Page 1: ...Druid LCD 20 Fence Monitor Installer Manual ...
Page 2: ...replacement 8 Connections 9 Fence wiring diagrams 10 4 zone installation 12 Network cards and NEMTEK Connect 13 Large network 14 Solar installation 15 Detailed service indicators fuses 16 Installation notes 17 Programmable options 18 Programmable options summary 29 Document revision history 30 Table of Contents 2 ...
Page 3: ...able for connection to mains power AC 100V 240V 50 60Hz The batteries to be used are rechargeable lead acid batteries Non rechargeable batteries must not be used The lead acid batteries require venting and it is imperative that the unit be situated in a well ventilated area A new fully charged battery will typically provide in excess of 24 hours backup DISCLAIMER NEMTEK Holdings Pty Ltd or any of ...
Page 4: ...EK Group outlets The buyer shall pay all shipping and other charges for the return of the product to NEMTEK or NEMTEK Security Warehouse LIMITATION OF GUARANTEE The guarantee does not apply to defects resulting from acts of God modifications made by the buyer or any third party misuse neglect abuse accident and mishandling EXCLUSIVE REMEDIES The remedies provided herein are NEMTEK s sole liability...
Page 5: ... 0 41 581 4130 Unit 4 51 Leadwood Crescent Fairview Or Tel 27 0 41 581 4064 Port Elizabeth South Africa PINETOWN Tel 27 0 31 701 2125 19 Henwood Road Pintetown KwaZulu Natal Or Tel 27 0 31 701 3131 South Africa NELSPRUIT Tel 27 0 13 752 2187 44 Rapid Road Riverside Industrial Park Nelspruit South Africa BLOEMFONTEIN Tel 27 0 51 004 0490 Plot 42 Gemsbok Street Unit 12 Quaggafontein Bloemfontein Sou...
Page 6: ...er unit can communicate with keypads and other devices present on the keypad bus A set of jumpers positioned above each of the three unit s relays allow the relay contacts to be configured as either wet providing 12V nominal power or dry potential free contacts The unit s display will light with a blue OFF green all is OK yellow alarm in history or other medium priority event or red active alarm c...
Page 7: ...ap slightly more than the thickness of the casing between screw heads and wall Position the casing so that the screws go through the slots provided then drop it into position Tighten the top 2 screws to secure the casing The bottom two screws will slot into the casing for stability they don t need to be tightened STEP 5 Insert battery with the negative terminal to the top STEP 6 Place the battery ...
Page 8: ...g plate unplugging it from the connectors beneath it There are four spade connectors beneath the PC Board in the middle of the board STEP 5 To replace the PC Board align the four spade connectors in the middle of the PC Board using the guide tabs and gently press the PCB down into place STEP 6 Re insert and tighten the five screws STEP 7 Reconnect the seven connectors to the PC Board STEP 8 Reconn...
Page 9: ...it Gate Switch Normally closed External On Off Switch for Zone 1 External On Off Switch for Zone 2 Panic Switch Normally closed A maximum of two NEMTEK Druid 4 Zone keypads two expansion cards and 100m of comms cable can be connected A total of two units can be linked together See Creating a 4 zone installation later on in this manual ...
Page 10: ...to the main earth spike and not directly to the unit Install the main earth spikes close to the unit Earth wire connection with no earth loop monitoring Fence 1 Fence 2 Install the main earth spikes close to the unit Fence 1 Fence 2 The Druid LCD D20 can be connected to a standard electric fence installation as a low voltage substitute for an electric fence energizer The installation and erection ...
Page 11: ... All earth spikes are connected to one wire of the fence only and this one wire is connected to the rest of the fence at the main earth spikes Earth wire connection with earth loop monitoring preferred Install the main earth spikes close to the unit Earth wire connection with no earth loop monitoring Fence wiring diagrams 11 Note Diagrams illustrate connections of only 1 zone for simplicity Both z...
Page 12: ...lave to prevent the energizer from generating a synchronisation loss fault Master will show as zones 1 2 on the keypad Slave will show as zones 3 4 on the keypad Lastly the master needs to be informed whether a slave unit is connected creating a four zone system or if it is a master only two zone system This is to allow a communication failure service alarm to be generated should the slave unit no...
Page 13: ... card or a NEMTEK Connect card can be connected These cards enable networking or remote access and control of the unit Visit the NEMTEK website www nemtek co za for the latest details on the smartphone app and networking options available to you Network cards and NEMTEK Connect 13 ...
Page 14: ...will need to have a unique address in the range 1 32 The unit s large network address is set using installer code 51 detailed on page 28 of this manual Please read the energizer synchronisation requirements in the Druid LCD 2x Installer Manual if more than one energizer is connected to the network Large network 14 ...
Page 15: ... with an output power rating of at least 50W The unit must be configured for solar installation by entering the keycode 4071 refer to keycode description later in this manual Note If the Druid LCD 20 has a Nemlink Ethernet card installed a separate earth spike not connected to the fence ground must be installed at least 2m away from the fence earth 15 ...
Page 16: ...condition spanner symbol and the service condition is still present further information will be displayed indicating the cause of the service condition as listed below A Aux fuse blown B Battery fuse blown battery fault or not connected N Slave unit communication failure FUSE DESCRIPTION AND FAULT SYMPTOMS All fuses are of the fast blow type The Main fuse has a 4A rating while the Battery and Aux ...
Page 17: ... with any fence high voltage wires You may connect a total of two keypads one expansion card and one slave unit to a DRUID LCD 20 set to master Use HT high voltage wire between the fence and the DRUID LCD 20 including the earth wire Never run these wires in the same conduit or through the same hole as the low voltage wiring Always use ferrules or line clamps to connect two fence wires together Avo...
Page 18: ...the exit code CHANGE INSTALLER PIN 0 0 _ _ _ _ _ _ Changes the factory default six digit installer PIN to a new six digit PIN SIREN ON TIME 0 1 _ _ Sets the siren on active time m minutes s x10 seconds Programmable range is 0101 10s to 0141 4m 10s Factory default value is 0120 2m 0s Siren active time is the amount of time that the siren will sound before automatically turning off if not reset by t...
Page 19: ...quired by law to prevent an alarm from sounding indefinitely while the owner is not home to correct the alarm condition RELAYS ACTIVE OPEN 0 0 6 _ Set the active state of all three relays on the unit s PCB 0 relay closed when active or 1 relay open when active Factory default value is 0060 relay normally open closed on activation Typically used when the unit is connected to an alarm system requiri...
Page 20: ...ion or 2 service alarm Factory default value is 0030 gate alarm The siren relay can be assigned to be active when a gate alarm occurs 0 or to indicate when the unit is on 1 or to activate on service alarm 2 Both zone 1 and zone 2 need to be active for the relay to indicate that the unit is on STROBE RELAY FUNCTION SENSOR ALARM MODE 0 0 7 _ Selects between gate alarm unit on off indication or servi...
Page 21: ...ne 2 is in alarm condition The siren relay by factory default will be active only as long as the gate is in alarm condition If however the siren relay function has been altered using the SIREN RELAY FUNCTION the siren relay will be active as long as both fence zone 1 and zone 2 are active Additional status information can be obtained such as zone active zone check condition mains fail service and ...
Page 22: ...ose The user can enable a gate chime notification using the GATE CHIME user code as detailed in the Druid LCD User Manual This GATE CHIME ON CLOSE installer code additionally enables chiming on closure of the gate as well INPUT TOGGLE SELECT 1 1 1 _ Selects toggling or direct on off control of the fence monitoring 0 direct control or 1 toggle control Factory default value is 1110 direct control Wi...
Page 23: ...sing KEYPAD ZONE FOCUS FENCE CONDITION CHECK LEVEL 2 0 1 _ Sets the value at which the CHECK message will be displayed should the fence condition indicator reduce to or below this set value check level between 4 and 7 Programmable range is 2014 4 poor to 2017 7 fair Factory default value is 2014 4 poor Can be directed to a specific zone using KEYPAD ZONE FOCUS FENCE CONDITION ALARM LEVEL 2 7 0 _ S...
Page 24: ...el between 0 and 4 Programmable range is 2303 3 bad to 2340 40 good Factory default value is 2319 19 fair The alarm level must always be set below the check level for the new setting to be accepted Can be directed to a specific zone using KEYPAD ZONE FOCUS FENCE ALARM DELAY 2 5 _ _ Sets the delay time for the unit to alarm after a violating fence condition has occured number of seconds before alar...
Page 25: ...isables alarming during a service condition 0 disabled or 1 enabled Factory default value is 4041 enabled DISPLAY INSTALLER TEL NUMBER 4 0 5 _ Enables or disables the displaying of the installers telephone number during a service condition 0 disabled or 1 enabled Factory default value is 4050 disabled When enabling this function don t forget to set a new telephone number using the 10 digit new tel...
Page 26: ... communication is present for longer than 60 seconds on the data port The deactivation only happens once after a communication loss and the function is reset on each successful communication restoration Therefore after a communication loss deactivation event if the unit is manually activated again using the keypad mag switch or digital input it will then not deactivate again while communication re...
Page 27: ...ion Configuration 1 Relay 1 Expansion card communication timeout Relay 6 Zone 1 in Check Relay 2 Zone 1 On Off status Relay 7 Zone 2 in Check Relay 3 Zone 2 On Off status Relay 8 Mains fail battery low service tamper Relay 4 No Function Relay 9 Zone 1 in alarm Relay 5 No Function Relay10 Zone 2 in alarm Input 1 Zone 1 On Off control Input 3 No Function Input 2 Zone 2 On Off control Input 4 No Func...
Page 28: ...nit to be found on a new network but for the network to operate correctly the unit must finally be assigned an address in the range of 1 to 32 SET INSTALLER TEL NUMBER _ _ _ _ _ _ _ _ _ _ Sets the telephone number to be displayed during a service condition The telephone number must be exactly 10 digits long and the displaying of this number must be enabled as the factory default is to not display ...
Page 29: ...UNCTION 1 1 2 Z2 ON OFF INPUT FUNCTION 1 1 3 FENCE STATE AT POWER ON 2 0 2 FENCE CONDITION CHECK LEVEL 2 0 1 FENCE CONDITION ALARM LEVEL 2 7 0 FENCE RETURN VOLTAGE CHECK LEVEL 2 2 FENCE RETURN VOLTAGE ALARM LEVEL 2 3 FENCE ALARM DELAY 2 5 m s BUZZER MUTE 4 0 0 MAGNETIC SWITCH 4 0 1 TAMPER ALARM 4 0 3 SERVICE ALARM 4 0 4 DISPLAY INSTALLER TEL NUMBER 4 0 5 SHOW KEY PRESSES ON LCD 4 0 6 SOLAR POWERED...
Page 30: ...12 January 2021 First release Rev 1 1 20 January 2022 Key codes for Fence Return Voltage Level added Rev 1 2 10 May 2022 Nemtek Group Outlets updated Rev 1 2 10 May 2022 Front page heading changed Revision History ...