background image

 

NW511

 

11

 

 
 

Key

 

to

 

single

phase/three

phase

 

electrical

 

system

 

diagram

 

 

 

NTCB

 

Boiler

 

temperature

 

probe

 

 

 

 

EVA

 

Aquastop

 

solenoid

 

valve

 

NTCV

 

Tank

 

temperature

 

probe

 

 

 

 

EVR

 

Regeneration

 

solenoid

 

valve

  

SDET

 

Detergent

 

sensor

 

 

 

 

 

EVS

 

Brine

 

discharge

 

solenoid

 

valve

 

SBRIL

 

Rinse

 

aid

 

sensor

 

 

 

 

 

PB

 

Rinse

 

aid

 

peristaltic

 

pump

  

SFIL

 

Filter

 

sensor

 

 

 

 

 

 

PD

 

Detergent

 

peristaltic

 

pump

  

FLMT

 

Flowmeter

  

 

 

 

 

 

EVF

 

Filler

 

solenoid

 

valve

 

SS

   

Salt

 

sensor

 

 

 

 

 

 

PS

 

Drain

 

pump

 

RD

   

Door

 

sensor

 

 

 

 

 

 

PLB

 

Boiler

 

pressure

 

switch

  

PR

   

Rinsing

 

pump

   

 

 

 

 

PLV

 

Tank

 

level

 

pressure

 

switch

  

PL

   

Washing

 

pump

   

 

 

 

 

PSV

 

Tank

 

safety

 

pressure

 

switch

  

PLB

  

Boiler

 

level

 

pressure

 

switch

 

 

 

 

AQS

 

Aquastop

 

microswitch

 

THB

 

Boiler

 

safety

 

thermostat

 

 

 

 

SB

 

Motherboard

  

M

   

Terminal

 

board

  

 

 

 

 

SI

 

Interface

 

board

 

LF

   

RFI

 

filter

 

 

 

 

 

 

TM

 

Terminal

 

board

 

ground

 

FUSE

 

Mains

 

fuse

 

 

 

 

 

 

TV

 

Tank

 

ground

 

CB

   

Boiler

 

contactor

 

 

 

 

 

TF

 

RFI

 

filter

 

ground

 

RB

   

Boiler

 

heating

 

element

   

 

 

 

TPL

 

Washing

 

pump

 

ground

 

T

FU

 

Overtemperature

 

fuse

   

 

 

 

TPR

 

Rinsing

 

pump

 

ground

 

THRV

 

Tank

 

safety

 

thermostat

  

 

 

 

TRV

 

Tank

 

heating

 

element

 

ground

 

RV

   

Tank

 

heating

 

element

   

 

 

 

TB

 

Boiler

 

heating

 

element

 

ground

  

Figure

 

 

Appliance

 

three

phase

 

electrical

 

system

 

diagram

 

 

 

 

Summary of Contents for NW511

Page 1: ...PROFESSIONAL DISHWASHER...

Page 2: ...ocedure 15 5 4 Modifiable parameters 16 5 5 Alarm trigger time thresholds 16 5 6 Adjusting detergent and rinse aid dispensing 17 5 7 Adjusting the regeneration frequency models with softener only 18 5...

Page 3: ...e instructions in this manual carefully to become familiar with the right conditions for the proper use of your warewasher TECHNICAL INSTRUCTIONS These are intended for the qualified staff who are to...

Page 4: ...E OF NON ORIGINAL SPARE PARTS THIS APPLIANCE IS MARKED AS REQUIRED BY EU DIRECTIVE 2002 96 EC WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT WEE BY MAKING SURE THAT THIS PRODUCT IS DISPOSED OF CORRECTLY TH...

Page 5: ...NEVER USE THE WAREWASHER OR ANY PART OF IT AS A LADDER SUPPORT OR STAND FOR PEOPLE ANIMALS OR ANY OBJECT LEANING OR SITTING ON THE OPEN DOOR OF THE WAREWASHER MIGHT CAUSE IT TO TIP OVER PUTTING PEOPLE...

Page 6: ...0 8 Water intake pressure kPa bar 100 600 1 6 Water intake temperature C 15 C 60 C Intake water hardness models with softener f 15 f 60 f Rinse cycle water consumption l 3 2 Boiler capacity l 6 Tank...

Page 7: ...NW511 7 CAVITY DIMENSIONS FOR BUILT UNDER INSTALLATION APPLIANCE DIMENSIONS AND CONNECTION POSITIONS N B VALUE 1000 WITH ASTERISK max 600 if siphon with valve is used...

Page 8: ...ally dangerous All packaging materials used are environment friendly They can be kept without constituting any hazard or may be disposed of at a specialist waste disposal centre The plastic components...

Page 9: ...liance so do not install it behind the warewasher The stated cycle duration applies to appliances supplied with hot water 50 C 60 C If the warewasher is supplied with cold water the cycle duration mig...

Page 10: ...ance only The user must have a master switch and a differential safety breaker with rating suitable for the appliance s characteristics installed on the electricity supply line in accordance with the...

Page 11: ...ler pressure switch PR Rinsing pump PLV Tank level pressure switch PL Washing pump PSV Tank safety pressure switch PLB Boiler level pressure switch AQS Aquastop microswitch THB Boiler safety thermosta...

Page 12: ...NW511 12 Figure 1 Appliance single phase electrical system diagram...

Page 13: ...the filters onto their ends as shown If the detergent dispenser is not factory fitted it can be retrofitted after ordering the relative kit As an alternative an external dispenser can be fitted making...

Page 14: ...ever the type of detergent or rinse aid is changed it is ABSOLUTELY ESSENTIAL to flush out the peristaltic pumps by placing the external intake pipes in water for a few cycles Always use only products...

Page 15: ...e probe but due to the thermal inertia of the probe or its seat wait about 1 minute after the heating element power absorption reading to obtain the real temperature 5 3 Parameter programming procedur...

Page 16: ...off 1 on M P5 Soft Start option 01 0 off 1 on M P6 Boiler temperature offset 00 Real measured Offset M P7 Tank temperature offset 04 Real measured Offset M P8 Real temperature display 01 0 filtered 1...

Page 17: ...kwise and increased by turning clockwise RB Rinse aid dispensing regulator screw Adjustments are made using the adjuster screw AS SHOWN The quantity dispensed is reduced by turning clockwise and incre...

Page 18: ...ver 60 dF an external water treatment device must be used and the regeneration frequency must be set at H00 5 9 Table of parameters This table shows the relationship between the intake water hardness...

Page 19: ...eck dynamic pressure in intake system clean water intake filter If the problem persists tank pressure switch has failed continuous empty reading leak from pipe connected to air trap drain siphon block...

Page 20: ...asher with a basin and disconnect it from the electrical mains Unscrew the screw A release the tang B and lift it Check that the impeller of the drain pump underneath the cover turns freely and is fre...

Page 21: ...generation key only if softener is fitted L1 power on LED L2 pump out in progress LED L3 regeneration LED flashing regeneration request L4 no salt LED only if softener is installed Short cycle key Med...

Page 22: ...ser device Failure to comply with this recommendation leads to forfeiture of the warranty entitlement on the appliance s water system Industrial warewasher detergents may cause serious irritation Comp...

Page 23: ...ait at least 30 before moving on to the next phase to give the tank time to reach the correct washing temperature Load the dishes or glasses and close the door Select the programme required by pressin...

Page 24: ...turned off the appliance sets on the last cycle performed To change it press the key of the program required the light comes on To confirm hold down for about 2 The LED starts to flash and the washing...

Page 25: ...sts about 15 after which the appliance switches off automatically Resin regeneration for models with water softener Once the number of washing cycles set during installation has been completed as indi...

Page 26: ...ialist technician twice a year The internal pipe of the detergent peristaltic pump should be checked and or replaced by the After Sales Service every 12 months or 15 000 wash cycles and operation of t...

Page 27: ...might cause damage Reassemble the spray arms with care TOP SPRAY ARMS BOTTOM SPRAY ARMS 3 1 2 Clean the outside of the appliance with a damp cloth and neutral soap rinsing and drying thoroughly 8 3 Le...

Page 28: ...ity of detergent No or not enough detergent or rinse aid being supplied detergent or rinse aid not being taken from the relative container Check that the intake filter is not fouled If you are unable...

Page 29: ...uitable for the type of mains water If the problem persists contact the after sales service WATER IN TANK AFTER PUMP OUT Drain hose incorrectly positioned or partially obstructed Check that the warewa...

Page 30: ...f wait 15 and back on and perform another cycle if the problem persists call the after sales service E 5 Tank overheating Switch the warewasher off wait 15 and back on and perform another cycle if the...

Page 31: ...ists call the after sales service E 8 Tank heating malfunction does not heat up Switch the warewasher off and back on and perform another cycle if the problem persists call the after sales service E 9...

Page 32: ...le to provide you with guidance about keeping your appliance functioning correctly and put you in touch with your nearest authorised Service Centre 020 8993 6198 Our whole product offering can be view...

Reviews: