...NNEL 1 2 3 0 1 2 3 2 4 6 8 10Distance m 1316 329 146 82 53 LUX 1 5 R 1 2 3 0 1 2 3 2 4 6 8 10Distance m 600 150 67 38 24 LUX A 1 5 1 2 3 0 1 2 3 2 4 6 8 10Distance m 3402 850 378 213 136 LUX RGBW 1 5...

Page 6: ...s described in this user manual Avoid shaking or strong impacts to any part of the equipment Make sure that all parts of the equipment are kept clean and free of dust Always make sure that the power c...

Page 7: ...with a clamp or other mounting bracket is recommended depending on the requirements of your application For overhead use always install two secure chains that can hold at least 10 times the weight of...

Page 8: ...y DMX address in the range from 001 to 512 may be used Example DMX Addr 1 DMX Addr 14 DMX Addr 27 0 255 AUTO SPEED 10 AUTO SPEED FOR Auto1 Auto10 Auto 6 Auto 7 Auto 8 Auto 9 111 120 Auto 10 121 130 13...

Page 9: ...l of the units in series using standard DMX512 signal cable or the IP65 rated cable provided Set the DMX512 address in the DMX menu It is possible to have the same DMX address or independent addresses...

Page 10: ...e of the current function scroll through the mainmenu or return tothe main menu MENU ENTER 3 1 BASIC 3 DISPLAY PANEL OPERATION 3 13 FAN SETTING FAN SETTING Enter the FAN SETTING to select the fan spee...

Page 11: ...4 5 7 8 9 DMX address 001 ID ON OFF ON COLOR OFF KEYLOCK OFF Parsonaliey TOUR Run mode DMX 10 Fan Auto 1 STATIC 000 ID address 001 6 DIMMER DIM4 EDIT 000 11 WHITE1 WHITE2 WHITE3 WHITE4 WHITE5 WHITE6 W...

Page 12: ...unit to the SLAVE units In order to activate the upload function the password must be entered Password is the same as the main access password When uploading the MASTER and SLAVE units will display Y...

Reviews: