background image

P. 10

Neo Proton IP 12 QA -

W-DMX WIRELESS SETTING

The Proton IP 12 QA features an onboard W-DMX 

receiver. By default, W-DMX is OFF. To activate:

•  Press the MENU button until the display shows 

Wireless Setting, Then press ENTER.

•  Press the UP/DOWN buttons to select Receive 

On, then press ENTER.

•  To reset the onboard W.DMX receiver, select 

Receive Reset, then press ENTER.

AUTO SHOW

If no DMX control signal is present at the DMX IN-

PUT, the unit independently runs through its show 

programme provided that the blackout mode is 

switched off:

•  Press the button MENU so many times until the 

display shows Auto Show, then press the button 

ENTER.

•  Press the button UP/DOWN to switch between 

the show (Auto 1-5). The unit will operate in 

show mode.

English version

Menu Structure (cont

'

d)

Wireless Setting

Receive On/Off

On

Default: Off

Off

Receive Reset

No

Default: No

Yes

Back Light

On

Default: On

10S
20S
30S

Key Lock

On

Password: Up Down Up 

Down Enter

Default: On

Off

Information

Fixture Hours

<9999H>

Version

<V1.0>

Reset Factory

No

Default: No

Yes

White Balance

Off

Default: Off

Manual

Red

<125-255>

Green

<125-255>

Blue

<125-255>

Amber

<125-255>

LED Frequency

600Hz

Default 1200Hz

1200Hz
2000Hz
4000Hz
6000Hz
25kHZ

Summary of Contents for PROTON IP 12 QA

Page 1: ...oton IP 12 QA USER MANUAL MANUAL DE USUARIO PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USE POR FAVOR LEA LAS INSTRUCCI NES ANTES DE USAR PROTON IP 12 QA OUTDOOR RGBA LED PROFESSIONAL WASHER WITH WI...

Page 2: ...eam angle 24 Field angle 38 Photometric data Luminous flux 912 Lux 5m 16 ft Effects Functions Quad color LED technology Smooth RGBA mix with no multi colored shadows Ideal for any setting thanks to am...

Page 3: ...o imflammable liquids wa ter or metal objects enter the fixture Do not dismantle or modify the fixture All work must always be carried out by qualified technical personnel Contact the nearest sales po...

Page 4: ...fully wipe the part dry For cleaning other housing parts use only a soft clean cloth Never use a liquid it might penetrate the unit and cause damage to it 4 TROUBLESHOOTING Problems Possible causes Ch...

Page 5: ...OUT 5 pin IP65 XLR 1 ground 2 DMX 3 DMX 4 N C 5 N C 5 CONTROL PANEL with display and 4 button used to access the control panel functions and manage them 6 SAFETY ANCHOR POINT to attach safety cable 7...

Page 6: ...stallation always comply scrupulously with all the regulations particularly regarding safety currently in force in the country in which the fixture s being used Install the projector at a suitable loc...

Page 7: ...P 7 Neo Proton IP 12 QA English version Dimensions 195 238 239 201 5...

Page 8: ...nit to a socket which can be switched on and off via a light switch Basic Access control panel functions using the four panel buttons located directly undernearth the black OLED display English versio...

Page 9: ...BA RB GBA RG RGBA RGB Color Temperature 3000K Default 3000K 4000K 5000K 6000K 7000K 8000K 9000K 10000K Manual Color Mixer Red 0 255 Default RGBA 255 Green 0 255 Blue 0 255 Amber 0 255 Auto Show Auto 1...

Page 10: ...that the blackout mode is switched off Press the button MENU so many times until the display shows Auto Show then press the button ENTER Press the button UP DOWN to switch between the show Auto 1 5 Th...

Page 11: ...it must be the fist unit in line other units will work as slave with the same effect Press the button MENU so many times until the display shows Master Slave and press the button ENTER Press UP DOWN t...

Page 12: ...oller Example of DMX configuration in 4 channel mode DMX address 41 DMX address 45 Beam Angle 24 Proyect Distance m 1m 16256 lux 1806 lux 3m Luminance lux Full Photometrics channel If e g address 33 o...

Page 13: ...tput of the first unit Connect the DMX output to the DMX input to the following unit Connect again the output to the input of the following unit until all the units are connected in chain When the sig...

Page 14: ...G 0 B 100 R 100 G 0 B 100 0 R 100 G 0 100 B 0 100 R 100 0 G 100 0 B 100 R 100 G 100 B 100 A 100 Color 1 Color 2 Color 3 Color 4 Color 5 Color 6 Color 7 Color 8 Color 9 Color 10 Color 11 000 010 011 0...

Page 15: ...Auto Program 3 Auto Program 4 Auto Program 5 000 010 011 060 061 110 111 160 161 210 211 255 10 Auto Speed Slow to fast 000 255 11 Dimmer Speed Preset dimmer speed from display menu Dimmer speed mode...

Page 16: ...button ENTER to confirm Using the button UP DOWN to select Fixture Hours then press the button ENTER to confirm Then the display will show the working hours Press MENU to return ro main menu VERSION...

Page 17: ...promedio 50 000 horas ngulo de haz 24 ngulo de campo 38 Datos fotom tricos Flujo lum nico 912 Lux 5m 16 pies Efectos y funciones Tecnolog a LED de cuatro colores Mezcla RGBA suave sin sombras multico...

Page 18: ...C Evite que l quidos inflamables objetos de metal o agua entren en contacto con el equipo No desarme o modifique el equipo El mantenimiento o reparaci n del equipo deben ser realizados por personal ca...

Page 19: ...con cuidado Para otras partes del equipo solo emplee un pa o suave y limpio No utilice ning n tipo de l quidos ya que podr an filtrarse en el equipo y causar da os severos 4 RESOLUCI N DE PROBLEMAS E...

Page 20: ...MX XLR 5 IP65 1 Tierra 2 DMX 3 DMX 4 Sin funci n 5 Sin funci n 5 PANEL DE CONTROL con pantalla y cuatro botones que brindan acceso a las funciones disponibles 6 ORIFICIO PARA EL CABLE DE SEGURIDAD 7 E...

Page 21: ...equipo Aseg rese de cumplir con todas las regulaciones locales especialmente aquellas referidas a la segu ridad al momento de realizar el montaje Instale el proyector en un lugar apropiado me diante l...

Page 22: ...P 22 Neo Proton IP 12 QA Dimensiones Versi n Espa ol 195 238 239 201 5...

Page 23: ...del suministro el ctrico Se recomienda conectar el equipo a una red con interruptor para agilizar el encendido y apagado Panel de control Acceda a las funciones del panel de control a trav s de las cu...

Page 24: ...3000K Temperatura de color 3000K 4000K 5000K 6000K 7000K 8000K 9000K 10000K Manual Color Mixer Red 0 255 Mezcla de color manual RGBW 255 Green 0 255 Blue 0 255 Amber 0 255 Auto Show Auto 1 1 100 Progr...

Page 25: ...receptor inal mbrico selec cione Receive Reset y luego presione ENTER PROGRAMAS AUTOM TICOS En caso de no haber se al DMX utilice uno de los cinco programas incorporados siempre que el modo blackout...

Page 26: ...este modo podr enlazar varios equipos en serie sin necesidad de un controlador La primera unidad funcionar como equipo maestro y el resto como esclavos Presione la tecla MENU hasta visualizar Master S...

Page 27: ...o 33 en el PROTON IP 12 QA El res to de las funciones del panel de efectos se asignar autom ticamente a las direcciones subsiguientes A continuaci n un cuadro que ilustra el ejemplo de la direcci n de...

Page 28: ...el controlador a la salida DMX de la primera unidad Conecte la salida DMX a la entrada DMX de la siguiente unidad Reitere este paso hasta conectar todas las unidades deseadas Cuando el cable DMX debe...

Page 29: ...100 R 0 100 G 0 B 100 R 100 G 0 B 100 0 R 100 G 0 100 B 0 100 R 100 0 G 100 0 B 100 R 100 G 100 B 100 A 100 Color 1 Color 2 Color 3 Color 4 Color 5 Color 6 Color 7 Color 8 Color 9 Color 10 Color 11 0...

Page 30: ...m tico 3 Programa autom tico 4 Programa autom tico 5 000 010 011 060 061 110 111 160 161 210 211 255 10 Velocidad autom tica Velocidad creciente 000 255 11 Velocidad de dimmer Velocidadpreestablecidad...

Page 31: ...DOWN para seleccionar entre Fixture Hours Confirme la selecci n con la tecla ENTER La pantalla indicar el total de horas de funciona miento del Proton IP 12 QA VERSI N Presione la tecla MENU hasta vi...

Page 32: ...P 32 Neo Proton IP 12 QA neo amproweb com...