THE WATER IN THE BOILER AND/OR BOWL OVERHEATS 

 

POSSIBLE CAUSE 

SPECIFIC SOLUTION 

 

The  contacts  in  the  boiler  and/or  bowl  thermostat 
are locked in the “Closed” position. 

 

Replace; 

 

The  relay  has  remained  in  the  “Closed 
position”,even though voltage is supplied to the coil. 

 

Check the closure contacts and replace if 
necessary; 

 

THE WASH ELECTRIC PUMP IS FAULTY 

 

POSSIBLE CAUSE 

SPECIFIC SOLUTION 

 

The thermal protection is disconnected; 

 

The door micro is faulty; 

 

The condenser is faulty: 

 

The motor winding is faulty. 

 

Electronic board

 

 

 

Replace; 

 

Replace; 

 

Replace; 

 

Replace; 

 

Check  connection  and  in  case  replace 
the board 

 

The  rotor  does  not  rotate  properly  and  absorption 
exceeds the nominal values; 

 

 

 

 

The motor rotor is blocked; 

 
 
 

 

There is insufficient water in the bowl; 

 
 
 

 

The pump suction filter is dirty; 

 
 
 

 

The pump and the washing impellers are dirty. 

 

Remove  and  clean  the  coil  and  replace 
the seal and the bearings. Check that the 
motor  has  been  set  at  the  system 
voltage.  Remove  any  residues.  Check 
that all phases are present; 

 

Make  sure  that  there  are  no  large  food 
deposits  or  cutlery  in  the  body  of  the 
pump.  Make  sure  that  the  mechanical 
seal and shaft bearings are not blocked; 

 

Make  sure  that  the  overflow  is  perfectly 
tightened.  Make  sure  that  the  pressure 
switch  prevents  water  from  entering  the 
bowl at 1 cm from the overflow level; 

 

Make  sure  that  the  dishes  are  placed  in 
the dishwasher only after they have been 
properly  cleaned.    Clean  the  filter 
regularly according to its use; 

 

Make  sure  that  the  machine  is  not  used 
without a filter or that the filter is perfectly 
inserted in its housing.  

 

THE MACHINE DOES NOT RINSE 

 

POSSIBLE CAUSE 

SPECIFIC SOLUTION 

 

There is no water in the system; 

 

The tap is partially closed; 

 

The supply pipe may be bent or squeezed; 

 

The filter of the solenoid valve may be dirty; 

 

The coil of the solenoid valve may be interrupted; 

 

The  small  piston  of  the  solenoid  valve  may  be 
blocked; 

 

Pressure in the system is insufficient. 

 

Check; 

 

Check; 

 

Check; 

 

Remove and clean; 

 

Replace; 

 

Remove and check; 

 

 

Make sure that the system pressure is at 
least 2 bar. If pressure is lower, install an 
auxiliary rinse pump; 

 
 

Summary of Contents for SC40A

Page 1: ...INSTALLATION USE AND MAINTENANCE MANUAL GLASSES WASHERS FRONT LOADING DISH WASHER...

Page 2: ...CHECKS 8 10 1 RINSE AID DISPENSER 8 10 2 LOADING THE DETERGENT 9 11 DISPENSER FOR LIQUID DETERGENT optional 9 11 1 START UP 9 11 2 OPERATION 10 11 3 HOW TO REGULATE THE DETERGENT DISPENSER 10 11 4 EX...

Page 3: ...d liable for any of the following instances improper use of the appliances improper installation performed without complying with the procedures contained herein faulty electrical power 3uppl serious...

Page 4: ...Total cycle time sec 120 Production baskets hour 30 Tub capacity in lt 8 Boiler capacity in lt 4 5 Consumption of water per cycle l 2 2 Tub power kW 1 2 Boiler power kW 2 2 Wash pump power kW 0 2 Pow...

Page 5: ...Wash pump power kW 0 35 Power rinse pump kW 0 33 Total power kW 3 35 Water supply temperature C 50 Water hardness F 10 16 16 10 16 16 Pressure bar 2 4 4 2 4 4 Power voltage 230 V 1N Frequency 50 Hz S...

Page 6: ...kW 4 5 Wash pump power kW 0 65 Power rinse pump kW 0 33 Total power kW 5 15 Water supply temperature C 15 55 Water hardness F Pressure bar 2 4 3 4 2 4 3 4 Power voltage 230V 1 _ 230V 3 _ 400 V 3 N Fr...

Page 7: ...e is installed c read all the indications given in this handbook carefully as they provide important information for safe installation use and maintenance d keep this handbook in a safe place for futu...

Page 8: ...of the electric system which may have become loose during storage or transport ATTENTION Safety device installed The appliances are equipped with a manual reset safety device which in the event of an...

Page 9: ...er 10lt of rinse water and to a water hardness of 10 12 F Given that 1g of product 1cm is equal to 8 cm in the liquid column inside the transparent suction tublet the indicative amounts for the variou...

Page 10: ...amount of detergent recommended by the manufacturer for every litre of wash water taken from the product technical sheet 3 gr of detergent Given that 1 gr 1 cc of detergent takes up 8 cm of the transp...

Page 11: ...ined the load solenoid valve must start operating again when the water level is 2 cm above the heating element 2 CHECKING THE RINSE CYCLE The rinse arms must rotate freely and all the sprayers must wo...

Page 12: ...OFF SWITCH 3 CYCLE START BUTTON FOR EQUIPMENT WITH DRAINING PUMP 4 OPERATING MACHINE INDICATOR YELLOW LIGHT 5 READY MACHINE INDICATOR YELLOW LIGHT 6 SHORT CYCLE 1 LONG CYCLE 2 SWITCH 7 CYCLE START RE...

Page 13: ...and hygienically safe In order to avoid wasting these efforts make sure that crockery is stored in areas having the same requisites 16 DECALCIFICATION AND REGENERATION OF RESINS Some dishwasher models...

Page 14: ...e regeneration cycle 18 ADVICE TO USERS 18 1 PERIODIC MAINTENANCE Disconnect the appliance from the power supply before carrying out any cleaning or maintenance operations Remove the washing impellers...

Page 15: ...FAULTY L THE REGENERATION CYCLE DOES NOT START M THE DRAINAGE PUMP IS FAULTY Once the area where the anomaly has presumably occurred has been identified proceed as indicated in the tables below A BY S...

Page 16: ...thermostat may be faulty The bowl thermostat may be faulty The safety thermostat may be faulty The pressure switch contact may be faulty The safety thermostat has failed to cut in The connections or...

Page 17: ...Remove any residues Check that all phases are present Make sure that there are no large food deposits or cutlery in the body of the pump Make sure that the mechanical seal and shaft bearings are not...

Page 18: ...The electric pump may be faulty or damaged The detergent is not suited to dishwashers There is no detergent in the bowl The impellers may be obstructed or damaged The washing impeller may be blocked...

Page 19: ...nufacturer Once the dispenser has been adjusted it is necessary to wait until the product concentration has stabilised on the new values after a few wash cycles before being able to notice any improve...

Page 20: ...ce the pressure switch Check the connection and if necessary replace the board The manufacturer declines all responsibility for any incorrect information herein due to printing or spelling mistakes Th...

Page 21: ...21 Copper electric system PA Nylon wash circuit...

Page 22: ...22 21 INSTALLATION DIAGRAMS...

Page 23: ...23...

Page 24: ...24...

Page 25: ...25 22 DECLARATION OF CONFORMITY...

Reviews: