13
MERLIN 4
Installer Options
The keypad will beep twice to indicate that the setting was accepted.
Example: To change the Fence Voltage to 6 kV, enter
0 5 3 #
The default Fence Voltage is
7 kV
.
The energizer will only use the High Power Fence Voltage
parameter when mains is present.
The energizer has a
unique algorithm for extending battery life during mains failure
conditions and automatically controls the fence voltage.
LOW POWER FENCE VOLTAGE
The open circuit low power fence voltage can be changed by pressing the
0
key, followed by
the
6
key. Select the desired voltage from the table and press the corresponding number
from
0
to
4
followed by the
#
key. The keypad will beep twice to indicate that the new
setting was accepted.
Example: To change the Low Power Fence Voltage to 1900 Volts,
enter
0 6 4 #
The default Low Power Fence Voltage is
1700 Volts
.
STROBE LIGHT FUNCTION
The strobe light output can be changed by pressing the 1 key followed by the 0 key. Select
the desired function from the table and press the corresponding number from 0 to 1 followed
by the # key. The keypad will beep twice to indicate that the new setting was accepted.
Example: To change the Strobe Light Function so that the
strobe
light switches on whenever the fence is on, enter 1 0 1 #
The default Strobe Light Function is option 0. The strobe light
switches on when the alarm is activated.
MAGNETIC SWITCH ENABLE
The magnetic On/Off switch (under the facia of the energizer) can be enabled by pressing the
1
key, followed by the
0
key. Select the desired state from the table and press the
corresponding number from
2
to
3
followed by the
#
key. The keypad will beep twice to
indicate that the new setting was accepted.
Example: To enable the magnetic On/Off switch,
enter
1 0 3 #
By default the Magnetic switch is
disabled
.
0
3.0 kV
1
4.0 kV
2
5.0 kV
3
6.0 kV
4
7.0 kV
0
1500 V
1
1600 V
2
1700 V
3
1800 V
4
1900 V
0
Strobe light = Alarm
1
Strobe light = fence ON
2
Magnetic switch disabled
3
Magnetic switch enabled
6
0
#
0
1
#
0
1
#