Connection/Configuration Diagram
7
*JP4 – Bypass Safety Switch. Not to be installed during normal use.
All other Jumpers are reserved for factory use only
JUMPER OPERATION:
Function
JP1
JP2
JP3
Energizer Operation
Gate Alarm
out
in
out Switched Input delayed for 4 minutes with
energizer On only
Gate Alarm
in out out Switched Input delayed for 1 minute with
energizer On only
Panic Alarm
out out out Switched Input instantaneous (panic alarm)
with energizer On or Off
High/Low
Voltage Mode
in
in
out Switched Input toggles the energizer between
High Voltage and Low Voltage mode
Remote On/Off out out
in Switched Input acts as remote On\Off switch
Remote On/Off
indication and
Gate alarm
in out
in Strobe indicates fence is On or Off, Switched
Input delayed for 4 minutes with energizer On
only
Not yet available out
in
in Service Alarm disabled, Switch Input delayed
for 4 minutes with energizer On only
in
in
in Reserved for factory use