NELCO CONTACT AB
7
Maintenance
Keep the pump free of dirt and metal chips. Use a lubricant to
clean the tool when necessary.
Routine renewal of pump oil is required. Particles mixed in the pump
oil is the most common cause of product failure.
Do
NOT
lift the pump by the hydraulic hose or couplers, or let the
pump drop to the ground or into the carrying case.
Do
NOT
keep this product in places with high temperatures, high
humidity, or direct sunlight.
Suggested working temperatures
:
-10°C ~ 40°C. Check hydraulic
fluid specifications.
Hydraulic fluid temperatures over 65°C might soften packings and
seals and cause fluid leaks.
The hydraulic fluid pressure should only be adjusted by
NELCO
service representatives
.
Inform
NELCO
authorized distributors in case of any abnormalities
or malfunctions of the product.
DO NOT DISASSEMBLE OR ATTEMPT TO REPAIR THIS PUMP.
ATTENTION
• Turn off the power and release
pressure before cleaning the tool
head or pump.
• If you notice a leak on the pump, hose
or tool head, do not use your hands
to look for the leak.