background image

 

 
 

 

INTRODUCTION 

 

The energizer should ideally be operated by means of a remote keypad. This 
enables the user to have access to many energizer features and offers the 

greatest security. It can, however, be operated by means of a Nemtek tab or 
a remote on/off switch. 

 

OPERATION WITHOUT A KEYPAD 

 

Turning the energizer On/Off:

  Unless the feature has been disabled by 

the installer, the energizer can be turned On or Off by holding the Nemtek 

plastic tab over the corresponding logo on the fascia of the unit. Remove the 
tab on noticing the energizer turning On or Off. 
 

After an alarm occurs:  

Switch the unit off with the Nemtek tab or remote 

key-switch. This will silence the siren ( if it has not already timed-out), 
internal beeper and will switch the strobe off. One of the alarm lights will be 

flashing or remain lit to indicate the source of the alarm. A permanently lit 
indicator notifies the user that the fault no longer exist. In the latter case 

simply turning the energizer On again will clear the memory condition. A 
flashing alarm light illustrates that the fault condition persist. In this case 
rectify the condition which caused the alarm. To reset and clear the memory 

condition turn the energizer On and Off and On again. Only if the alarm 
condition is resolved will the energizer operate without alarm activation.      

 

OPERATION WITH A KEYPAD 

 

The energizer may be operated via a remote keypad. In this case the Nemtek 

tab becomes optional. ( Installer programmable). 
 

In order to provide different access levels to the energizer and its functions 
different types of user are defined.  
 

A master user has full control of the energizer and may bypass different alarm 
functions. The master user may change the pin identification number for all 
the users. There is only one master user with a default PIN of 1234, user #0. 

 
There are three normal users and three reset users.  

 

A normal user may turn the energizer On/Off and reset alarm conditions but 
not change the functionality of the energizer. User #1,#2 and #3. For  

 

 

MERLIN STEALTH

  

M113S     

 Introduction 

 

PDF created with pdfFactory trial version 

www.pdffactory.com

Summary of Contents for MERLIN STEALTH M113S

Page 1: ...M113S Users Manual Revision 1 0 Date 29 January 2007 GROUP OF COMPANIES MERLIN STEALTH M113S Electric Fence Energizer PDF created with pdfFactory trial version www pdffactory com ...

Page 2: ...KEYPAD 5 OPERATION WITH A KEYPAD 5 USING YOUR KEYPAD KEYPAD 6 10 FENCE INDICATOR LIGHTS 11 WHAT THE ENERGIZER LIGHTS INDICATE 12 WHAT THE KEYPAD LIGHTS INDICATE 13 DOCUMENT REVISION HISTORY 14 No user serviceable parts inside the energizer PDF created with pdfFactory trial version www pdffactory com ...

Page 3: ...documentation and energizer features can be viewed on our website at www nemtek com The M113S Energizer has patented energy control and safety features Refer any questions and special requirements to suitably trained installers Electric fencing can be lethal Avoid head contact with the fence Get the installer to explain the options of current limiting resistors the enhanced safety features of the ...

Page 4: ...Warehouse Unit 4 Meadowdale Park Cnr Herman Dick Kemp Roads Meadowdale Edenvale Gauteng South Africa The buyer shall pay all shipping and other charges for the return of the product to Nemtek or Nemtek Security Warehouse L I M I T A T I O N O F G U A R A N T E E The guarantee does NOT apply to defects resulting from acts of GOD modifications made by the buyer or any third party misuse neglect abus...

Page 5: ...ly turning the energizer On again will clear the memory condition A flashing alarm light illustrates that the fault condition persist In this case rectify the condition which caused the alarm To reset and clear the memory condition turn the energizer On and Off and On again Only if the alarm condition is resolved will the energizer operate without alarm activation OPERATION WITH A KEYPAD The energ...

Page 6: ...hed off Use the Gate Bypass function if these inputs are to be ignored USING YOUR KEYPAD SWITCH THE FENCE ON OFF Master Normal User To switch the fence On or Off enter your four digit PIN followed by the key If the red ON light is lit or flashing the fence is energized Don t pause for more than 5 seconds while entering the digits or the control panel will reject your PIN number If you make a mista...

Page 7: ...re in the fence vicinity BYPASS THE FENCE ALARM Enter your PIN master only and press the key enter the digit 1 then press the key The FENCE ALARM light will start flashing slowly to confirm the fence alarm is bypassed To cancel the bypass repeat the same sequence of keys BYPASS THE SIREN AND STROBE LIGHT SILENT ALARM Enter your PIN master only and press the key enter the digit 4 then press the key...

Page 8: ...tes MAKE THE GATE ALARM DELAYED Gate 1 Enter your PIN master only and press the key enter the digit 2 followed by the digit 4 followed by the digit 1 then press the key The default gate delay is 30 seconds MAKE THE GATE ALARM DELAYED Gate 2 Enter your PIN master only and press the key enter the digit 2 followed by the digit 4 followed by the digit 2 then press the key The default gate delay is 30 ...

Page 9: ... ON Gate2 Enter your PIN master only and the key enter the digit 2 enter the digit 8 enter the digit 3 then press the key If the chime is on the keypad will beep three times if the gate opens and twice if it closes TURN THE GATE CHIME OFF Gate2 Enter your PIN master only and the key enter the digit 2 enter the digit 8 enter the digit 4 then press the key No audible indication of gate opening or cl...

Page 10: ...NGING A USER PIN Enter your master PIN press the key enter the digit 0 then press the key Enter the user number 0 6 and push the key User number 0 is the master PIN that has system configuration rights i e bypass of alarm conditions etc Enter that user s new PIN and press the key Enter the new PIN again and press the key If the new PIN is accepted the control panel will beep four times If you make...

Page 11: ...OD as the effectiveness of the fence is maintained Should the fence loading be such that the fence voltage is insufficient to be a deterrent then the ALARM indicator will remain lit or have a fast flash and the alarm outputs if enabled will activate FENCE1 Fence voltage acceptable Fence voltage questionable Inspect fence and do maintenance If lit permanently the fence dropped below acceptable volt...

Page 12: ...roblem on fence FENCE BYPASS SLOW FLASH Fence alarm switched off GATE OPEN FAST FLASH Gate is open GATE BYPASS SLOW FLASH Gate alarm switched off GATE IMMEDIATE 1 FLASH EVERY 5 SECONDS Appropriate gate input is in immediate mode SILENT ALARM 1 SHORT FLASH EVERY 5 SECONDS Siren or strobe light not activated by alarm GATE2 CONTROLS FENCE VOLTAGE Gate2 LONG FLASH EVERY 5 SECONDS Gate 2 closed fence i...

Page 13: ...BYPASS SLOW FLASH Fence alarm switched off GATE OPEN FAST FLASH Gate is open GATE BYPASS SLOW FLASH Gate alarm switched off GATE IMMEDIATE 1 FLASH EVERY 5 SECONDS Appropriate gate input is in immediate mode SILENT ALARM 1 SHORT FLASH EVERY 5 SECONDS Siren or strobe light not activated by alarm GATE2 CONTROLS FENCE VOLTAGE Gate2 LONG FLASH EVERY 5 SECONDS Gate 2 closed fence in low voltage mode Gat...

Page 14: ...14 MERLIN STEALTH M113S Document Revision History DOCUMENT REVISION HISTORY Revision 1 0 29 January 2007 End of document PDF created with pdfFactory trial version www pdffactory com ...

Reviews: