Trouble - Shooting 

12 

Compression of lugs cannot be completed:

A. Applied cables or terminals are over-specification.

B. Operation instructions were not followed. The product or dies have been

already damaged.

C. Interna! leakage: Contact our service representatives.

■ Dies can not be set in place or can not be removed:

A. Deformed tool head or dies. Contact our service representatives.

B. Clean the grooves on the tool head to remove impediments.

C. Clean the die seats on the tool head to remove impediments.

■ The piston is stuck or is unable to retract after operation:

The piston may have been deformed by uneven stress distribution when the

product was operated with off-centered fittings. Contact our service
representatives.

Piston action is slow or "spongy":

A. There is air in the hydraulic system.  Follow steps on page 14 to expel any

air in the system.

B. Insufficient hydraulic fluid.  Follow steps on page 14 to add fluid.

C. The battery power level is running low. Charge the battery cartridge.

Charging Lamp does not light up:

A. Dust, etc. is obstructing the battery terminals. Clean the battery.

B. Battery cartridge is overheated or too cold (below 0

°

C). Allow the cartridge

to cool before charging.

Reviews: