10FC nozzle and 2TN nozzle flow rates with changes in pressure
5
the performance data in this section has been recorded under ideal test conditions and may be adversely affected by poor hydraulic entrance conditions, slope, riser tilt,
temperature, wind or other factors.
Always be sure:
to use the nozzle size that is recommended for the plate. the operating pressure is within the recommended range.
Only the nozzle and plate combinations grouped together in the above chart are recommended. the absence of flow data on the above chart indicates the pressure is
outside the recommended range.
R10 Plate/Nozzle options and Flow Performance in GPM and LPH
R10 Turbo Plate/Nozzle options and Flow Performance in GPM and LPH
Plate
Plate
Recommended
PSI
BAR
Series
Options
Nozzles
25
30
35
40
45
50
1.75
2
2.25
2.5
2.75
3
3.25
P2
P2 9° Red
Lt. Blue #40
—
—
.28
.30
.32
.34
—
—
61.4
64.7
68.0
71.3 74.6
radius 18-20’
(5.5-6.1 m)
Lt. Purple #45
.29
.32
.35
.37
—
—
66.4
71.3
76.3
80.6
83.9
—
—
Stream Ht.15-20”
(38-51 cm)
Dk. Green #50
.36
.39
.43
.46
—
—
82.3
87.2
93.4
99.4
104
—
—
.35 10Fc
P4
P4 9° white
Dk. Green #50
—
—
.43
.46
.48
.51
—
—
93.4
99.4
104
108
112
radius 18-22’
(5.5-6.7 m)
Lt. Yellow #55
.44
.48
.52
.55
—
—
101
107
114
120
125
—
—
Stream Ht. 13-21”
(33-53 cm)
Lt. red #60
.51
.56
.61
.65
—
—
117
125
133
141
147
—
—
.50 10Fc
P6
P6 9° Blue
Gray #65
.61
.67
.72
.77
—
—
140
150
158
166
175
—
—
radius 19-21’
(5.8-6.4 m)
White #70
.70
.77
.83
.89
—
—
160
172
182
192
202
—
—
Stream Ht. 17-21”
(43-53 cm)
Dk. Blue #78
.88
.97
1.05
—
—
—
201
217
230
242
—
—
—
.75 10Fc
.35 10 Fc flow control nozzles are flow regulating within a flow range of no more than 0% greater and 10% less than
the nominal flow — .35 GPM
(79.5 LPH)
.
.50 10 Fc flow control nozzles are flow regulating within a flow range of no more than 0% greater and 10% less than
the nominal flow — .50 GPM
(114 LPH)
.
.75 10 Fc flow control nozzles are flow regulating within a flow range of no more than 0% greater and 10% less than
the nominal flow — .75 GPM
(170 LPH)
.
1.25 10 Fc flow control nozzles are flow regulating within a flow range of no more than 3.5% greater and 8% less than
the nominal flow — 1.25 GPM
(284 LPH).
use above 30 PSI
(2 bAR)
.
1.5 10 Fc flow control nozzles are flow regulating within a flow range of no more than 3.5% greater and 8% less than
the nominal flow — 1.5 GPM
(341 LPH).
use above 30 PSI
(2 bAR)
.
1.0 10 Fc flow control nozzles are flow regulating within a flow range of no more than 3.5% greater and 8% less than
the nominal flow — 1.0 GPM
(227 LPH).
use above 30 PSI
(2 bAR)
.
1.0 10 Fc flow control nozzles are flow regulating within a flow range of no more than 3.5% greater and 8% less than
the nominal flow — 1.0 GPM
(227 LPH).
use above 30 PSI
(2 bAR)
.
for use with P8 24° plate only
for use with P8 24° plate only
.75 10 Fc flow control nozzles are flow regulating within a flow range of no more than 0% greater and 10% less than
the nominal flow — .75 GPM
(170 LPH)
.
Plate
Plate
Recommended
PSI
BAR
Series
Options
Nozzles
25
30
35
40
45
50
1.75
2
2.25
2.5
2.75
3
3.25
P6
P6 9° Blue
Gray #65
.61
.67
.72
.77
.82
.86
140
150
158
166
175
183
190
r.20-22’
(6.1-6.7 m)
Stream Ht. 17-23”
White #70
.70
.77
.83
.89
.94
1.00
160
172
182
192
202
210
219
(43-58 cm)
Dk. Blue #78
.88
.97
1.05 1.12
1.19
1.25
201
217
230
242
254
266
276
.75 10Fc
P6 15° Purple
r. 25-26’
(7.6-7.9 m)
Stream Ht. 34-40”
1.0 10Fc
(86-102 cm)
P8
P8 15° gold
Orange #86
1.07 1.17 1.27 1.36
1.45
1.53
245
261
278
294
308
323
337
r. 26-30’
(7.9-9.1 m)
Stream Ht. 36-42”
Purple #94
1.27 1.39 1.50 1.61
1.70
1.80
290
311
329
347
365
380
396
(91-106 cm)
Yellow #102
1.50 1.64 1.78 1.90
2.02
2.13
343
366
389
411
431
451
469
1.25 10Fc
P8 24° Brown
r. 27-33’
(8.2-10.1 m)
1.5 10 Fc
Stream Ht. 62-89”
(157-226 cm)
Dk. Blue #78
—
.97
1.05 1.12
1.19
1.25
—
217
230
242
254
266
276
1.0 10FC