All keypad codes must end with the 

#

 key to enter the code sequence. 

 
If you pause for more than five seconds between key presses, the keypad will produce a 
fast beeping sequence and all earlier keys will be deleted. 
 
A correctly entered sequence will be acknowledged with two beeps.

 

 

Activating and deactivating the energizer   _  _  _  _  # 

 
The energizer can be activated or deactivated by entering the four digit master PIN 
(default master PIN is 1234). 
 
If the fence is off, the 

O

 symbol under the FENCE label on the keypad will be lit and on the 

energizer display the 

O

 symbol linked to the FENCE MODE label will be shown. 

 
If the fence is on, one of the 

GOOD

CHECK

 or 

BAD

 indicators on the left of the keypad 

will be lit and the energizer display will show 

GOOD

CHECK

 or 

BAD

, depending on the 

fence condition and fence voltage. 
 

Acknowledging and silencing an alarm condition   _  _  _  _  # 

 
Enter the reset PIN (default reset PIN is 5555). The siren will be silenced if not yet timed 
out, the internal beeper will stop sounding and the strobe will be deactivated. One of the 
alarm      , alarm history       or event        symbols will indicate the source of the alarm. 
The above can also be achieved through entering the master PIN, however the energizer 
operating state will be toggled at the same time. 
 

Clearing an alarm or event from memory   _  _  _  _  # 

 
An alarm       symbol indicates that the condition persists and will have to first be 
corrected. An alarm history       symbol indicates the fault no longer exists and simply 
entering the reset PIN will clear the memory condition. Only if the alarm condition is 
resolved will the energizer operate without further alarm activation. 
 
The above can also be achieved through turning the energizer 

Off

 and 

On

 again using the 

master PIN. 

Using your keypad 

11 

MASTER PIN 

MASTER PIN 

MASTER PIN 

Summary of Contents for druid LCD

Page 1: ...Druid LCD Electric Fence Energizer User Manual...

Page 2: ...K Group outlets 5 Foreword 6 Symbol interpretation 7 Symbol to label link 8 Operation without a keypad 9 Operation with a keypad 10 Using your keypad 11 Keypad zone focus 16 IEC Safety Information 17...

Page 3: ...eneral information are available on our web site at http www nemtek com COMPANY PROFILE The NEMTEK Group of Companies manufacture and distribute intelligent electronic agricultural fencing systems sec...

Page 4: ...Group outlets The buyer shall pay all shipping and other charges for the return of the product to NEMTEK or NEMTEK Security Warehouse LIMITATION OF GUARANTEE The guarantee does not apply to defects r...

Page 5: ...Africa CAPE TOWN Tel 27 0 21 386 3742 27B Concord Crescent Airport City Fax 27 0 21 386 5573 Cape Town South Africa NELSPRUIT Tel 27 0 13 752 2187 Waterval Ave Riverside Industrial Fax 27 0 13 752 21...

Page 6: ...gizer incorporates an advanced and patented fence voltage regulation arc detection and avoidance system What this means is that the fence energy is maintained at a higher level than would normally be...

Page 7: ...ence voltage is below CHECK threshold Fence voltage is below ALARM threshold Fence is off Fence condition indication from 0 to 9 higher values are better Fence condition and voltage notes Fence voltag...

Page 8: ...he display under the third linking line the symbol is linked to the FENCE MODE label and is interpreted to mean that the fence is off If however the O symbol is positioned on the right of the display...

Page 9: ...he unit An initial short beep will be heard as the tab is detected but keep holding the tab in place until a second longer beep is heard The siren will be silenced if not yet timed out the internal be...

Page 10: ...user is referred to as user number 2 or PIN 2 Most energizer user functions are accessed using the master PIN followed by a key a two key sequence and then completed with the enter key The two key seq...

Page 11: ...tion and fence voltage Acknowledging and silencing an alarm condition _ _ _ _ Enter the reset PIN default reset PIN is 5555 The siren will be silenced if not yet timed out the internal beeper will sto...

Page 12: ...ence low power voltage is an installer programmable voltage If the fence is in low power the symbol under the FENCE label on the keypad will be lit and on the energizer display the symbol linked to th...

Page 13: ...gate is opened without waiting for the gate delay time to expire If the gate alarm is instant the i symbol under the GATE label on the keypad will be lit and on the energizer display the i symbol lin...

Page 14: ...PIN is required CHANGING A USER PIN _ _ _ _ 0 start change user PIN _ _ _ _ enter new PIN _ _ _ _ confirm new PIN To change a user PIN requires three key code sequences in succession Depending on whic...

Page 15: ...the harder the energizer has to work to maintain the voltage on the fence This is reflected as an increase in stored energy and energizer capacity used The energizer cannot work harder than 100 effort...

Page 16: ...rolling both zone 3 and zone 4 To change the keypads focus to all zones so that keypad activity is directed to both energizers and so that all four zones respond type 0 into the keypad While in global...

Page 17: ...instruction concerning use of the appliance by a person responsible for their safety Electric fencing can be lethal Avoid head contact with the fence Ask the installer to explain the options of curren...

Reviews: