Nemesis Audio
9
word clock signal only (internally selectable via P1-3 and P1-4). This helps to ensure any switching
clicks or bangs are as predictable as possible, and in the case of a fast-acting mute on the receiving
device can remove them all together. If a word clock signal is not fed to the unit it will schedule a
switchover whenever the button is pressed, which could cause data corruption at any frame position
in the stream and may result in multiple channels suffering clicks/bangs etc. It should be noted this
will not be any worse than any other MADI switching solution which doesn’t rely on clock edge
switching.
Because all data remains in its native format the unit is able to switch all sample rates and MADI
formats, as well as proprietary control and MIDI data, and is compatible with double rate/S-MUX
data streams etc.