background image

6

3. WIRING AND INSTALLATION PROCEDURES

Your Wind Turbine is shipped partially assembled. Please completely read
all procedures before beginning installation.   NOTE: Do not install the blade/hub
until the turbine is mounted on the tower

SHOOTPOWER

4mm hex key wrench (included)
5mm hex key wrench (included)
8mm hex key wrench (included)

Power cables (not included):
#12 AWG (American Wire Gage) stranded.
Batteries (not included)
Steel Pipe: 1 1/2", Schedule 40 steel pipe (Actual OD 1.875 inches, 48mm) (not
included)
Torque wrench with 4mm, 5mm, and 8mm hex drives (not included)
Soldering iron or propane torch (not included)
Rosin core solder (not included)
Electrical tape or 1/4” (6-7mm) heat shrink (not included)
Wire strippers (not included)
Wire crimpers (not included)

NOTE: Do not connect to the battery.

Precheck

Spin rotor shaft slowly with your fingers
while at the same time connecting and 
disconnecting the DC OUTPUT's positive
and negative wires. With the wires
connected, the rotor shaft should become
more difficult to rotate. With the wires
disconnected, it should spin freely.

Every time connect the DC 
OUTPUT's wires (RED= Positive, 
BLACK = Negative)
directly to the set of posts of the 
battery, the controller LED  will 
lighten to indicate that the 
controller is running properly.

CAUTION: DO NOT CONNECT WIND 
GENERATOR POSITIVE TO BATTERY
NEGATIVE AND CHARGE CONTROLLER 
NEGATIVE TO BATTERY POSITIVE FOR
EVEN A SECOND, OR ELSE WILL DAMAGE THE WIND GENERATOR'S
CONTROLLER AND VOID YOUR WARRANTY.

Red wire

Red wire

black wire

Summary of Contents for FSH400

Page 1: ...Instruction Manual FSH400 Wind Generator Serial number...

Page 2: ...prior notice Therefore check the website for updates as necessary The 400 Watt Wind Turbine like other sources of electrical power must be installed following the guidelines established by state and l...

Page 3: ...em wiring diagrams 4 LOCATION SELECTION 5 TOWER 6 1 SINGLE WIND GENERATOR 6 2CONTROLLER WIRING 6 3 INSTALLATION OPERATION 6 4 ATTACHING TO POLE 6 5 STEP BY STEP INSTRUCTION 7 WARRANTY POLICY 7 1 ELEVA...

Page 4: ...rical dangers The internal electronics of the Wind Turbine prevents open circuit voltages from rising above 20 volts for 12 volt systems Please note that the inherent personal dangers from electrical...

Page 5: ...ine yaw and the turbine rotor will require approximately 60 100 hours of operation in normal wind speeds approximately 18 20 mph 8 9 m s before they are running at peak efficiency During this break in...

Page 6: ...or 1 4 6 7mm heat shrink not included Wire strippers not included Wire crimpers not included NOTE Do not connect to the battery Precheck Spin rotor shaft slowly with your fingers while at the same ti...

Page 7: ...bulence Smooth laminar airflow 2H 20H Turbulent airflow 2H H Turbulent airflow created by obstructions Ad P Gipe 93 Therefore as a general rule the Wind Generator should be mounted twice as high as an...

Page 8: ...cost and effort of the installation This Wind Generator is designed to use steel pipe 1 875 inch 48mm outside diameter equivalent to 1 inch SCH 40 pipe which can be used in some tower applications If...

Page 9: ...op Rotor rotating at low spin or stop Rotor rotating at low spin or stop rotation and stop suddenly Rotor rotating at 500 1400rpm Battery fully charged voltage exceeds14 2V Over speed Rotor rotating o...

Page 10: ...negative and negative to positive or else will damage the controller Red is for positive Black is for negative Note 3 red wires from turbine can be placed in any order to controller AC input terminal...

Page 11: ...CAREFULLY NOTE DO NOT install the blade assembly until the body is mounted on the tower CAUTION ALL BATTERIES MUST DISCONNECTED THROUGHOUT THE INSTALLATION PROCESS CAUTION DO NOT INSTALL THE WIND GEN...

Page 12: ...d generator by the pipe 3 Connect the Wind Generator to the wires and insulate the connections using either heat shrink tubing or a quality electrical tape 4 Once the yaw shaft is on the tower firmly...

Page 13: ...blades assembly onto the rotor shaft and place the nut on the shaft DO NOT press the rotor shaft into the body Caution over torque will damage the blades and wind generator M16 NUT 8 Insert the 8mm he...

Page 14: ...egative wire of your system should be connected to a ground This is usually done by connecting a wire from the negative battery terminal to a nearby ground rod Wires with the same ratings as the posit...

Page 15: ...7 000 8 000ft 8 000 9 000ft 9 000 10 000ft 150 300m 300 600m 600 900m 900 1 200m 1 200 1 500m 1 500 1 800m 1 800 2 100m 2 100 2 400m 2 400 2 700m 2 700 3 000m 97 94 91 88 85 82 79 76 73 70 7 1 ELEVATI...

Page 16: ...FSH 8 SPECIFICATIONS 839290007068 FSH400 Marine grade 400 Watt Wind turbine DC12V or DC24V...